Your browser doesn't support javascript.
loading
Reliability of Spatiotemporal Characteristics During Single-Legged Hop and Bilateral Drop Jump Tasks Using an Instrumented Pressure Walkway.
McManigal, Matthew; Post, Austin; Allen, Michael; Jorgensen, Alyx; Rosenthal, MIke; Wellsandt, Michael; Tao, Matthew; Wellsandt, Elizabeth.
Afiliación
  • McManigal M; Physical Therapy Education University of Nebraska Medical Center.
  • Post A; Department of Orthopaedic Surgery and Rehabilitation University of Nebraska Medical Center.
  • Allen M; College of Education, Health, and Human Sciences University of Nebraska at Omaha.
  • Jorgensen A; Department of Health and Rehabilitation Sciences University of Nebraska Medical Center.
  • Rosenthal M; Department of Health and Rehabilitation Sciences University of Nebraska Medical Center.
  • Wellsandt M; Department of Health and Rehabilitation Sciences University of Nebraska Medical Center.
  • Tao M; Department of Orthopaedic Surgery and Rehabilitation University of Nebraska Medical Center.
  • Wellsandt E; Department of Health and Rehabilitation Sciences University of Nebraska Medical Center.
Int J Sports Phys Ther ; 19(6): 704-713, 2024.
Article en En | MEDLINE | ID: mdl-38835980
ABSTRACT

Background:

Single-legged hop tests have been widely used to assess performance-based outcomes after anterior cruciate ligament (ACL) reconstruction. Traditional single, triple, or 6-meter (6m) timed hop tests only measure distance or time as the principal variables, neglecting other variables, such as individual hop distances within a series of hops, flight time, and stance time. The development of portable instrumented pressure walkways has made it possible to collect parameters such as hop velocity, flight time, stance time, distance, and pressure outside of a laboratory setting. However, the reliability of instrumented pressure walkways in measuring spatial and temporal variables during single-legged hop tests is unknown. This study aimed to determine if the Zeno walkway can reliably measure spatiotemporal (ST) characteristics of hop tests. Study

Design:

Cross-Sectional Study.

Methods:

Individuals (n=38) in this cross-sectional study performed single, triple, and 6m hop tests on a pressure-sensitive Zeno walkway. Twenty-one participants completed follow-up testing between one and 14 days later. Intraclass correlation coefficients (ICC(3,k)) were used to assess test-retest reliability of ST variables. The accuracy of vertical jump height and 6m hop timing were also measured.

Results:

All ST variables demonstrated excellent test-retest reliability (ICC > 0.86) with small minimal detectable change (MDC) values during single-legged hop tests. Six-meter hop time and jump height during a bilateral drop jump were also accurately measured by the walkway.

Conclusion:

An instrumented pressure walkway is a novel tool to reliably assess non-traditional parameters of clinically relevant hop and jump tests such as flight time, stance time, and jump height after lower extremity injury, surgery, and rehabilitation. Level of Evidence 3b.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Int J Sports Phys Ther Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Int J Sports Phys Ther Año: 2024 Tipo del documento: Article