A fast thermal desorption unit for micro thermal desorption tubes, Part I: Development of the system and proof of concept measurements with hyper-fast gas chromatography.
Chopra, Miriam D; Menger, Florian A; Duong, Benny; Wüst, Matthias; Boeker, Peter.
Afiliación
  • Chopra MD; Institute of Nutritional and Food Sciences, University of Bonn, Friedrich-Hirzebruch Allee 5, D-53115 Bonn, Germany. Electronic address: miriam.chopra@uni-bonn.de.
  • Menger FA; Institute of Nutritional and Food Sciences, University of Bonn, Friedrich-Hirzebruch Allee 5, D-53115 Bonn, Germany; Chemisches und Veterinäruntersuchungsamt Ostwestfalen-Lippe (CVUA-OWL), Westerfeldstraße 1, D-32758 Detmold, Germany.
  • Duong B; Institute of Nutritional and Food Sciences, University of Bonn, Friedrich-Hirzebruch Allee 5, D-53115 Bonn, Germany; HyperChrom Deutschland GmbH, Konrad-Zuse-Strasse 3, 53347 Alfter, Germany.
  • Wüst M; Institute of Nutritional and Food Sciences, University of Bonn, Friedrich-Hirzebruch Allee 5, D-53115 Bonn, Germany.
  • Boeker P; Institute of Nutritional and Food Sciences, University of Bonn, Friedrich-Hirzebruch Allee 5, D-53115 Bonn, Germany; HyperChrom Deutschland GmbH, Konrad-Zuse-Strasse 3, 53347 Alfter, Germany. Electronic address: boeker@uni-bonn.de.
J Chromatogr A ; 1730: 465039, 2024 Aug 16.
Article en En | MEDLINE | ID: mdl-38901296
ABSTRACT
A system consisting of a thermal desorption unit (TDU) and micro thermal desorption tubes (µTD-tubes, 1.4 mm I.D., 10mg Tenax TA) for fast desorption of analytes was developed for the efficient combination of hyper fast gas chromatography with thermal desorption. The fast desorption is achieved by a significantly reduced thermal mass compared to conventional thermal desorption tubes. Therefore, extremely fast heating and cooling cycles are possible. Proof of concept measurements combining the new setup with a flow-field thermal gradient gas chromatograph (FF-TG-GC) and FID detection show good precision and linearity with R2≥0.995 in the analysis of an n-alkane mix (C8-C20). Thermal desorption occurs within 12s. The impact of reduced µTD-tube dimensions on desorption time, full width at half maximum (FWHM), breakthrough volumes, tube flow rates ergo linear velocities, porosity and back pressure is discussed.