Your browser doesn't support javascript.
loading
Solvent-free automated thermal desorption-gas chromatography/mass spectrometry for direct screening of hazardous compounds in consumer textiles.
Carlsson, Josefine; Åström, Tim; Östman, Conny; Nilsson, Ulrika.
Afiliación
  • Carlsson J; Department of Materials and Environmental Chemistry, Stockholm University, SE-106 91, Stockholm, Sweden.
  • Åström T; Department of Materials and Environmental Chemistry, Stockholm University, SE-106 91, Stockholm, Sweden.
  • Östman C; Department of Materials and Environmental Chemistry, Stockholm University, SE-106 91, Stockholm, Sweden.
  • Nilsson U; Department of Materials and Environmental Chemistry, Stockholm University, SE-106 91, Stockholm, Sweden. ulrika.nilsson@mmk.su.se.
Anal Bioanal Chem ; 415(19): 4675-4687, 2023 Aug.
Article en En | MEDLINE | ID: mdl-37338566
ABSTRACT
The global production of textiles utilizes numerous large-volume chemicals that may remain to some extent in the finished garments. Arylamines, quinolines, and halogenated nitrobenzene compounds are possible mutagens, carcinogens and/or skin sensitizers. For prevention, control of clothing and other textiles must be improved, especially those imported from countries without regulations of textile chemicals. An automated analytical methodology with on-line extraction, separation, and detection would largely simplify screening surveys of hazardous chemicals in textiles. Automated thermal desorption-gas chromatography/mass spectrometry (ATD-GC/MS) was developed and evaluated as a solvent-free, direct chemical analysis for screening of textiles. It requires a minimum of sample handling with a total run time of 38 min including sample desorption, chromatographic separation, and mass spectrometric detection. For most of the studied compounds, method quantification limit (MQL) was below 5 µg/g for 5 mg of textile sample, which is sufficiently low for screening and control of quinoline and arylamines regulated by EU. Several chemicals were detected and quantified when the ATD-GC/MS method was applied in a limited pilot screening of synthetic fiber garments. A number of arylamines were detected, where some of the halogenated dinitroanilines were found in concentrations up to 300 µg/g. This is ten times higher than the concentration limit for similar arylamines listed by the EU REACH regulation. Other chemicals detected in the investigated textiles were several quinolines, benzothiazole, naphthalene, and 3,5-dinitrobromobenzene. Based on the present results, we suggest ATD-GC/MS as a screening method for the control of harmful chemicals in clothing garments and other textiles.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Quinolinas / Textiles Tipo de estudio: Diagnostic_studies / Risk_factors_studies / Screening_studies Idioma: En Revista: Anal Bioanal Chem Año: 2023 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Quinolinas / Textiles Tipo de estudio: Diagnostic_studies / Risk_factors_studies / Screening_studies Idioma: En Revista: Anal Bioanal Chem Año: 2023 Tipo del documento: Article