Development of an RP-HPLC Method for Quantifying Diclofenac Diethylamine, Methyl Salicylate, and Capsaicin in Pharmaceutical Formulation and Skin Samples.
AlNahwa, Lubna H M; Ali, Hazim M; Hasanin, Tamer H A; Shalaby, Khaled; Alshammari, Mutairah S; Alsirhani, Alaa M; Mohamed, Sabrein H.
Afiliación
  • AlNahwa LHM; Department of Chemistry, College of Science, Jouf University, P.O. Box 2014, Sakaka 72388, Aljouf, Saudi Arabia.
  • Ali HM; Department of Chemistry, College of Science, Jouf University, P.O. Box 2014, Sakaka 72388, Aljouf, Saudi Arabia.
  • Hasanin THA; Department of Chemistry, College of Science, Jouf University, P.O. Box 2014, Sakaka 72388, Aljouf, Saudi Arabia.
  • Shalaby K; Department of Chemistry, Faculty of Science, Minia University, El-Minia 61519, Egypt.
  • Alshammari MS; Department of Pharmaceutics, College of Pharmacy, Jouf University, P.O. Box 2014, Sakaka 72388, Aljouf, Saudi Arabia.
  • Alsirhani AM; Department of Chemistry, College of Science, Jouf University, P.O. Box 2014, Sakaka 72388, Aljouf, Saudi Arabia.
  • Mohamed SH; Department of Chemistry, College of Science, Jouf University, P.O. Box 2014, Sakaka 72388, Aljouf, Saudi Arabia.
Molecules ; 29(12)2024 Jun 08.
Article en En | MEDLINE | ID: mdl-38930798
ABSTRACT
An RP-HPLC method with a UV detector was developed for the simultaneous quantification of diclofenac diethylamine, methyl salicylate, and capsaicin in a pharmaceutical formulation and rabbit skin samples. The separation was achieved using a Thermo Scientific ACCLAIMTM 120 C18 column (Waltham, MA, USA, 4.6 mm × 150 mm, 5 µm). The optimized elution phase consisted of deionized water adjusted to pH = 3 using phosphoric acid mixed with acetonitrile in a 3565% (v/v) ratio with isocratic elution. The flow rate was set at 0.7 mL/min, and the detection was performed at 205 nm and 25 °C. The method exhibits good linearity for capsaicin (0.05-70.0 µg/mL), methyl salicylate (0.05-100.0 µg/mL), and diclofenac diethylamine (0.05-100.0 µg/mL), with low LOD values (0.0249, 0.0271, and 0.0038 for capsaicin, methyl salicylate, and diclofenac diethylamine, respectively). The RSD% values were below 3.0%, indicating good precision. The overall greenness score of the method was 0.61, reflecting its environmentally friendly nature. The developed RP-HPLC method was successfully applied to analyze Omni Hot Gel® pharmaceutical formulation and rabbit skin permeation samples.