Your browser doesn't support javascript.
loading
Comparison of susceptibility-weighted angiography (SWAN) and T2 gradient-echo sequences for the detection of acute cerebral venous thrombosis.
Boukobza, Monique; Guinebert, Sylvain; Laissy, Jean-Pierre.
Afiliación
  • Boukobza M; Department of Radiology, Bichat Hospital, 55076Assistance Publique-Hôpitaux de Paris, Paris, France.
  • Guinebert S; Department of Adult Radiology, 26930Hôpital Necker, Paris, France.
  • Laissy JP; Department of Radiology, Bichat Hospital, 55076Assistance Publique-Hôpitaux de Paris, Paris, France.
Neuroradiol J ; 36(2): 148-157, 2023 Apr.
Article en En | MEDLINE | ID: mdl-35722681
ABSTRACT

OBJECTIVES:

To assess the diagnostic accuracy and lesion conspicuity of susceptibility-weighted angiography (SWAN) and T2* for the clot detection in acute cerebral venous thrombosis (CVT) by comparison with contrast-enhanced MR venography.

METHODS:

Venous thrombi detection and conspicuity were assessed by two readers for 18 venous segments on both T2*, SWAN source images, 2D SWAN reformats matching with T2*, and 3D SWAN images (SWAN-MinIP). Images obtained with the three reading techniques were systematically scored and compared to CE MRV findings, in a blinded fashion, per patient and per segment, and compared to each other.

RESULTS:

In 30 patients, 137 thrombosed venous segments were evaluated. The sensitivity of T2*, SWAN source images, 2D SWAN, and SWAN MinIP were, respectively, of 89.3%/82.1%, 82.1%, and 82.1% for dural sinus thrombosis and of 100%/100%/100%/96.6% for cortical venous thrombosis. There were significant differences in thrombus detection between T2* and SWAN T2* versus SWAN source images and 2D SWAN (p = 0.04) and versus SWAN MinIP (p = 0.03). There were no significant differences between the three modalities of SWAN images. T2* was more sensitive than all SWAN images for both sigmoid sinus thrombosis and intracranial internal jugular vein thrombosis (p = 0.04). Inter-observer agreement was slightly superior with T2* (p < 0.05).

CONCLUSION:

In this small cohort, SWAN sequence at 3T did not yield additional value for thrombus detection in acute CVT compared to T2*. This study highlights SWAN's greatest weakness both for diagnostic accuracy and lesion conspicuity compared to T2* for acute venous clot detection near the skull base.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Trombosis de los Senos Intracraneales / Trombosis / Trombosis de la Vena / Trombosis Intracraneal Tipo de estudio: Diagnostic_studies Idioma: En Revista: Neuroradiol J Año: 2023 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Trombosis de los Senos Intracraneales / Trombosis / Trombosis de la Vena / Trombosis Intracraneal Tipo de estudio: Diagnostic_studies Idioma: En Revista: Neuroradiol J Año: 2023 Tipo del documento: Article