Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 382(13): 1208-1218, 2020 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-32050061

RESUMEN

BACKGROUND: Polymer-free drug-coated stents provide superior clinical outcomes to bare-metal stents in patients at high bleeding risk who undergo percutaneous coronary intervention (PCI) and are treated with 1 month of dual antiplatelet therapy. Data on the use of polymer-based drug-eluting stents, as compared with polymer-free drug-coated stents, in such patients are limited. METHODS: In an international, randomized, single-blind trial, we compared polymer-based zotarolimus-eluting stents with polymer-free umirolimus-coated stents in patients at high bleeding risk. After PCI, patients were treated with 1 month of dual antiplatelet therapy, followed by single antiplatelet therapy. The primary outcome was a safety composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year. The principal secondary outcome was target-lesion failure, an effectiveness composite of death from cardiac causes, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. Both outcomes were powered for noninferiority. RESULTS: A total of 1996 patients at high bleeding risk were randomly assigned in a 1:1 ratio to receive zotarolimus-eluting stents (1003 patients) or polymer-free drug-coated stents (993 patients). At 1 year, the primary outcome was observed in 169 of 988 patients (17.1%) in the zotarolimus-eluting stent group and in 164 of 969 (16.9%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% confidence interval [CI], 3.5; noninferiority margin, 4.1; P = 0.01 for noninferiority). The principal secondary outcome was observed in 174 patients (17.6%) in the zotarolimus-eluting stent group and in 169 (17.4%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% CI, 3.5; noninferiority margin, 4.4; P = 0.007 for noninferiority). CONCLUSIONS: Among patients at high bleeding risk who received 1 month of dual antiplatelet therapy after PCI, use of polymer-based zotarolimus-eluting stents was noninferior to use of polymer-free drug-coated stents with regard to safety and effectiveness composite outcomes. (Funded by Medtronic; ONYX ONE ClinicalTrials.gov number, NCT03344653.).


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Inmunosupresores/administración & dosificación , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/uso terapéutico , Polímeros , Sirolimus/análogos & derivados , Trombosis Coronaria/etiología , Trombosis Coronaria/mortalidad , Quimioterapia Combinada , Stents Liberadores de Fármacos/efectos adversos , Cardiopatías/mortalidad , Hemorragia/inducido químicamente , Humanos , Estimación de Kaplan-Meier , Inhibidores de Agregación Plaquetaria/efectos adversos , Diseño de Prótesis , Método Simple Ciego , Sirolimus/administración & dosificación
2.
Catheter Cardiovasc Interv ; 97(3): 423-430, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-32243050

RESUMEN

AIM: The TAXCO study was designed to compare the degree of neointimal coverage and the prevalence of malapposition at 6 months subsequent to implantation of ultrathin biodegradable polymer-coated sirolimus-eluting stents (SES) and durable polymer-coated everolimus-eluting stents (EES) of thin strut thickness using optical coherence tomography (OCT). METHODS: The TAXCO study included a total of 42 patients who gave consent and underwent OCT examination between August 2017 and September 2017. Of 42, five patients' OCT examinations were of insufficient quality for quantitative analysis. Thus, the OCT analysis group consisted of 37 patients. Among them, 16 patients were treated with Xience (Abbott Vascular) and 21 with Tetriflex (Sahajanand Medical Technologies Pvt. Ltd., Surat, India), 6 (±1) months earlier at our institution. The OCT was performed using a C7 Dragonfly™ imaging catheter (St. Jude Medical Inc.). All OCT images were analyzed at an independent core laboratory (Cardiovascular Research Center, São Paulo, Brazil) by analysts who were blinded to patient and procedural information. RESULTS: A total of 763 crosssections (6,882 struts) were analyzed in Xience group, and 1,127 crosssections (9,968 struts) in Tetriflex group. At 6 months, on per-lesion basis, no significant differences were observed between Xience group and Tetriflex group in mean percentage of uncovered struts (1.87 ± 3.86 vs. 2.42 ± 3.46, p = .137) and malapposed struts (0.05 ± 0.2 vs. 0.21 ± 0.69, p = .302). Strut-level neointimal thickness also did not differ between Xience group and Tetriflex group (0.18 ± 0.12 vs. 0.14 ± 0.08 mm, p = .286). CONCLUSION: This OCT study found no significant difference in strut coverage and neointimal thickness at 6 months after implantation of biodegradable polymer-coated Tetriflex, when compared with durable polymer-coated Xience.


