Your browser doesn't support javascript.
loading
A Chitosan-Based Fluorescent Probe Combined with Smartphone Technology for the Detection of Hypochlorite in Pure Water.
Yuan, Xushuo; Zhang, Wenli; Liu, Li; Lin, Yanfei; Xie, Linkun; Chai, Xijuan; Xu, Kaimeng; Du, Guanben; Zhang, Lianpeng.
Afiliación
  • Yuan X; Yunnan Provincial Key Laboratory of Wood Adhesives and Glued Products, Southwest Forestry University, Kunming 650224, China.
  • Zhang W; Yunnan Provincial Key Laboratory of Wood Adhesives and Glued Products, Southwest Forestry University, Kunming 650224, China.
  • Liu L; Yunnan Provincial Key Laboratory of Wood Adhesives and Glued Products, Southwest Forestry University, Kunming 650224, China.
  • Lin Y; College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, China.
  • Xie L; Yunnan Provincial Key Laboratory of Wood Adhesives and Glued Products, Southwest Forestry University, Kunming 650224, China.
  • Chai X; Yunnan Provincial Key Laboratory of Wood Adhesives and Glued Products, Southwest Forestry University, Kunming 650224, China.
  • Xu K; Yunnan Provincial Key Laboratory of Wood Adhesives and Glued Products, Southwest Forestry University, Kunming 650224, China.
  • Du G; Yunnan Provincial Key Laboratory of Wood Adhesives and Glued Products, Southwest Forestry University, Kunming 650224, China.
  • Zhang L; Yunnan Provincial Key Laboratory of Wood Adhesives and Glued Products, Southwest Forestry University, Kunming 650224, China.
Molecules ; 28(17)2023 Aug 29.
Article en En | MEDLINE | ID: mdl-37687144
ABSTRACT
Using chitosan as a raw material, 1,8-naphthimide as the fluorescent chromophore, and sulfur-containing compounds as the recognition groups, a novel naphthimide-functionalized chitosan probe, CS-BNS, for the detection of ClO- was successfully synthesized. The modification of chitosan was verified by SEM, XRD, FTIR, mapping, 13C-NMR, TG and the structure of the probe molecule was characterized. The identification performance of the probes was studied using UV and fluorescence spectrophotometers. The results show that CS-BNS exhibits a specific response to ClO- based on the oxidative reaction of ClO- to the recognition motifs, as well as a good resistance to interference. And the probe has high sensitivity and fast response time, and can complete the detection of ClO- in a pure water system within 60 s. The probe can also quantify ClO- (y = 30.698x + 532.37, R2 = 0.9833) with a detection limit as low as 0.27 µM. In addition, the combination of the probe with smartphone technology enables the visualization and real-time monitoring of ClO-. Moreover, an identification system for ClO- was established by combining the probe with smartphone technology, which realized the visualization and real-time monitoring of ClO-.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Molecules Asunto de la revista: BIOLOGIA Año: 2023 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Molecules Asunto de la revista: BIOLOGIA Año: 2023 Tipo del documento: Article