Your browser doesn't support javascript.
loading
The cathodically pretreated boron-doped diamond electrode as an environmentally friendly electrochemical tool for the detection and monitoring of mesotrione in food samples.
Mijajlovic, Aleksandar; Stankovic, Vesna; Vlahovic, Filip; Durdic, Sladana; Manojlovic, Dragan; Stankovic, Dalibor.
Afiliación
  • Mijajlovic A; Faculty of Chemistry, University of Belgrade, Studentski trg 12-16, 11000 Belgrade, Serbia.
  • Stankovic V; Institute of Chemistry, Technology and Metallurgy - National Institute of the Republic of Serbia, University of Belgrade, Njegoseva 12, 11000 Belgrade, Serbia. Electronic address: vesna.stankovic@ihtm.bg.ac.rs.
  • Vlahovic F; Institute of Chemistry, Technology and Metallurgy - National Institute of the Republic of Serbia, University of Belgrade, Njegoseva 12, 11000 Belgrade, Serbia.
  • Durdic S; Faculty of Chemistry, University of Belgrade, Studentski trg 12-16, 11000 Belgrade, Serbia.
  • Manojlovic D; Faculty of Chemistry, University of Belgrade, Studentski trg 12-16, 11000 Belgrade, Serbia.
  • Stankovic D; Faculty of Chemistry, University of Belgrade, Studentski trg 12-16, 11000 Belgrade, Serbia; Vinca Institute of Nuclear Sciences - National Institute of the Republic of Serbia, University of Belgrade, 11000 Belgrade, Serbia.
Food Chem ; 447: 138993, 2024 Jul 30.
Article en En | MEDLINE | ID: mdl-38493684
ABSTRACT
Excessive pesticide use can harm human health, making it essential to develop new techniques to monitor hazardous pesticides in food. Our study focuses on detecting mesotrione (MST) using an unmodified boron-doped diamond (BDD) electrode. This was the first application of cathodically pretreated BDD electrode for the detection of MST, based on its oxidation at a high potential value of +1.4 V. We theoretically examined the oxidation mechanism of MST trough the utilization of density functional theory (DFT) methodology. The utilized DPV method achieved a detection limit of 0.45 µM and showed satisfactory selectivity. The practical application of this method was demonstrated by examining corn-based food products. To ensure practical application of the method, MST was deliberately added to the samples to evaluate the accuracy of the proposed method. The effectiveness of the method was confirmed by using HPLC method. This environmentally-friendly approach can establish a solid foundation for future use in food analysis.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Boro / Ciclohexanonas Idioma: En Revista: Food Chem Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Boro / Ciclohexanonas Idioma: En Revista: Food Chem Año: 2024 Tipo del documento: Article