Validation of the Textural Realism of a 3D Anthropomorphic Phantom for Digital Breast Tomosynthesis.
Acciavatti, Raymond J; Hsieh, Meng-Kang; Gastounioti, Aimilia; Hu, Yifan; Chen, Jinbo; Maidment, Andrew D A; Kontos, Despina.
Afiliación
  • Acciavatti RJ; University of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia PA 19104.
  • Hsieh MK; University of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia PA 19104.
  • Gastounioti A; University of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia PA 19104.
  • Hu Y; University of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia PA 19104.
  • Chen J; University of Pennsylvania, Department of Epidemiology, Biostatistics, & Informatics, 423 Guardian Drive, Philadelphia PA 19104.
  • Maidment ADA; University of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia PA 19104.
  • Kontos D; University of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia PA 19104.
Article en En | MEDLINE | ID: mdl-38222313
ABSTRACT
In this paper, texture calculations are used to validate the realism of a physical anthropomorphic phantom for digital breast tomosynthesis. The texture features were compared against clinical mammography data. Three groups of features (grey-level histogram, co-occurrence, and run-length) were considered. The features were analyzed over a broad range of technique settings (kV and mAs). These calculations were done in the central slice of the reconstruction as well as the synthetic 2D mammogram. For each feature, the clinical data were binned into strata based on the compressed breast thickness. It was demonstrated that the clinical features vary by thickness. To evaluate the realism of the phantom, each feature was compared against clinical data in the same thickness stratum. For the purpose of this paper, a feature was considered to be realistic if it was within the middle 95% of the statistical distribution of clinical values. In the reconstruction, most features were found to exhibit realism; specifically, all 12 grey-level histogram features, four out of seven co-occurrence features, and three out of seven run-length features. The realism of most features was robust to changes in the technique settings. However, in the synthetic 2D mammogram, fewer features were found to exhibit realism. In conclusion, this paper provides a validation of the textural realism of the phantom in the reconstruction, and shows that there is less realism in the synthetic 2D mammogram. We identify the features that should be considered to refine the design of the phantom in future work.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Proc SPIE Int Soc Opt Eng Año: 2018 Tipo del documento: Article