Your browser doesn't support javascript.
loading
Combining array tomography with electron tomography provides insights into leakiness of the blood-brain barrier in mouse cortex.
Kislinger, Georg; Fabig, Gunar; Wehn, Antonia; Rodriguez, Lucia; Jiang, Hanyi; Niemann, Cornelia; Klymchenko, Andrey S; Plesnila, Nikolaus; Misgeld, Thomas; Müller-Reichert, Thomas; Khalin, Igor; Schifferer, Martina.
Afiliación
  • Kislinger G; Institute of Neuronal Cell Biology, Technical University Munich, Munich, Germany.
  • Fabig G; German Center for Neurodegenerative Diseases (DZNE), Munich, Germany.
  • Wehn A; Experimental Center, Faculty of Medicine Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.
  • Rodriguez L; Institute for Stroke and Dementia Research (ISD), LMU University Hospital, LMU Munich, Munich, Germany.
  • Jiang H; Department of Neurosurgery, University of Munich Medical Center, Munich, Germany.
  • Niemann C; Institute of Neuronal Cell Biology, Technical University Munich, Munich, Germany.
  • Klymchenko AS; German Center for Neurodegenerative Diseases (DZNE), Munich, Germany.
  • Plesnila N; Institute of Neuronal Cell Biology, Technical University Munich, Munich, Germany.
  • Misgeld T; German Center for Neurodegenerative Diseases (DZNE), Munich, Germany.
  • Müller-Reichert T; Department of Psychiatry and Psychotherapy, University Medicine Greifswald, Greifswald, Germany.
  • Khalin I; Institute of Neuronal Cell Biology, Technical University Munich, Munich, Germany.
  • Schifferer M; German Center for Neurodegenerative Diseases (DZNE), Munich, Germany.
Elife ; 122024 Aug 05.
Article en En | MEDLINE | ID: mdl-39102289
ABSTRACT
Like other volume electron microscopy approaches, automated tape-collecting ultramicrotomy (ATUM) enables imaging of serial sections deposited on thick plastic tapes by scanning electron microscopy (SEM). ATUM is unique in enabling hierarchical imaging and thus efficient screening for target structures, as needed for correlative light and electron microscopy. However, SEM of sections on tape can only access the section surface, thereby limiting the axial resolution to the typical size of cellular vesicles with an order of magnitude lower than the acquired xy resolution. In contrast, serial-section electron tomography (ET), a transmission electron microscopy-based approach, yields isotropic voxels at full EM resolution, but requires deposition of sections on electron-stable thin and fragile films, thus making screening of large section libraries difficult and prone to section loss. To combine the strength of both approaches, we developed 'ATUM-Tomo, a hybrid method, where sections are first reversibly attached to plastic tape via a dissolvable coating, and after screening detached and transferred to the ET-compatible thin films. As a proof-of-principle, we applied correlative ATUM-Tomo to study ultrastructural features of blood-brain barrier (BBB) leakiness around microthrombi in a mouse model of traumatic brain injury. Microthrombi and associated sites of BBB leakiness were identified by confocal imaging of injected fluorescent and electron-dense nanoparticles, then relocalized by ATUM-SEM, and finally interrogated by correlative ATUM-Tomo. Overall, our new ATUM-Tomo approach will substantially advance ultrastructural analysis of biological phenomena that require cell- and tissue-level contextualization of the finest subcellular textures.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Barrera Hematoencefálica / Tomografía con Microscopio Electrónico Idioma: En Revista: Elife Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Barrera Hematoencefálica / Tomografía con Microscopio Electrónico Idioma: En Revista: Elife Año: 2024 Tipo del documento: Article