Your browser doesn't support javascript.
loading
Diagnostic accuracy of pelvis multiparametric MRI against CT virtual hysterosalpingography: a prospective study of tubal patency through female infertility assessment.
Heuser, Guilherme Galante; Medeiros, Tássia Machado; Heuser, Henrique Galante; Scopel, Karen Rafaela Okaseski; Battisti, Iara Denise Endruweit; Hochhegger, Bruno; Winkelmann, Eliane Roseli.
Afiliación
  • Heuser GG; Hospital Unimed Noroeste, Ijuí, RS, Brazil.
  • Medeiros TM; Program in Comprehensive Health Care (UNICRUZ/UNIJUI/URI), Regional University of Northwestern Rio Grande do Sul (UNIJUI), Ijuí, RS, Brazil.
  • Heuser HG; Hospital Unimed Noroeste, Ijuí, RS, Brazil.
  • Scopel KRO; Hospital Unimed Noroeste, Ijuí, RS, Brazil.
  • Battisti IDE; Northwestern Regional University of Rio Grande do Sul State, Ijuí, RS, Brazil.
  • Hochhegger B; Master's Program in Public Policy and Development and the Master's Program in Environment and Sustainable Technologies, Federal University of the Southern Frontier de Cerro Largo, Cerro Largo, RS, Brazil.
  • Winkelmann ER; University of Florida, Gainesville, FL, USA.
Br J Radiol ; 96(1146): 20220889, 2023 Jun 01.
Article en En | MEDLINE | ID: mdl-37066809
ABSTRACT

OBJECTIVE:

To evaluate the diagnostic accuracy of MRI-hysterosalpingogram (HSG) with semiquantitative dynamic contrast-enhanced perfusion, against the virtual multislice CT hysterosalpingogram (VHSG) as a reference standard. METHODS AND MATERIALS In this prospective study, 26 women (age >18 years) searching for infertility causes and with VHSG physician request. Thereafter, the assessment performance of both techniques was determined by two reader analyses. k statistics were used for the assessment of tubal patency. Receiver operating characteristic (ROC) analysis was used to compare the capability for tubal patency assessment between both exams on a per-patient and per-tube basis. The McNemar test was used to compare the diagnostic accuracy measures.

RESULTS:

Tubal patency, uterine morphological, ovarian, and extrauterine abnormalities were evaluated through both exams in all 26 women. There was no significant difference between diagnostic performance measurements between the methods. The ROC curve of VHSG was 0.852 for both per-patient and per-tube analyses, and one and 0.938 for MRI-HSG. Sensitivity and specificity for per-patient and per-tube for VHSG were 95.2 and 97.7, 80 and 87.5%, and for MRI-HSG 100% for both analyses and 100 and 87.5%, respectively.

CONCLUSION:

This study demonstrates the feasibility of diagnosing tubal patency through MRI, using a semi-quantitative dynamic contrast-enhanced perfusion sequence, and the satisfactory diagnosing of the uterine morphology, ovarian abnormalities, and ovarian and deep endometriosis. ADVANCES IN KNOWLEDGE Multiparametric MRI with a perfusion real-time sequence as a HSG method can be used in the evaluation not only for uterine and ovarian abnormilities but also tubal patency.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Enfermedades de las Trompas Uterinas / Imágenes de Resonancia Magnética Multiparamétrica / Infertilidad Femenina Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies Idioma: En Revista: Br J Radiol Año: 2023 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Enfermedades de las Trompas Uterinas / Imágenes de Resonancia Magnética Multiparamétrica / Infertilidad Femenina Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies Idioma: En Revista: Br J Radiol Año: 2023 Tipo del documento: Article