Asunto(s)
Stents Liberadores de Fármacos , Odonata , Intervención Coronaria Percutánea , Implantes Absorbibles , Animales , Everolimus , Estudios de Seguimiento , Humanos , Neointima , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Sirolimus , Stents , Tomografía de Coherencia Óptica , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 98(7): 1335-1342, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-33247618

RESUMEN

AIMS: The aim of SiBi study was to evaluate the early vascular healing and neointimal coverage after implantation of ultrathin (60 µm) biodegradable polymer-coated Tetriflex (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) sirolimus-eluting stent (SES) using optical coherence tomography (OCT) at 4 to 6 weeks after implantation. METHODS: SiBi was a single-center, observational, investigator-initiated study. From January 15, 2018 to April 15, 2018, total 29 consecutive patients who had consented and underwent OCT examination at 4-6 weeks after Tetriflex SES implantation were enrolled. All OCT images were analyzed at an independent core laboratory by analysts who were blinded to patient and procedural information. RESULTS: Of 29 patients, four patients were excluded, as those OCT images were technically inadequate for analysis. Therefore, 25 patients were included in final OCT analysis. Average OCT analysis was performed after 35.3 ± 5 days of Tetriflex implantation. Total 14,024 stent struts in 1,520 cross sections were analyzed. Strut tissue coverage was observed in 91.26 ± 5.53% of struts and malapposed struts were seen in 0.89 ± 1.67%. The mean neointimal hyperplasia (NIH) thickness on the covered struts was 50 ± 30 µm. CONCLUSION: A large percentage of struts were found to be covered with thin layer of NIH evenly distributed along the stent length at around 1 month from stent implantation. The results of this pilot study serve as ethical and scientific backbone to conduct an adequately powered clinical trial to evaluate outcomes of short dual-antiplatelet therapy in context of ultrathin strut stent.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Humanos , Neointima , Proyectos Piloto , Polímeros , Sirolimus , Stents , Tomografía de Coherencia Óptica , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 93(1): E1-E7, 2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30286520

RESUMEN

BACKGROUND: There is still limited data on the very long term clinical outcomes after ABSORB BRS in daily practice. We sought to evaluate the 3 year-performance of the Absorb bioresorbable vascular scaffolds for the treatment of low/moderate complexity patients enrolled in the ABSORB EXTEND trial. METHODS: ABSORB EXTEND is a prospective, single-arm, open-label clinical study in which 812 patients were enrolled at 56 sites. This study allowed the treatment of lesions ≤28 mm in length and reference vessel diameter of 2.0-3.8 mm (as assessed by on-line QCA). To determine the independent predictors of MACE, a multivariable logistic regression model was built using a stepwise (forward/backward) procedure. RESULTS: Average population age was 61 years and 26.5% had diabetes. Most patients had single target lesion (92.4%). Adequate scaffold deployment (PSP) was achieved in 14.2% of the cases. At three years, the composite endpoints of MACE and ischemia-driven target vessel failure were 9.2% and 10.6%, respectively. The cumulative rate of ARC definite/probable thrombosis was 2.2%, with 1.2% of the cases occurring after the 1st year. Independent predictors of MACE were hypertension and the need for "bail out" stent. CONCLUSION: At three-year follow-up, the use of ABSORB in low/moderate complex PCI was associated with low and acceptable rates of major adverse clinical events, despite the infrequent use of the recommended contemporary scaffold deployment technique. However, scaffold thrombosis rate was higher than reported with current generation of metallic DES. The study is registered on clinicaltrials.gov (unique identifier NCT01023789).


