Your browser doesn't support javascript.
loading
Characterization and Quantification of Naphthenic Acids in Produced Water by Orbitrap MS and a Multivariate Approach.
Valente Roque, Jussara; Rodrigues, Marcella Ferreira; M Dufrayer, Gabriel Henry; Medeiros Júnior, Iris; de Carvalho, Rogério Mesquita; da Silva Lima, Gesiane; Dos Santos, Gabriel Franco; Vaz, Boniek Gontijo.
Afiliación
  • Valente Roque J; Institute of Chemistry, Federal University of Goiás, Goiânia, GO 74690-900, Brazil.
  • Rodrigues MF; Institute of Chemistry, Federal University of Goiás, Goiânia, GO 74690-900, Brazil.
  • M Dufrayer GH; Institute of Chemistry, Federal University of Goiás, Goiânia, GO 74690-900, Brazil.
  • Medeiros Júnior I; CENPES, PETROBRAS, Rio de Janeiro, RJ 21941-915, Brazil.
  • de Carvalho RM; CENPES, PETROBRAS, Rio de Janeiro, RJ 21941-915, Brazil.
  • da Silva Lima G; Institute of Chemistry, Federal University of Goiás, Goiânia, GO 74690-900, Brazil.
  • Dos Santos GF; Institute of Chemistry, Federal University of Goiás, Goiânia, GO 74690-900, Brazil.
  • Vaz BG; Institute of Chemistry, Federal University of Goiás, Goiânia, GO 74690-900, Brazil.
Article en En | MEDLINE | ID: mdl-39180744
ABSTRACT
Naphthenic acids (NAs) naturally occur in crude oil and its associated produced water, presenting significant challenges, such as corrosion, in refinery apparatus and ecotoxicity in aquatic habitats. This study delineates a multivariate method to quantify NAs in produced water via electrospray ionization coupled with high-resolution Orbitrap mass spectrometry (ESI-Orbitrap MS). By employing liquid-liquid extraction, followed by direct infusion ESI(-)-Orbitrap MS, we characterized and quantified NAs employing a partial least-squares regression (PLS) model enhanced by the ordered predictor selection (OPS) algorithm. Thirty-six produced water samples were utilized, with 24 allocated for calibration and 12 designated for validation. The PLS-OPS model demonstrated notable accuracy in predicting NA concentrations in simulated and actual produced water samples ranging from ∼30 to 300 mg·L-1. This methodology offers a rapid yet robust alternative for quantifying NAs using mass spectrometry augmented by PLS and the OPS. Its significance is underscored by its potential to equip the petroleum industry with a swift and reliable monitoring mechanism for NAs in produced water, thereby aiding in mitigating environmental and operational risks.

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: J Am Soc Mass Spectrom Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: J Am Soc Mass Spectrom Año: 2024 Tipo del documento: Article