Mid-term outcomes of right ventricular papillary muscle approximation for severe functional tricuspid regurgitation.
Ito, Chihiro; Kohno, Hiroki; Matsuura, Kaoru; Watanabe, Michiko; Inui, Tomohiko; Matsumiya, Goro.
Afiliación
  • Ito C; Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine, Chiba, Japan.
  • Kohno H; Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine, Chiba, Japan.
  • Matsuura K; Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine, Chiba, Japan.
  • Watanabe M; Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine, Chiba, Japan.
  • Inui T; Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine, Chiba, Japan.
  • Matsumiya G; Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine, Chiba, Japan.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article en En | MEDLINE | ID: mdl-38603618
ABSTRACT

OBJECTIVES:

Recurrence of tricuspid regurgitation (TR) after tricuspid annuloplasty can occur in cases where a dilated right ventricle exists and subsequent leaflet tethering follows. We previously reported a new technique of the right ventricular papillary muscle approximation (RV-PMA) for functional TR associated with leaflet tethering. The objective of this study is to elucidate the mid-term outcomes and evaluate the durability of RV-PMA.

METHODS:

Between January 2014 and March 2023, we applied RV-PMA in 20 patients of advanced functional TR with severe leaflet tethering. The indication of the technique was severe TR with leaflet tethering height >8 mm, and/or a right ventricular end-diastolic diameter >45 mm. The patients were followed up with echocardiography before discharge and at annual interval thereafter.

RESULTS:

There was no perioperative mortality. In the echocardiography performed before discharge, TR was decreased to mild or less in 85%, and a significant improvement in right ventricular end-diastolic diameter and tethering height were achieved (53-45 mm and 11.1-4.4 mm, respectively). Furthermore, during the median 3-year follow-up period, TR was kept controlled mild or less in 80% of the cases.

CONCLUSIONS:

RV-PMA is considered to be a safe, effective and durable technique as an additional approach for tricuspid annuloplasty.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Músculos Papilares / Insuficiencia de la Válvula Tricúspide / Ventrículos Cardíacos Idioma: En Revista: Eur J Cardiothorac Surg / Eur. j. cardiothorac. surg / European journal of cardio-thoracic surgery Asunto de la revista: CARDIOLOGIA Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Músculos Papilares / Insuficiencia de la Válvula Tricúspide / Ventrículos Cardíacos Idioma: En Revista: Eur J Cardiothorac Surg / Eur. j. cardiothorac. surg / European journal of cardio-thoracic surgery Asunto de la revista: CARDIOLOGIA Año: 2024 Tipo del documento: Article