Your browser doesn't support javascript.
loading
Development and Analytical Validation of a One-Step Five-Plex RT-ddPCR Assay for the Quantification of SARS-CoV-2 Transcripts in Clinical Samples.
Strati, Areti; Zavridou, Martha; Paraskevis, Dimitrios; Magiorkinis, Gkikas; Sapounas, Spyros; Lagiou, Pagona; Thomaidis, Nikolaos S; Lianidou, Evi S.
Afiliación
  • Strati A; Lab of Analytical Chemistry, Department of Chemistry, National and Kapodistrian University of Athens, 15771 Athens, Greece.
  • Zavridou M; Lab of Analytical Chemistry, Department of Chemistry, National and Kapodistrian University of Athens, 15771 Athens, Greece.
  • Paraskevis D; Department of Hygiene, Epidemiology and Medical Statistics, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece.
  • Magiorkinis G; Department of Hygiene, Epidemiology and Medical Statistics, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece.
  • Sapounas S; National Public Health Organization, 15123 Athens, Greece.
  • Lagiou P; Department of Hygiene, Epidemiology and Medical Statistics, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece.
  • Thomaidis NS; Lab of Analytical Chemistry, Department of Chemistry, National and Kapodistrian University of Athens, 15771 Athens, Greece.
  • Lianidou ES; Lab of Analytical Chemistry, Department of Chemistry, National and Kapodistrian University of Athens, 15771 Athens, Greece.
Anal Chem ; 94(36): 12314-12322, 2022 09 13.
Article en En | MEDLINE | ID: mdl-35960711
ABSTRACT
Highly sensitive methodologies for SARS-CoV-2 detection are essential for the control of COVID-19 pandemic. We developed and analytically validated a highly sensitive and specific five-plex one-step RT-ddPCR assay for SARS-CoV-2. We first designed in-silico novel primers and probes for the simultaneous absolute quantification of three different regions of the nucleoprotein (N) gene of SARS-CoV-2 (N1, N2, N3), a synthetic RNA as an external control (RNA-EC), and Beta-2-Microglobulin (B2M) as an endogenous RNA internal control (RNA-IC). The developed assay was analytically validated using synthetic DNA and RNA calibrator standards and then was applied to 100 clinical specimens previously analyzed with a commercially available CE-IVD RT-qPCR assay. The analytical validation of the developed assay resulted in very good performance characteristics in terms of analytical sensitivity, linearity, analytical specificity, and reproducibility and recovery rates even at very low viral concentrations. The simultaneous absolute quantification of the RNA-EC and RNA-IC provides the necessary metrics for quality control assessment. Direct comparison of the developed one-step five-plex RT-ddPCR assay with a CE-IVD RT-qPCR kit revealed a very high concordance and a higher sensitivity [concordance 99/100 (99.0%, Spearman's correlation coefficient -0.850, p < 0.001)]. The developed assay is highly sensitive, specific, and reproducible and has a broad linear dynamic range, providing absolute quantification of SARS-COV-2 transcripts. The inclusion of two RNA quality controls, an external and an internal, is highly important for standardization of SARS-COV-2 molecular testing in clinical and wastewater samples.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: SARS-CoV-2 / COVID-19 Tipo de estudio: Diagnostic_studies / Guideline Idioma: En Revista: Anal Chem Año: 2022 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: SARS-CoV-2 / COVID-19 Tipo de estudio: Diagnostic_studies / Guideline Idioma: En Revista: Anal Chem Año: 2022 Tipo del documento: Article