Your browser doesn't support javascript.
loading
Evaluation of the Sysmex UF-4000i urine analyzer as a screening test to rule out urinary tract infection and reduce urine cultures. / Évaluation de l'analyseur Sysmex UF-4000i comme test de dépistage pour exclusion des infections urinaires et diminution des mises en culture
El Kettani, Assiya; Housbane, Samy; Wakit, Fatima; Mikou, Karima Arioua; Belabbes, Houria; Zerouali, Khalid.
Afiliación
  • El Kettani A; Bacteriology-Virology and Hospital Hygiene Laboratory, University Hospital Centre Ibn Rochd of Casablanca, Morocco, Department of Microbiology, Faculty of Medicine and Pharmacy, Hassan II University of Casablanca, Morocco.
  • Housbane S; Laboratory of medical informatics, Faculty of Medicine and Pharmacy, Hassan II University of Casablanca, Morocco.
  • Wakit F; Bacteriology-Virology and Hospital Hygiene Laboratory, University Hospital Centre Ibn Rochd of Casablanca, Morocco, Department of Microbiology, Faculty of Medicine and Pharmacy, Hassan II University of Casablanca, Morocco.
  • Mikou KA; Scientific Department, Megaflex SARL, Casablanca, Morocco.
  • Belabbes H; Bacteriology-Virology and Hospital Hygiene Laboratory, University Hospital Centre Ibn Rochd of Casablanca, Morocco, Department of Microbiology, Faculty of Medicine and Pharmacy, Hassan II University of Casablanca, Morocco.
  • Zerouali K; Bacteriology-Virology and Hospital Hygiene Laboratory, University Hospital Centre Ibn Rochd of Casablanca, Morocco, Department of Microbiology, Faculty of Medicine and Pharmacy, Hassan II University of Casablanca, Morocco.
Ann Biol Clin (Paris) ; 81(2): 156-161, 2023 05 16.
Article en En, Fr | MEDLINE | ID: mdl-37144792
ABSTRACT

INTRODUCTION:

Urinary tract infection (UTI) diagnosis by urine culture is time- and labor- consuming. In the Ibn Rochd microbiology laboratory, up to 70% of urine culture samples yield no growth or insignificant growth.

OBJECTIVE:

To evaluate the new generation of Sysmex UF-4000i fluorescence flow cytometry analyzer with a blue semiconducting laser as a method to rule out negative urine samples for UTI, in comparison of urine culture. MATERIAL AND

METHODS:

Flow cytometry and microbiological analysis were performed on 502 urine samples included in the study. We used ROC analysis to determine cutoff points at which optimal sensitivity and specificity are achieved for clinical use.

RESULTS:

Our results showed that bacteria count at a cut-off of 100/µL, and/or the leucocytes count ≥ 45/µL are the optimal indicator for positive culture results. At these cut off, bacteria sensitivity (SE), specificity (SP), Positive predictive value (PPV) and negative predictive value (NPV) were 97,3%, 95%, 87,8% and 98,8% respectively. For leucocytes, SE, SP, PPV and NPV were 99,1%, 95,8%, 88,6% and 99,7% respectively. DISCUSSION AND

CONCLUSION:

The bacterial and leucocytes counts generated by UF-4000i analysis may be useful in our context as a rapid screening to exclude UTI by reducing about 70% of urines cultures and then workload. Nevertheless, further validation is needed for different patient groups especially with urological disease or immunocompromised patients.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Infecciones Urinarias / Urinálisis Tipo de estudio: Diagnostic_studies / Screening_studies Idioma: En / Fr Revista: Ann Biol Clin (Paris) Año: 2023 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Infecciones Urinarias / Urinálisis Tipo de estudio: Diagnostic_studies / Screening_studies Idioma: En / Fr Revista: Ann Biol Clin (Paris) Año: 2023 Tipo del documento: Article