Your browser doesn't support javascript.
loading
High throughput, spatially resolved thermal properties measurement using attachable and reusable 3ω sensors.
Chalise, Divya; Tee, Richard; Zeng, Yuqiang; Kaur, Sumanjeet; Pokharna, Himanshu; Prasher, Ravi S.
Afiliación
  • Chalise D; Department of Mechanical Engineering, University of California, Berkeley, California 94720, USA.
  • Tee R; Energy Technologies Area, Lawrence Berkeley National Lab, 1 Cyclotron Road, Berkeley, California 94720, USA.
  • Zeng Y; Department of Mechanical Engineering, University of California, Berkeley, California 94720, USA.
  • Kaur S; Energy Technologies Area, Lawrence Berkeley National Lab, 1 Cyclotron Road, Berkeley, California 94720, USA.
  • Pokharna H; Energy Technologies Area, Lawrence Berkeley National Lab, 1 Cyclotron Road, Berkeley, California 94720, USA.
  • Prasher RS; Energy Technologies Area, Lawrence Berkeley National Lab, 1 Cyclotron Road, Berkeley, California 94720, USA.
Rev Sci Instrum ; 94(9)2023 Sep 01.
Article en En | MEDLINE | ID: mdl-37676087
ABSTRACT
The 3ω method is a well-established thermal technique used to measure the thermal conductivity of materials and the thermal resistance of interfaces. It has significant advantages over other steady state and transient thermal techniques in its ability to provide spatially resolved thermal property measurements over a wide range of thermal conductivity. Despite its advantages, it has been restricted to lab-scale use because of the difficulty involved in sample preparation and sensor fabrication and is limited to non-metallic substrates. High-throughput 3ω measurements with reusable sensors have not been realized yet. In this work, we demonstrate a method of applying reusable 3ω sensors fabricated on flexible polyimide films to measure bulk and spatially resolved thermal properties. We establish the limits of thermal conductivity measurement with the method to be 1 to 200 W/mK, and within the measurement limit, we verify the method by comparing the measured thermal conductivities of standard samples with established values. From the 3ω measurements, we also determine the thermal resistance of an interlayer of thermal grease as a function of pressure and compare it against the resistance calculated from direct thickness measurements to demonstrate the ability of this method to provide spatially resolved subsurface information. The technique presented is general and applicable to both metallic and non-metallic substrates, providing a method for high-throughput 3ω measurements with reusable sensors and without considerable sample preparation.

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2023 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2023 Tipo del documento: Article