Your browser doesn't support javascript.
loading
Sensitive detection of 17ß-estradiol at a picomolar level using an aptamer-assisted liquid crystal-based optical sensor.
Ahn, Jun-Seong; Jang, Chang-Hyun.
Afiliación
  • Ahn JS; Department of Chemistry, Gachon University, Seongnam-daero 1342, Sujeong-Gu, Seongnam-Si, Gyeonggi-Do, 13120, Republic of Korea.
  • Jang CH; Department of Chemistry, Gachon University, Seongnam-daero 1342, Sujeong-Gu, Seongnam-Si, Gyeonggi-Do, 13120, Republic of Korea. chjang4u@gachon.ac.kr.
Anal Bioanal Chem ; 415(25): 6323-6332, 2023 Oct.
Article en En | MEDLINE | ID: mdl-37581706
A liquid crystal (LC)-based aptasensor was developed that can detect 17ß-estradiol (E2) at the picomolar level. This aptasensor is based on competitive reactions of the aptamer that interacts with cetyl trimethyl ammonium bromide (CTAB) and E2 at the aqueous/LC interface. The long alkyl chain of CTAB anchored the 4-cyano-4'-pentylbiphenyl (5CB) to a homeotropic state and controls the local anchoring depending on the extent of electrostatic interaction with the aptamer. Upon addition of the aptamer solution to the CTAB-saturated LC layer, LCs change from dark to bright optical response. This is due to the perturbed orientation of 5CB at the aqueous/LC interface as a result of electrostatic attraction of the cationic group of CTAB and the phosphate group of the aptamer. The conformational change of the aptamer due to specific binding with E2 weakens the electrostatic attraction between CTAB and aptamer. When specific binding becomes relatively dominant, CTAB induces the orientation of LCs to the homeotropic state, resulting in a dark optical image observed. We also analyzed the change in the optical response of LCs according to the interfacial events and compared the grayscale values of the optical image for each concentration of E2 to determine the detection limit. Accordingly, the detection limit of the E2 sensor was found to be 3.1 pM (0.8 pg/ml) in Tris-buffered saline (TBS), and 6.8 pM (1.9 pg/ml) in human urine. The LC-based optical aptasensor was thus shown to be highly sensitive and selective with no requirement for complex analysis equipment.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Bioanal Chem Año: 2023 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Bioanal Chem Año: 2023 Tipo del documento: Article