Your browser doesn't support javascript.
loading
Differentiation of Benign and Malignant Parotid Gland Tumors with MRI and Diffusion Weighted Imaging.
Orhan Soylemez, Umut Percem; Atalay, Basak.
Afiliación
  • Orhan Soylemez UP; Istanbul Medeniyet University Faculty of Medicine Goztepe Training and Research Hospital, Department of Radiology, Istanbul, Turkey.
  • Atalay B; Istanbul Medeniyet University Faculty of Medicine, Goztepe Training and Research Hospital, Department of Radiology, Istanbul, Turkey.
Medeni Med J ; 36(2): 138-145, 2021.
Article en En | MEDLINE | ID: mdl-34239766
OBJECTIVE: This study investigated the effectivity of Magnetic Resonance Imaging (MRI) findings and Apparent Diffusion Coefficient (ADC) value in evaluating parotid gland tumors (PGTs), and aimed to reduce the biopsy procedure before surgery. METHODS: This retrospective study included 54 PGTs of 42 patients' (24 female, 18 male, mean age; 51.4±15.9). All of the patients had an MRI, and histopathologic diagnosis. The signal intensity [T1 and T2 Weighted (W), T1W after intravenous contrast agent injection] and mean ADC values of the PGTs were measured. Also contrast enhancement pattern (homogenous, heterogeneous, peripheral or none), margin features (well or ill-defined), sizes, location (superficial lobe/deeplobe/both), perineural spread, presence of lymphadenopathy, and extension to adjacent structures were noted. RESULTS: The distribution of PGTs was; 21 pleomorphic adenomas, 18 Warthin tumors, 2 lymph nodes, 2 mucoepidermoid carcinomas, 5 adenoid cystic carcinoma, 1 basal cell carcinoma,2 metastases and 2 lymphomas; (13 malignant and 41 benign lesions). Morphologic parameters; ill-defined margin, perineural spread, lymphadenopathy, and extension to adjacent structures were found to be significantly associated with malign lesions (p<0.01). There was a significant difference between ADC values of malignant and benign PGTs (p<0.05). Also ADC values and T2 signal intensity was significantly lower in Warthin tumors rather than pleomorphic adenomas (p<0.05). CONCLUSIONS: Mean ADC values when considered with morphological features may be accessible methods to distinguish benign and malignant PGTs, also ADC values and T2 signal intensity may be useful for differentiating pleomorphic adenomas from Warthin tumors, thereby reducing the number of biopsies and thus complications.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Tipo de estudio: Observational_studies / Risk_factors_studies Idioma: En Revista: Medeni Med J Año: 2021 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Tipo de estudio: Observational_studies / Risk_factors_studies Idioma: En Revista: Medeni Med J Año: 2021 Tipo del documento: Article