Investigation of Degradation and Biocompatibility of Indirect 3D-Printed Bile Duct Stents.
Lee, Ming-Chan; Pan, Cheng-Tang; Huang, Ruo-Jiun; Ou, Hsin-You; Yu, Chun-Yen; Shiue, Yow-Ling.
Afiliación
  • Lee MC; Department of Electrical Engineering, National Kaohsiung University of Science and Technology, Kaohsiung 807, Taiwan.
  • Pan CT; Department of Mechanical and Electro-Mechanical Engineering, National Sun Yat-sen University, Kaohsiung 804, Taiwan.
  • Huang RJ; Institute of Advanced Semiconductor Packaging and Testing, College of Semiconductor and Advanced Technology Research, National Sun Yat-sen University, Kaohsiung 804, Taiwan.
  • Ou HY; Institute of Precision Medicine, National Sun Yat-sen University, Kaohsiung 804, Taiwan.
  • Yu CY; Taiwan Instrument Research Institute, National Applied Research Laboratories, Hsinchu City 300, Taiwan.
  • Shiue YL; Department of Mechanical and Electro-Mechanical Engineering, National Sun Yat-sen University, Kaohsiung 804, Taiwan.
Bioengineering (Basel) ; 11(7)2024 Jul 19.
Article en En | MEDLINE | ID: mdl-39061813
ABSTRACT
This study proposes a bile duct stent based on indirect 3D printing technology. Four ratio materials were synthesized from lactic acid (LA) and glycolide (GA) monomers by melt polymerization PLA, PLGA (7030), PLGA (5050), and PLGA (3070). The four kinds of material powders were preliminarily degraded, and the appearance was observed with an optical microscope (OM) and a camera. The weight and appearance of the four materials changed significantly after four weeks of degradation, which met the conditions for materials to be degraded within 4-6 weeks. Among them, PLGA (5050) lost the most-the weight dropped to 13.4%. A stent with an outer diameter of 10 mm and an inner diameter of 8 mm was successfully manufactured by indirect 3D printing technology, demonstrating the potential of our research. Then, the degradation experiment was carried out on a cylindrical stent with a diameter of 6 mm and a height of 3 mm. The weight loss of the sample was less than that of the powder degradation, and the weight loss of PLGA (5050) was the largest-the weight dropped to 79.6%. The nano-indenter system measured the mechanical properties of materials. Finally, human liver cancer cells Hep-3B were used to conduct in vitro cytotoxicity tests on the scaffolds to test the biocompatibility of the materials. A bile duct stent meeting commercial size requirements has been developed, instilling confidence in the potential of our research for future medical applications.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Bioengineering (Basel) Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Bioengineering (Basel) Año: 2024 Tipo del documento: Article