Your browser doesn't support javascript.
loading
A study into the viability of Synbone® as a proxy for Sus scrofa (domesticus) ribs for use with 7.62 × 51 mm Full Metal Jacket ammunition in ballistic testing.
Pullen, Amy E; Kieser, David C; Hooper, Gary; Plummer, Thomas C H.
Afiliación
  • Pullen AE; Department of Orthopaedics and Musculoskeletal Medicine, Christchurch School of Medicine, University of Otago, PO Box 4545, 8140, Christchurch, New Zealand. a.pullen@dta.mil.nz.
  • Kieser DC; Department of Orthopaedics and Musculoskeletal Medicine, Christchurch School of Medicine, University of Otago, PO Box 4545, 8140, Christchurch, New Zealand.
  • Hooper G; Department of Orthopaedics and Musculoskeletal Medicine, Christchurch School of Medicine, University of Otago, PO Box 4545, 8140, Christchurch, New Zealand.
  • Plummer TCH; DAD Kauri Point, New Zealand Defence Force, Onetaunga Rd, Chatswood, Auckland, 0626, New Zealand.
Forensic Sci Med Pathol ; 17(4): 665-669, 2021 12.
Article en En | MEDLINE | ID: mdl-34495451
ABSTRACT
Forensic reconstructions and ballistic testing requires the use of consistent and repeatable simulants. Synthetic bone has been developed to be mechanically similar to human bone; however, it does not have the same viscoelastic properties. Bone acts as brittle and stiff material and fails instantly under high-energy events such as ballistic impacts. Consequently, bone simulants for use in ballistic testing should show comparable energy deposition to mammalian bones. This study aims to determine if Synbone® flat plates could be a viable proxy for Sus scrofa (domesticus) ribs in ballistic testing with 7.62 × 51 mm Full Metal Jacket ammunition. 5 mm, 6 mm and 12 mm quartered Synbone® plates were embedded into 10% ballistic gelatin and shot using 7.62 mm ammunition. The models were then analysed to compare the Synbone® to a previous Sus Scrofa (domesticus) rib study and focused on energy deposition, the number of fragments within the block, angle of deviation, onset of yaw, the temporary cavity, and the permanent wound channel. No significant difference was seen between the Sus Scrofa (domesticus) and the 5 mm Sybone®. There were significant differences observed between Sus Scrofa (domesticus) ribs and 6 mm Synbone® for the number of fragments, energy deposition and projectile tract diameter, and significant differences seen between Sus scrofa (domesticus) ribs and 12 mm Synbone® for the depth of onset of yaw, energy deposition and projectile tract diameter. This study indicates that the 5 mm Synbone® plate is a suitable proxy for Sus scrofa (domesticus) ribs for use with 7.62 × 51 mm FMJ ammunition in ballistic testing.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Heridas por Arma de Fuego / Sus scrofa Idioma: En Revista: Forensic Sci Med Pathol Asunto de la revista: JURISPRUDENCIA / MEDICINA / PATOLOGIA Año: 2021 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Heridas por Arma de Fuego / Sus scrofa Idioma: En Revista: Forensic Sci Med Pathol Asunto de la revista: JURISPRUDENCIA / MEDICINA / PATOLOGIA Año: 2021 Tipo del documento: Article