Your browser doesn't support javascript.
loading
Long-Term Effects of Pulmonary Valve Implantation and Prosthesis Evolution in Patients with Repaired Tetralogy of Fallot. / Efeitos de Longo Prazo do Implante Valvar Pulmonar e Evolução da Prótese em Pacientes com Tetralogia de Fallot Corrigida.
Caneo, Luiz Fernando; Turquetto, Aida Luiza Ribeiro; Boschiero, Matheus Negri; Amato, Luciana Patrick; Ishikawa, Walther Yoshiharu; Hodas, Fabiana Padilha; Ligeiro, Melissa Ganeko; Agostinho, Daniela Regina; Miana, Leonardo Augusto; Tanamati, Carla; Gonçalves, Rilvani Cavalcante; Penha, Juliano Gomes; Massoti, Maria Raquel Brigoni; Jatene, Marcelo Biscegli; Jatene, Fabio Biscegli.
Afiliación
  • Caneo LF; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP - Brasil.
  • Turquetto ALR; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP - Brasil.
  • Boschiero MN; Universidade São Francisco Faculdade de Medicina, Bragança Paulista, SP - Brasil.
  • Amato LP; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP - Brasil.
  • Ishikawa WY; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP - Brasil.
  • Hodas FP; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP - Brasil.
  • Ligeiro MG; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP - Brasil.
  • Agostinho DR; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP - Brasil.
  • Miana LA; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP - Brasil.
  • Tanamati C; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP - Brasil.
  • Gonçalves RC; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP - Brasil.
  • Penha JG; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP - Brasil.
  • Massoti MRB; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP - Brasil.
  • Jatene MB; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP - Brasil.
  • Jatene FB; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP - Brasil.
Arq Bras Cardiol ; 121(7): e20230585, 2024 Jun.
Article en Pt, En | MEDLINE | ID: mdl-39082573
ABSTRACT

BACKGROUND:

Pulmonary valve regurgitation is a significant long-term complication in patients with tetralogy of Fallot (TOF).

OBJECTIVE:

This study aims to investigate the effects of pulmonary valve implantation (PVI) on the anatomy and function of the right ventricle (RV) and the long-term evolution of the implanted prosthesis in the pulmonary position.

METHODS:

A single-center retrospective cohort analysis was performed in 56 consecutive patients with TOF who underwent PVI. The study included patients of both sexes, aged ≥ 12 years, and involved assessing clinical and surgical data, pre- and post-operative cardiovascular magnetic resonance imaging, and echocardiogram data more than 1 year after PVI.

RESULTS:

After PVI, there was a significant decrease in RV end-systolic volume indexed by body surface area (BSA), from 89 mL/BSA to 69 mL/BSA (p < 0.001) and indexed RV end-diastolic volume, from 157 mL/BSA to 116 mL/BSA (p < 0.001). Moreover, there was an increase in corrected RV ejection fraction [ RVEFC = net pulmonary flow (pulmonary forward flow - regurgitant flow) / R V end-diastolic volume ] from 23% to 35% (p < 0.001) and left ventricular ejection fraction from 58% to 60% (p = 0.008). However, a progressive increase in the peak pulmonary valve gradient was observed over time, with 25% of patients experiencing a gradient exceeding 60 mmHg. Smaller prostheses (sizes 19 to 23) were associated with a 4.3-fold higher risk of a gradient > 60 mmHg compared to larger prostheses (sizes 25 to 27; p = 0.029; confidence interval 1.18 to 17.8).

CONCLUSION:

As expected, PVI demonstrated improvements in RV volumes and function. Long-term follow-up and surveillance are crucial for assessing the durability of the prosthesis and detecting potential complications. Proper sizing of prostheses is essential for improved prosthesis longevity.