Your browser doesn't support javascript.
loading
Central Macular Thickness in a Healthy Mexican Population Using Huvitz Optical Coherence Tomography.
García-Franco, Renata; Méndez-Marín, Dalia; García-Roa, Marlon; Ramirez-Neria, Paulina; Valera-Cornejo, Diego; Lansingh, Van Charles.
Afiliación
  • García-Franco R; Retina department, Instituto Mexicano de Oftalmología I.A.P., Santiago De Querétaro, Querétaro, México.
  • Méndez-Marín D; Retina department, Instituto Mexicano de Oftalmología I.A.P., Santiago De Querétaro, Querétaro, México.
  • García-Roa M; Retina department, Instituto Mexicano de Oftalmología I.A.P., Santiago De Querétaro, Querétaro, México.
  • Ramirez-Neria P; Retina department, Instituto Mexicano de Oftalmología I.A.P., Santiago De Querétaro, Querétaro, México.
  • Valera-Cornejo D; Retina department, Instituto Mexicano de Oftalmología I.A.P., Santiago De Querétaro, Querétaro, México.
  • Lansingh VC; Retina department, Instituto Mexicano de Oftalmología I.A.P., Santiago De Querétaro, Querétaro, México.
Clin Ophthalmol ; 14: 3931-3940, 2020.
Article en En | MEDLINE | ID: mdl-33235432
ABSTRACT

OBJECTIVE:

To determine normal macular thickness values in a healthy Mexican population and its variation by age and gender using Huvitz spectral-domain optical coherence tomography (HOCT-1F).

METHODS:

This cross-sectional study included 211 consecutive eyes from clinically normal subjects (66 men, 145 women) between October 2018 and December 2018, with best-corrected visual acuities better than 20/30. One eye was selected for the macular scan using the Huvitz OCT (Huvitz OCT-1F, HOCT-1F, Huvitz Co., Ltd., Republic of Korea) with an automated segmentation algorithm. Three vertical and horizontal scans, centered on the fovea with an area of 9 mm, and a color 45° fundus photograph were obtained using Huvitz OCT-1F. Macular measurements were presented as means with standard deviations values for each of the nine regions defined by the Early Treatment Diabetic Retinopathy Study (ETDRS).

RESULTS:

The mean age was 34.3±11.9 years. Using the ETDRS map, the mean central subfield thickness (CST) was 227.4±18.9 µm. Male gender was associated with greater CST (P<0.001) compared to females. There was no association between mean macular CST (r2=0.011; P=0.11) and age. Macular thickness was thicker in the inner ring than in the outer ring, and there were no significant differences in mean CST among age groups (P=0.70).

CONCLUSION:

Normal macular thickness values using the Huvitz OCT in a Mexican healthy population aged from 18-70 years were thinner in the foveal macular region than values reported in other populations. Female patients had a thinner CST, and age was not correlated with macular thickness.