Your browser doesn't support javascript.
loading
Nonlinear robust sliding mode - Backstepping hybrid control for WECS -theoretical design and experimental evaluation.
Echiheb, Farah; Elkafazi, Ismail; Bossoufi, Badre; El Bhiri, Brahim; Almalki, Mishari Metab; A H Alghamdi, Thamer.
Afiliación
  • Echiheb F; LIMAS Laboratory, Faculty of Sciences Dhar El Mahraz, Sidi Mohammed Ben Abdellah University Fez, Morocco.
  • Elkafazi I; SMARTilab Laboratory, Moroccan School of Engineering Sciences Rabat, Morocco.
  • Bossoufi B; SMARTilab Laboratory, Moroccan School of Engineering Sciences Rabat, Morocco.
  • El Bhiri B; LIMAS Laboratory, Faculty of Sciences Dhar El Mahraz, Sidi Mohammed Ben Abdellah University Fez, Morocco.
  • Almalki MM; SMARTilab Laboratory, Moroccan School of Engineering Sciences Rabat, Morocco.
  • A H Alghamdi T; Department of Electrical Engineering, College of Engineering, Al-Baha University, Al Aqiq, Saudi Arabia.
Heliyon ; 10(11): e31767, 2024 Jun 15.
Article en En | MEDLINE | ID: mdl-38841508
ABSTRACT
This paper proposes a new contribution in the field of optimizing control techniques for wind systems to enhance the quality of the energy produced in the grid. Although the Sliding Mode control technique, whether classical or involving the use of artificial intelligence, has shown interesting results, its main drawback lies in the oscillation phenomenon commonly referred to as "chattering." This phenomenon affects the accuracy and robustness of the system, as well as the parametric variation of the system. In this work, we propose a solution that combines two nonlinear techniques based on the Lyapunov theorem to eliminate the chattering phenomenon. It is a hybrid approach between the Backstepping strategy and the Sliding Mode, aiming to control the active and reactive powers of the doubly fed induction generator (DFIG) connected to the electrical grid by two converters (grid side and machine side). This hybrid technique aims to improve the performance of the wind system in terms of precision errors, stability, as well as active and reactive power. The proposed solution has been validated in the Matlab & Simulink environment to assess the performance and robustness of the proposed model, as well as experimentally validated on a test bench using the DSPACE 1104 card. The obtained results are then compared with other techniques, demonstrating a significant improvement in performance.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Heliyon Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Heliyon Año: 2024 Tipo del documento: Article