Your browser doesn't support javascript.
loading
Simultaneous determination of maltol and maltol glucuronide in human plasma and urine by HPLC-MS/MS: Application in clinical study in patients with iron deficiency.
Cai, Zhengwen; Guo, Haifang; Zhou, Qiaoyun; Zhao, Shunbo; Ding, Li.
Afiliación
  • Cai Z; Department of Pharmaceutical Analysis, China Pharmaceutical University, Nanjing, China.
  • Guo H; Department of Clinical Pharmacology, Jiangsu Aosaikang Pharmaceutical Co. Ltd, Nanjing, China.
  • Zhou Q; Nanjing Clinical Tech. Laboratories Inc, Nanjing, China.
  • Zhao S; Nanjing Clinical Tech. Laboratories Inc, Nanjing, China.
  • Ding L; Department of Pharmaceutical Analysis, China Pharmaceutical University, Nanjing, China; Nanjing Clinical Tech. Laboratories Inc, Nanjing, China. Electronic address: dingli@cpu.edu.cn.
Article en En | MEDLINE | ID: mdl-37270862
ABSTRACT
Ferric maltol has been used as an oral drug for iron deficiency. This study developed and fully validated the novel HPLC-MS/MS methods to determine maltol and maltol glucuronide simultaneously in plasma and urine. The protein precipitation was performed by addition of acetonitrile in the plasma samples. The dilution was performed for the urine samples to reach the suitable concentrations for injection. The multiple reaction monitoring (MRM) with an electrospray ionization (ESI) positive ion detection mode was used for the quantification. The maltol concentration linear ranges were 6.00-150 ng/mL and 0.100-10.0 µg/mL for the plasma and urine samples, respectively. The maltol glucuronide concentration linear ranges were 50.0-15000 ng/mL and 2.00-2000 µg/mL for the plasma and urine samples, respectively. These methods were applied to a single dose clinical study at a dose of 60 mg ferric maltol capsule in the patients with iron deficiency. The half-lives of maltol and maltol glucuronide were 0.90 ± 0.40 h and 1.02 ± 0.25 h in the iron deficiency patients, respectively. 39.52 ± 7.11 % maltol were excreted in urine in the form of maltol glucuronide.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Espectrometría de Masas en Tándem / Deficiencias de Hierro Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2023 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Espectrometría de Masas en Tándem / Deficiencias de Hierro Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2023 Tipo del documento: Article