Your browser doesn't support javascript.
loading
Locking plate fixation in comminuted coronoid fractures with partial loss of the articular cartilage - Of basal-1 type according to the O'Driscoll classification.
Cha, Soo Min; Lee, Sang Hyun; Ga, In Ho; Kim, Yong Hwan.
Afiliación
  • Cha SM; Department of Orthopedic Surgery, Regional Rheumatoid and Degenerative Arthritis Center, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon, Korea. Electronic address: smcha@cnu.ac.kr.
  • Lee SH; Department of Orthopedic Surgery, Medical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Korea.
  • Ga IH; Department of Orthopedic Surgery, Regional Rheumatoid and Degenerative Arthritis Center, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon, Korea.
  • Kim YH; Department of Orthopedic Surgery, Regional Rheumatoid and Degenerative Arthritis Center, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon, Korea.
Injury ; 55(6): 111550, 2024 Jun.
Article en En | MEDLINE | ID: mdl-38621350
ABSTRACT

BACKGROUND:

We have attempted to restore the arc of motion by considering trochlear-coronoid articulation as a complete circle during fixation of the coronoid, even for comminuted coronoid fractures with partial loss of articular cartilage (CCFPLAC), using various kinds of locking plates. Herein, we report the radiological and clinical outcomes after fixation of the basal-1 type of CCFPLAC (O'Driscoll classification) using our method.

METHODS:

Thirty-one patients diagnosed with CCFPLAC were admitted between January 2012 and December 2020. Sixteen of these patients met the inclusion/exclusion criteria and were enrolled in this study. Surgically, the lost area (defect of articular cartilage) was never compressed or minimized, but the original height and shape of the coronoid were preserved as is. Provisionally, a few K-wires were used to maintain the original shape and position of the CCFPLAC, and various kinds of locking plates/screws were used to fix the fragment anatomically and firmly. If needed, the plate was bent to ensure stable compression of the coronoid according to its size. In a few cases, locking plates were adjusted by cutting extra screw holes.

RESULTS:

Among the 16 patients, the mean age was 46.2 years, and the malefemale ratio was 106. The mean follow-up period was 3.63 years. 8, 6, and 2 patients were designated as group 1 (isolated CCFPLAC), 2 [CCFPLAC in type 4 (terrible triad) injury), and 3 (CCFPLAC in type 5 posterior olecranon fracture-dislocations), respectively. Complete union was achieved after a mean of 8.94 weeks. The mean flexion-extension and pronation-supination arcs were 127.19 ± 4.46° and 135.31.59 ± 8.06°, respectively, which were significantly different from those on the contralateral (normal) side (p < 0.001); however, the arcs were within the functional ranges for ordinary daily living. Additionally, the functional status was satisfactory in all patients. However, Mayo Elbow Performance Score and the degree of arthritis were statistically poor in group 2.

CONCLUSIONS:

CCFPLAC of the basal-1 type (O'Driscoll classification) can be treated satisfactorily if already designed and widely distributed locking plates are properly manipulated to maintain the original geometry of the coronoid according to the individual joint characteristics. LEVEL OF EVIDENCE Level IV, Retrospective case series.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Placas Óseas / Cartílago Articular / Fracturas Conminutas / Fijación Interna de Fracturas Idioma: En Revista: Injury Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Placas Óseas / Cartílago Articular / Fracturas Conminutas / Fijación Interna de Fracturas Idioma: En Revista: Injury Año: 2024 Tipo del documento: Article