Your browser doesn't support javascript.
loading
Ultrasensitive Ti3C2Tx@Pt-Based Immunochromatography with Catalytic Amplification and a Dual Signal for the Detection of Chloramphenicol in Animal-Derived Foods.
Lin, Mengfang; Gao, Zhimin; Qian, Zhenjie; Deng, Youwen; Chen, Yanhong; Wang, Yu; Li, Xiangmei.
Afiliación
  • Lin M; Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China.
  • Gao Z; Guangdong Agricultural Product Quality and Safety Center (Guangdong Green Food Development Center), Guangzhou 510230, China.
  • Qian Z; Guangzhou Institute for Food Inspection, Guangzhou 511410, China.
  • Deng Y; Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China.
  • Chen Y; Guangzhou Institute for Food Inspection, Guangzhou 511410, China.
  • Wang Y; Guangzhou Institute for Food Inspection, Guangzhou 511410, China.
  • Li X; Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China.
Foods ; 13(9)2024 May 05.
Article en En | MEDLINE | ID: mdl-38731787
ABSTRACT
Herein, a catalytic amplification enhanced dual-signal immunochromatographic assay (ICA) based on Pt nanoparticles (Pt NPs) modified with Ti3C2Tx MXene (Ti3C2Tx@Pt) was first developed for chloramphenicol (CAP) in animal-derived foods. Due to the large specific surface area and abundant active sites of Ti3C2Tx@Pt, they can be loaded with hundreds of Pt NPs to enhance their catalytic activity, resulting in a significant increase in the detection sensitivity; the sensitivity was up to 50-fold more sensitive than the reported ICA for CAP. The LODs of the developed method for milk/chicken/fish were 0.01 µg/kg, the LOQs were 0.03 µg/kg and the recovery rates were 80.5-117.0%, 87.2-118.1% and 92.7-117.9%, with corresponding variations ranging from 3.1 to 9.6%, 6.0 to 12.7% and 6.0 to 13.6%, respectively. The linear range was 0.0125-1.0 µg/kg. The results of the LC-MS/MS confirmation test on 30 real samples had a good correlation with that of our established method (R2 > 0.98), indicating the practical reliability of the established method. The above results indicated that an ICA based on the Ti3C2Tx@Pt nanozyme has excellent potential as a food safety detection tool.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Foods Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Foods Año: 2024 Tipo del documento: Article