Your browser doesn't support javascript.
loading
Touchless Thermosensation Enabled by Flexible Infrared Photothermoelectric Detector for Temperature Prewarning Function of Electronic Skin.
Guo, Xiaohan; Lu, Xiaowei; Jiang, Peng; Bao, Xinhe.
Afiliación
  • Guo X; State Key Laboratory of Catalysis, CAS Center for Excellence in Nanoscience, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, China.
  • Lu X; University of Chinese Academy of Sciences, Beijing, 100049, China.
  • Jiang P; State Key Laboratory of Catalysis, CAS Center for Excellence in Nanoscience, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, China.
  • Bao X; School of Biomedical Engineering, Suzhou Institute for Advanced Research, University of Science and Technology of China, Suzhou, 215123, China.
Adv Mater ; 36(23): e2313911, 2024 Jun.
Article en En | MEDLINE | ID: mdl-38424290
ABSTRACT
Artificial skin, endowed with the capability to perceive thermal stimuli without physical contact, will bring innovative interactive experiences into smart robotics and augmented reality. The implementation of touchless thermosensation, responding to both hot and cold stimuli, relies on the construction of a flexible infrared detector operating in the long-wavelength infrared range to capture the spontaneous thermal radiation. This imposes rigorous requirements on the photodetection performance and mechanical flexibility of the detector. Herein, a flexible and wearable infrared detector is presented, on basis of the photothermoelectric coupling of the tellurium-based thermoelectric multilayer film and the infrared-absorbing polyimide substrate. By suppressing the optical reflection loss and aligning the destructive interference position with the absorption peak of polyimide, the fabricated thermopile detector exhibits high sensitivity to the thermal radiation over a broad source temperature range from -50 to 110 °C, even capable of resolving 0.05 °C temperature change. Spatially resolved radiation distribution sensing is also achieved by constructing an integrated thermopile array. Furthermore, an established temperature prewarning system is demonstrated for soft robotic gripper, enabling the identification of noxious thermal stimuli in a contactless manner. A feasible strategy is offered here to integrate the infrared detection technique into the sensory modality of electronic skin.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Dispositivos Electrónicos Vestibles / Rayos Infrarrojos Idioma: En Revista: Adv Mater Asunto de la revista: BIOFISICA / QUIMICA Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Dispositivos Electrónicos Vestibles / Rayos Infrarrojos Idioma: En Revista: Adv Mater Asunto de la revista: BIOFISICA / QUIMICA Año: 2024 Tipo del documento: Article