Your browser doesn't support javascript.
loading
Mitigation of bio-corrosion characteristics of coronary artery stent by optimising fs-laser micromachining parameters.
Chenrayan, Venkatesh; Palanisamy, Dhanabal; Mani, Kalayarasan; Shahapurkar, Kiran; Elahi M Soudagar, Manzoore; Fouad, Yasser; Kalam, M A; Ali, Muhammad Mahmood; Nasir Bashir, Muhammad.
Afiliación
  • Chenrayan V; Polymer Composite Processing and Research Laboratory, Department of Mechanical Engineering, Alliance University, Anekal, Bengaluru, India.
  • Palanisamy D; Department of Mechanical Engineering, Yonsei University, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
  • Mani K; Department of Mechanical Engineering, PSG College of Technology, Coimbatore, India.
  • Shahapurkar K; Department of Mechanical Engineering, PSG College of Technology, Coimbatore, India.
  • Elahi M Soudagar M; School of Mechanical, Chemical and Material Engineering, Adama Science and Technology University, Adama, Ethiopia.
  • Fouad Y; Institute of Power Engineering, Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, 43000 Kajang, Selangor, Malaysia.
  • Kalam MA; Division of Research and Development, Lovely Professional University, Phagwara, Punjab, 144411, India.
  • Ali MM; Faculty of Mechanical Engineering, Opole University of Technology, 45-758, Opole, Poland.
  • Nasir Bashir M; Department of Mechanical Engineering, Graphic Era (Deemed to be University), Dehradun, Uttarakhand 248002, India.
Heliyon ; 10(6): e28057, 2024 Mar 30.
Article en En | MEDLINE | ID: mdl-38545133
ABSTRACT
Cardiovascular diseases, particularly coronary artery disease, pose big challenges to human life. Deployment of the stent is a preferable treatment for the above-mentioned disease. However, stents are usually made up of shape memory alloy called Nitinol. The poorer surface finish on the machined nitinol stents accelerates the migration of Nickel ions from the implanted nitinol stent, which is considered toxic and can lead to stenosis. The current study deals with controlling surface quality by minimising surface roughness and improving corrosion resistance. Femtosecond laser (fs-laser 10-15 s) micromachining was employed to machine the Nitinol surface to achieve sub-micron surface roughness. The Grey relational analysis (GRA)-coupled design of the experimental technique was implemented to determine optimal levels of four micromachining parameters (laser power, pulse frequency, scanning speed, and scanning pattern) varied at three levels to achieve minimum surface roughness and to maximise the volume ablation. The results show that to yield minimum surface roughness and maximum volume ablation, laser power and scanning speed are in a higher range. In contrast, the pulse frequency is lower, and the scanning pattern is in a zig-zag manner. ANOVA results manifest that scanning speed is the predominant factor in minimising surface roughness, followed by pulse frequency. Furthermore, the corrosion behaviour of the machined nitinol specimens was evaluated, and the results show that specimens with lower surface roughness had lower corrosion rates.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Heliyon Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Heliyon Año: 2024 Tipo del documento: Article