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/epidemiología , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
5.
N Engl J Med ; 373(21): 2038-47, 2015 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-26466021

RESUMEN

BACKGROUND: Patients at high risk for bleeding who undergo percutaneous coronary intervention (PCI) often receive bare-metal stents followed by 1 month of dual antiplatelet therapy. We studied a polymer-free and carrier-free drug-coated stent that transfers umirolimus (also known as biolimus A9), a highly lipophilic sirolimus analogue, into the vessel wall over a period of 1 month. METHODS: In a randomized, double-blind trial, we compared the drug-coated stent with a very similar bare-metal stent in patients with a high risk of bleeding who underwent PCI. All patients received 1 month of dual antiplatelet therapy. The primary safety end point, tested for both noninferiority and superiority, was a composite of cardiac death, myocardial infarction, or stent thrombosis. The primary efficacy end point was clinically driven target-lesion revascularization. RESULTS: We enrolled 2466 patients. At 390 days, the primary safety end point had occurred in 112 patients (9.4%) in the drug-coated-stent group and in 154 patients (12.9%) in the bare-metal-stent group (risk difference, -3.6 percentage points; 95% confidence interval [CI], -6.1 to -1.0; hazard ratio, 0.71; 95% CI, 0.56 to 0.91; P<0.001 for noninferiority and P=0.005 for superiority). During the same time period, clinically driven target-lesion revascularization was needed in 59 patients (5.1%) in the drug-coated-stent group and in 113 patients (9.8%) in the bare-metal-stent group (risk difference, -4.8 percentage points; 95% CI, -6.9 to -2.6; hazard ratio, 0.50; 95% CI, 0.37 to 0.69; P<0.001). CONCLUSIONS: Among patients at high risk for bleeding who underwent PCI, a polymer-free umirolimus-coated stent was superior to a bare-metal stent with respect to the primary safety and efficacy end points when used with a 1-month course of dual antiplatelet therapy. (Funded by Biosensors Europe; LEADERS FREE ClinicalTrials.gov number, NCT01623180.).


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Inmunosupresores/administración & dosificación , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/uso terapéutico , Sirolimus/análogos & derivados , Anciano , Terapia Combinada , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Método Doble Ciego , Stents Liberadores de Fármacos/efectos adversos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Polímeros , Diseño de Prótesis , Sirolimus/administración & dosificación , Stents/efectos adversos
6.
Catheter Cardiovasc Interv ; 91(6): 1084-1091, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-28843033

RESUMEN

BACKGROUND: The shear stress distribution assessment can provide useful insights for the hemodynamic performance of the implanted stent/scaffold. Our aim was to investigate the effect of a novel bioresorbable scaffold, Mirage on local hemodynamics in animal models. METHOD: The main epicardial coronary arteries of 7 healthy mini-pigs were implanted with 11 Mirage Microfiber sirolimus-eluting Bioresorbable Scaffolds (MMSES). Optical coherence tomography (OCT) was performed post scaffold implantation and the obtained images were fused with angiographic data to reconstruct the coronary artery anatomy. Blood flow simulation was performed and Endothelial Shear Stress(ESS) distribution was estimated for each of the 11 scaffolds. ESS data were extracted in each circumferential 5-degree subunit of each cross-section in the scaffolded segment. The generalized linear mixed-effect analysis was implemented for the comparison of ESS in two scaffold groups; 150-µm strut thickness MMSES and 125-µm strut thickness MMSES. RESULTS: ESS was significantly higher in MMSES (150 µm) [0.85(0.49-1.40) Pa], compared to MMSES (125 µm) [0.68(0.35-1.18) Pa]. Both MMSES (150 µm) and MMSES (125 µm) revealed low recirculation zone percentages per luminal surface area [3.17% ± 1.97% in MMSES (150 µm), 2.71% ± 1.32% in MMSES (125 µm)]. CONCLUSION: Thinner strut Mirage scaffolds induced lower shear stress due to the small size vessels treated as compared to the thick strut version of the Mirage which was implanted in relatively bigger size vessels. Vessel size should be taken into account in planning BRS implantation. Small vessels may not get benefit from BRS implantation even with a streamlined strut profile. This pilot study warrants comparative assessment with commercially available bioresorbable scaffolds.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Vasos Coronarios/cirugía , Hemodinámica , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Animales , Velocidad del Flujo Sanguíneo , Simulación por Computador , Circulación Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Modelos Animales , Modelos Cardiovasculares , Diseño de Prótesis , Estrés Mecánico , Porcinos , Porcinos Enanos , Factores de Tiempo , Tomografía de Coherencia Óptica
7.
Catheter Cardiovasc Interv ; 92(6): E368-E374, 2018 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-29521477

