COMPARISON OF INTRAOCULAR PRESSURE MEASUREMENT USING REBOUND AND APPLANATION TONOMETRY IN LOGGERHEAD (CARETTA CARETTA) SEA TURTLES.
Lamagna, Barbara; Affuso, Andrea; Micieli, Fabiana; Mennonna, Giuseppina; Meomartino, Leonardo; Valle, Giovanni Della; Ciampa, Mariapia; Treglia, Gianluca; Hochscheid, Sandra.
Afiliación
  • Lamagna B; Department of Veterinary Medicine and Animal Production, University of Napoli Federico II, Napoli, Italy.
  • Affuso A; Marine Turtle Research Center, Stazione Zoologica Anton Dohrn, 80055 Portici, Italy.
  • Micieli F; Department of Veterinary Medicine and Animal Production, University of Napoli Federico II, Napoli, Italy, fabiana.micieli@unina.it.
  • Mennonna G; The Interdepartmental Centre of Veterinary Radiology, 80137 Naples, Italy.
  • Meomartino L; The Interdepartmental Centre of Veterinary Radiology, 80137 Naples, Italy.
  • Valle GD; Department of Veterinary Medicine and Animal Production, University of Napoli Federico II, Napoli, Italy.
  • Ciampa M; Marine Turtle Research Center, Stazione Zoologica Anton Dohrn, 80055 Portici, Italy.
  • Treglia G; Marine Turtle Research Center, Stazione Zoologica Anton Dohrn, 80055 Portici, Italy.
  • Hochscheid S; Marine Turtle Research Center, Stazione Zoologica Anton Dohrn, 80055 Portici, Italy.
J Zoo Wildl Med ; 52(2): 604-609, 2021 Jun.
Article en En | MEDLINE | ID: mdl-34130403
ABSTRACT
This study aimed to evaluate intraocular pressure (IOP) estimates in healthy eyes of Caretta caretta using rebound tonometry in comparison with applanation tonometry. Twenty-three healthy C. caretta (housed at the Marine Turtle Research Center) without preexisting ophthalmic disease were enrolled in the study. IOP measurements were obtained by the same ophthalmologist, with the turtle in ventral recumbency between 230 p.m. and 430 p.m., using a rebound tonometer (RT; TonoVet) in dog calibration mode, and after topical anesthesia, an applanation tonometer (AT; Tono-Pen) in both eyes. The average of three readings per instrument was used for analysis. The agreement between the two tonometers was assessed by Bland-Altman analysis and intraclass correlation coefficient (ICC). Moreover, differences in IOP between the two tonometers were analyzed using the Mann-Whitney test. Moderate agreement was found between the two tonometers (ICC, 0.663; 95% confidence interval, 0.206-0.857). The median, Q1, and Q3 IOP obtained with AT (6.2, 4.7, and 9.1 mm Hg) were significantly lower (P = 0.001) than that obtained with RT (9.7, 8.3, and 11.6 mm Hg). It was not possible to obtain an instrument automatically generated mean of four values with AT because of retraction of the globe by the animals, and IOP measurement was unsuccessful in 7 eyes. In conclusion, IOP readings from the RT were statistically higher than those from the AT. RT proved to be more feasible because of the light, short-lasting contact with the cornea.