Your browser doesn't support javascript.
loading
Hydrophilic Covalent Organic Frameworks Coated Steel Sheet As a Mass Spectrometric Ionization Source for the Direct Determination of Zearalenone and Its Derivatives.
Wang, Wenhua; Liu, Tong; Wang, Youfa; Mu, Guodong; Zhang, Feng; Yang, Qingli; Hou, Xiudan.
Afiliación
  • Wang W; Institute of Food Safety, Chinese Academy of Inspection & Quarantine, Beijing 100176, China.
  • Liu T; School of Food Science and Engineering, Qingdao Agricultural University, Qingdao, Shandong 266109, China.
  • Wang Y; Key Laboratory of Food Quality and Safety for State Market Regulation, Beijing 100176, China.
  • Mu G; Institute of Food Safety, Chinese Academy of Inspection & Quarantine, Beijing 100176, China.
  • Zhang F; Key Laboratory of Food Quality and Safety for State Market Regulation, Beijing 100176, China.
  • Yang Q; Institute of Food Safety, Chinese Academy of Inspection & Quarantine, Beijing 100176, China.
  • Hou X; Key Laboratory of Food Quality and Safety for State Market Regulation, Beijing 100176, China.
J Agric Food Chem ; 70(38): 12211-12219, 2022 Sep 28.
Article en En | MEDLINE | ID: mdl-36100997
ABSTRACT
Zearalenone has attracted worldwide attention due to its toxic properties and threat to public health. A rapid determination method for zearalenone and its derivatives by hydrophilic covalent organic frameworks coated steel sheet (HCOFCS) combined with ambient mass spectrometry (AMS) was developed. The HCOFCS behaved as both a tip for solid-phase microextraction and a solid substrate for electrospray ionization mass spectrometry (ESI-MS). To evaluate the HCOFCS-ESI-MS method, five zearalenone and its derivatives in milk samples were determined, including zearalenone (ZEA), α-zearalenol (α-ZEL), ß-zearalenol (ß-ZEL), α-zearalanol (α-ZAL), and ß-zearalanol (ß-ZAL). After the extraction procedure, the HCOFCS was directly added with a high voltage for ESI-MS, and the analysis could be completed within 1 min. The developed method showed good linearity in the range 0.1-100 µg/L with a coefficient of determination (R2) > 0.9991. The limits of detection (LODs) and limits of quantitation (LOQs) ranged from 0.05 to 0.1 and 0.2 to 0.3 µg/L, respectively. The results demonstrated that the HCOFCS combined with ESI-MS can be used for the rapid and sensitive determination of trace ZEA and its derivatives in milk samples with satisfactory recoveries from 80.58% to 109.98% and reproducibility with relative standard deviations (RSDs) no more than 11.18%. Furthermore, HCOFCS showed good reusability, which could reuse at least 10 extraction cycles with satisfactory adsorption performance.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Zearalenona / Zeranol / Estructuras Metalorgánicas Idioma: En Revista: J Agric Food Chem Año: 2022 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Zearalenona / Zeranol / Estructuras Metalorgánicas Idioma: En Revista: J Agric Food Chem Año: 2022 Tipo del documento: Article