Your browser doesn't support javascript.
loading
Method for estimating pulsatile wall shear stress from one-dimensional velocity waveforms.
Muskat, J C; Babbs, C F; Goergen, C J; Rayz, V L.
Afiliación
  • Muskat JC; Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA.
  • Babbs CF; Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA.
  • Goergen CJ; Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA.
  • Rayz VL; Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA.
Physiol Rep ; 11(7): e15628, 2023 04.
Article en En | MEDLINE | ID: mdl-37066977
ABSTRACT
Wall shear stress (WSS)-a key regulator of endothelial function-is commonly estimated in vivo using simplified mathematical models based on Poiseuille's flow, assuming a quasi-steady parabolic velocity distribution, despite evidence that more rapidly time-varying, pulsatile blood flow during each cardiac cycle modulates flow-mediated dilation (FMD) in large arteries of healthy subjects. More exact and accurate models based on the well-established Womersley solution for rapidly changing blood flow have not been adopted clinically, potentially because the Womersley solution relies on the local pressure gradient, which is difficult to measure non-invasively. We have developed an open-source method for automatic reconstruction of unsteady, Womersley-derived velocity profiles, and WSS in conduit arteries. The proposed method (available online at https//doi.org/10.5281/zenodo.7576408) requires only the time-averaged diameter of the vessel and time-varying velocity data available from non-invasive imaging such as Doppler ultrasound. Validation of the method with subject-specific computational fluid dynamics and application to synthetic velocity waveforms in the common carotid, brachial, and femoral arteries reveals that the Poiseuille solution underestimates peak WSS 38.5%-55.1% during the acceleration and deceleration phases of systole and underestimates or neglects retrograde WSS. Following evidence that oscillatory shear significantly augments vasodilator production, it is plausible that mischaracterization of the shear stimulus by assuming parabolic flow leads to systematic underestimates of important biological effects of time-varying blood velocity in conduit arteries.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Arterias Carótidas / Hemodinámica Tipo de estudio: Diagnostic_studies Idioma: En Revista: Physiol Rep Año: 2023 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Arterias Carótidas / Hemodinámica Tipo de estudio: Diagnostic_studies Idioma: En Revista: Physiol Rep Año: 2023 Tipo del documento: Article