Your browser doesn't support javascript.
loading
Does the proximal humeral bone quality influence alignment after reverse total shoulder arthroplasty with short humeral stems?
Lee, Ho-Jae; Kim, Byung-Kook; Dan, Jinmyoung.
Afiliación
  • Lee HJ; Department of Orthopaedic Surgery, Gumi CHA Medical Center, CHA University School of Medicine, Sinsi-ro 10gil 12, Kyungsangbuk-do, Gumi-Si, 39314, Republic of Korea.
  • Kim BK; Department of Orthopaedic Surgery, Gumi CHA Medical Center, CHA University School of Medicine, Sinsi-ro 10gil 12, Kyungsangbuk-do, Gumi-Si, 39314, Republic of Korea.
  • Dan J; Department of Orthopaedic Surgery, Gumi CHA Medical Center, CHA University School of Medicine, Sinsi-ro 10gil 12, Kyungsangbuk-do, Gumi-Si, 39314, Republic of Korea. osjmdan@gmail.com.
Eur J Orthop Surg Traumatol ; 34(4): 2137-2145, 2024 May.
Article en En | MEDLINE | ID: mdl-38557891
ABSTRACT

PURPOSE:

When compared to standard-length humeral stem in reverse total shoulder arthroplasty (RTSA), short humeral stems in RTSA require good proximal humeral metaphyseal bone quality to gain proper and secure fixation during prosthetic implantation. Shorter humeral stems potentially carry more risk of misalignment than standard or long humeral stems. The hypothesis was that misalignment of the short humeral stems is influenced by regional bone quality.

METHODS:

RTSA with a short curved humeral stem with neck-shaft angle (NSA) default of 132.5° was reviewed. The study group included 35 cases at a mean age of 75.97 (± 6.23) years. Deltoid-tuberosity index (DTI) was measured to evaluate proximal humeral bone quality. The deltoid tuberosity index was measured at immediately above position of the upper end of the deltoid tuberosity. Stem alignment was given by the angle measured in degrees between the intramedullary humeral shaft axis and the axis of the humeral implant stem.

RESULTS:

The patient's mean DTI was 1.37 ± 0.16 (median, 1.32; range, 1.12-1.80). 22 patients had poor bone quality (DTI < 1.4), compared to 13 patients with acceptable bone quality (DTI > 1.4). After RTSA, ten humeral components (29%) were neutrally aligned, whereas 25 humeral components (71%) were misaligned. There was no correlation between misalignment and DTI (r = 0.117; p = 0.504). But there was a strong correlation between misalignment and the patient's own NSA (r = - 0.47; p = 0.004). The postoperative stem position and stem misalignment are not associated with functional outcomes (p > 0.05).

CONCLUSION:

The misalignment of the short curved humeral stem frequently occurs. Poor reginal humeral bone quality does not influence misalignment after RTSA with a short humeral stem. Postoperative stem alignment is associated with the patient's preoperative NSA and method of neck cut. The misalignment does not affect functional outcomes for midterm follow-up. Further long-term follow-up studies are needed to confirm its clinical relevance.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Diseño de Prótesis / Artroplastía de Reemplazo de Hombro / Prótesis de Hombro / Húmero Idioma: En Revista: Eur J Orthop Surg Traumatol Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Diseño de Prótesis / Artroplastía de Reemplazo de Hombro / Prótesis de Hombro / Húmero Idioma: En Revista: Eur J Orthop Surg Traumatol Año: 2024 Tipo del documento: Article