Your browser doesn't support javascript.
loading
A novel sandwich electrochemical immunosensor utilizing customized template and phosphotungstate catalytic amplification for CD44 detection.
Xia, Ping; Fu, Yuchun; Chen, Qian; Shan, Lianhai; Zhang, Chungu; Feng, Shun.
Afiliación
  • Xia P; Sichuan Engineering Research Center for Biomimetic Synthesis of Natural Drugs, School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China.
  • Fu Y; Sichuan Engineering Research Center for Biomimetic Synthesis of Natural Drugs, School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China.
  • Chen Q; Sichuan Engineering Research Center for Biomimetic Synthesis of Natural Drugs, School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China.
  • Shan L; Sichuan Engineering Research Center for Biomimetic Synthesis of Natural Drugs, School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China.
  • Zhang C; Sichuan Engineering Research Center for Biomimetic Synthesis of Natural Drugs, School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China.
  • Feng S; Sichuan Engineering Research Center for Biomimetic Synthesis of Natural Drugs, School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China. Electronic address: fengshunxd@hotmail.com.
Bioelectrochemistry ; 160: 108787, 2024 Dec.
Article en En | MEDLINE | ID: mdl-39098083
ABSTRACT
A sandwich-type electrochemical immunosensor was proposed for the ultra-sensitive detection of CD44, a potential biomarker for breast cancer. In this design, a customized template-based ionic liquid (1-butyl-2,3-dimethylimidazolium tetrafluoroborate) carbon paste electrode (CILE) served as the sensing platform, and thionine/Au nanoparticles/covalent-organic frameworks (THI/Au/COF) were used as the signal label. Moreover, an enzyme-free signal amplification strategy was introduced by involving H2O2 and phosphotungstate (PW12) with peroxidase-like activity. Under optimized conditions, the linear range is as wide as six orders of magnitude, and the detection limit is as low as 0.71 pg mL-1 (estimated based on S/N = 3). Average recoveries range from 98.16 %-100.1 %, with a relative standard deviation (RSD) of 1.42-8.27 % in mouse serum, and from 98.44 %-99.06 %, with an RSD of 1.14-4.84 % (n = 3) in artificial saliva. Furthermore, the immunosensor exhibits excellent specificity toward CD44, good stability, and low cost, indicating great potential for application in clinical trials.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Receptores de Hialuranos / Técnicas Electroquímicas / Límite de Detección Idioma: En Revista: Bioelectrochemistry Asunto de la revista: BIOQUIMICA Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Receptores de Hialuranos / Técnicas Electroquímicas / Límite de Detección Idioma: En Revista: Bioelectrochemistry Asunto de la revista: BIOQUIMICA Año: 2024 Tipo del documento: Article