Your browser doesn't support javascript.
loading
PdRuO2/PVP nanomaterial as a highly selective, stable, and applicable potentiometric sensor for the detection of Cr3.
Çevik, Kenan; Yildiz, Ilyas; Yildiz, Adnan; Nas, Mehmet Salih; Alma, Mehmet Hakki; Calimli, Mehmet Harbi.
Afiliación
  • Çevik K; Department of Secondary Science and Mathematics Education, Department of Chemistry Education, Faculty of Education, Yuzuncu Yil University, Van, Türkiye.
  • Yildiz I; Department of Molecular Biology and Genetics, Tokat Gaziosmanpasa University, Tokat, 60000, Türkiye.
  • Yildiz A; Department of Secondary Science and Mathematics Education, Department of Chemistry Education, Faculty of Education, Yuzuncu Yil University, Van, Türkiye.
  • Nas MS; Research Laboratory Application and Research Center (ALUM), Igdir University, Igdir, TR, 76000, Türkiye.
  • Alma MH; Department of Organic Agriculture Management, Faculty of Applied Sciences, Igdir University, Igdir, TR, 76000, Türkiye.
  • Calimli MH; Research Laboratory Application and Research Center (ALUM), Igdir University, Igdir, TR, 76000, Türkiye.
Mikrochim Acta ; 191(8): 467, 2024 Jul 18.
Article en En | MEDLINE | ID: mdl-39023534
ABSTRACT
PdRuO2/PVP nanomaterial was synthesized using a straightforward method and characterized using advanced analytical methods such as TEM, XRD, XPS, elemental mapping and SEM. The synthesized PdRuO2/PVP nanomaterial was used as an ionophore in potentiometric sensor electrodes and successfully adapted to Cr3+ ion detection in a large number of aqueous samples. Several experimental parameters of the PdRuO2/PVP sensor such as potentiometric behavior, selectivity, repeatability, response time, pH, titration, and recovery in real samples were investigated. Potentiometric behavioral characteristics were performed in the concentration range 1 × 10-6-1.0 × 10-1 M. The repeated experiments performed six times showed that there was no deviation in the measurements. The limit of detection of the PdRuO2/PVP potentiometric sensor was very low with a value of 8.6 × 10-8 M. The potentiometric measurements showed that the synthesized PdRuO2/PVP ionophore was highly effective in detecting Cr3+ in a wide pH range of 2.0-8.0 and was found to have a shelf life of over 1 year. As a result, the synthesized PdRuO2/PVP electrode material was found to be highly selective, stable, and applicable for Cr3+ detection.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Mikrochim Acta Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Mikrochim Acta Año: 2024 Tipo del documento: Article