Your browser doesn't support javascript.
loading
Comparison between Novel Anatomical Locking Guide Plate and Conventional Locking Plate for Acetabular Fractures: A Finite Element Analysis.
Liu, Xiao; Gao, Jianpeng; Wu, Xiaoyong; Deng, Junhao; Li, Zijian; Li, Ran; Zhang, Licheng; Liu, Jianheng; Li, Ming.
Afiliación
  • Liu X; Department of Orthopaedics, The First Medical Center of the Chinese PLA General Hospital, No. 28 Fuxin Road, Beijing 100853, China.
  • Gao J; National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, No. 28 Fuxin Road, Beijing 100853, China.
  • Wu X; Department of Orthopaedics, The First Medical Center of the Chinese PLA General Hospital, No. 28 Fuxin Road, Beijing 100853, China.
  • Deng J; National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, No. 28 Fuxin Road, Beijing 100853, China.
  • Li Z; Department of Orthopaedics, The First Medical Center of the Chinese PLA General Hospital, No. 28 Fuxin Road, Beijing 100853, China.
  • Li R; National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, No. 28 Fuxin Road, Beijing 100853, China.
  • Zhang L; Department of Orthopaedics, The First Medical Center of the Chinese PLA General Hospital, No. 28 Fuxin Road, Beijing 100853, China.
  • Liu J; National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, No. 28 Fuxin Road, Beijing 100853, China.
  • Li M; Department of Orthopaedics, The First Medical Center of the Chinese PLA General Hospital, No. 28 Fuxin Road, Beijing 100853, China.
Life (Basel) ; 13(11)2023 Oct 24.
Article en En | MEDLINE | ID: mdl-38004248
ABSTRACT
The treatment of complex acetabular fractures remains a complicated clinical challenge. Our self-designed novel anatomical locking guide plate (NALGP) has previously shown promising potential in T-shaped acetabular fractures (TAF), but a direct comparison with conventional fixations is yet to be made. The TAF model was established based on a volunteer's computer tomography data and then fixed with double column locking plates (DLP), a posterior column locking plate with anterior column screws (LPACS), and our NALGP. Forces of 200 N, 400 N, and 600 N were then loaded on the model vertically downward, respectively. The stress distribution and peaks and maximum displacements at three sites were assessed. We found that the stress area of all three plates was mainly concentrated around the fracture line, while only the matching screws of the NALGP showed no obvious stress concentration points. In addition, the NALGP and DLP showed significantly less fracture fragment displacement than the LPACS at the three main fracture sites. The NALGP was found to have less displacement than DLP at the posterior column and ischiopubic branch sites, especially under the higher loading forces of 400 N and 600 N. The fixation stability of the NALGP for TAF was similar to that of DLP but better than that of LPACS. Moreover, the NALGP and its matching screws have a more reasonable stress distribution under different loads of force and the same strength as the LPACS.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Life (Basel) Año: 2023 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Life (Basel) Año: 2023 Tipo del documento: Article