Your browser doesn't support javascript.
loading
Four-flanged polypropylene optic piercing technique for scleral fixation of multifocal intraocular lens.
Eom, Youngsub; Koh, Eunheh; Yang, Seul Ki; Kim, Soo; Yi, Sungtae; Jeon, Hyun Sun; Kim, Seong-Jae; So, Jason; Song, Jong Suk; Cooke, David L.
Afiliación
  • Eom Y; Department of Ophthalmology, Korea University Ansan Hospital, Gyeonggi-do, Republic of Korea. hippotate@hanmail.net.
  • Koh E; Department of Ophthalmology, Korea University College of Medicine, Seoul, Republic of Korea. hippotate@hanmail.net.
  • Yang SK; Department of Ophthalmology, Emory University School of Medicine, Atlanta, GA, USA. hippotate@hanmail.net.
  • Kim S; Medical College of Georgia, Augusta University, Augusta, GA, USA.
  • Yi S; Space Optics Laboratory, Department of Astronomy, Yonsei University, Seoul, Republic of Korea.
  • Jeon HS; Satellite system 2 Team, Hanwha Systems Co., Ltd, Gyeonggi-do, Republic of Korea.
  • Kim SJ; BNeye Clinic, Seoul, Republic of Korea.
  • So J; BNeye Clinic, Seoul, Republic of Korea.
  • Song JS; Department of Ophthalmology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.
  • Cooke DL; Department of Ophthalmology, Gyeongsang National University Hospital, Gyeongsang National University College of Medicine, Jinju, Republic of Korea.
BMC Ophthalmol ; 23(1): 392, 2023 Sep 26.
Article en En | MEDLINE | ID: mdl-37752479
BACKGROUND: To evaluate the feasibility of creating flanges using an optic piercing technique with a 6 - 0 polypropylene monofilament for scleral fixation of dislocated one-piece diffractive multifocal intraocular lenses (IOLs). STUDY DESIGN: Experimental study and case series. SUBJECTS: Optical bench test and eyes with IOL dislocation. METHODS: Two separate 6 - 0 polypropylenes were penetrated twice at the opposite peripheral optic of the TECNIS Synergy IOL (Johnson & Johnson Vision). The root mean square of the modulation transfer function (MTFRMS), at between + 1.00 and - 4.00 D of defocus, was measured in the TECNIS Synergy IOL both with and without optic piercing in the optical bench study. This case series included three eyes from two patients who underwent scleral-fixation of multifocal IOLs using the four-flanged polypropylene optic piercing technique. The postoperative corrected distance visual acuity (CDVA) at 4 m, the uncorrected near visual acuity (UNVA) at 40 cm, and IOL centration were evaluated. RESULTS: The optical bench test showed no differences in MTFRMS values measured in the TECNIS Synergy IOL, either with or without optic piercing at all defocuses. In all three case series, the postoperative CDVA at 4 m was 20/20 and UNVA at 40 cm was J1. Postoperative anterior segment photographs showed good centration of IOLs in all cases. CONCLUSION: The four-flanged polypropylene optic piercing technique for multifocal IOL scleral fixation can provide excellent clinical outcomes and IOL stability after surgery without diminishing the performance of the multifocal IOLs.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Lentes Intraoculares Multifocales / Lentes Intraoculares Idioma: En Revista: BMC Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2023 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Lentes Intraoculares Multifocales / Lentes Intraoculares Idioma: En Revista: BMC Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2023 Tipo del documento: Article