RESUMEN

INTRODUCTION: Bioresorbable coronary scaffolds (BRS) have been developed to increase the late safety of coronary angioplasty by providing transitory coronary support and then being fully incorporated to the vessel wall. In the present trial, we sought to evaluate the performance and changes over time in the DESolve™ novolimus-eluting BRS using serial intravascular ultrasound (IVUS) in patients submitted to percutaneous coronary interventions. METHODS: Single-center, prospective, non-randomized study involving 17 consecutive patients submitted to implantation of the DESolve™ scaffold and serial evaluated with IVUS at different time points (post procedure, 6 and 18 months). Primary endpoint included the variation in lumen, scaffold, and vessel diameter and area along the months. RESULTS: Angiographic success was achieved in all cases. Scaffold area and volume on IVUS were significantly greater at 6 months than at baseline (6.41 ± 1.35 mm2 vs. 7.35 ± 1.53 mm2 , P < 0.002; and 101.19 ± 20.9 mm3 vs. 118.51 ± 26.6 mm3 , P = 0.001). Late lumen loss was 0.22 ± 0.30 mm at 6 months and 0.33 ± 0.44 mm at 18 months. No major adverse cardiac events occurred. At late follow-up (18 months) the scaffold was not visualized by IVUS; therefore the evaluation was restricted to lumen and vessel at that time point. CONCLUSIONS: IVUS serial evaluation of the novel DESolve BRS showed an increase in the device dimensions between baseline and 6 months, with concomitant enlargement of lumen dimensions and effective suppression of neointimal proliferation. At 18 months, no footprint of the scaffold was detected and the initial lumen enlargement was sustained.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Macrólidos/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Ultrasonografía Intervencional , Anciano , Fármacos Cardiovasculares/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Macrólidos/efectos adversos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
8.
Lancet ; 387(10013): 31-9, 2016 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-26470647

RESUMEN

BACKGROUND: Absorbable scaffolds were designed to overcome the limitations of conventional, non-absorbable metal-based drug-eluting stents. So far, only polymeric absorbable scaffolds are commercially available. We aimed to assess the safety and performance of a novel second-generation drug-eluting absorbable metal scaffold (DREAMS 2G) in patients with de-novo coronary artery lesions. METHODS: We did this prospective, multicentre, non-randomised, first-in-man trial at 13 percutaneous coronary intervention centres in Belgium, Brazil, Denmark, Germany, Singapore, Spain, Switzerland, and the Netherlands. Eligible patients had stable or unstable angina or documented silent ischaemia, and a maximum of two de-novo lesions with a reference vessel diameter between 2·2 mm and 3·7 mm. Clinical follow-up was scheduled at months 1, 6, 12, 24, and 36. Patients were scheduled for angiographic follow-up at 6 months, and a subgroup of patients was scheduled for intravascular ultrasound, optical coherence tomography, and vasomotion assessment. All patients were recommended to take dual antiplatelet treatment for at least 6 months. The primary endpoint was in-segment late lumen loss at 6 months. We did analysis by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT01960504. FINDINGS: Between Oct 8, 2013, and May 22, 2015, we enrolled 123 patients with 123 coronary target lesions. At 6 months, mean in-segment late lumen loss was 0·27 mm (SD 0·37), and angiographically discernable vasomotion was documented in 20 (80%) of 25 patients. Intravascular ultrasound assessments showed a preservation of the scaffold area (mean 6·24 mm(2) [SD 1·15] post-procedure vs 6·21 mm(2) [1·22] at 6 months) with a low mean neointimal area (0·08 mm(2) [0·09]), and optical coherence tomography did not detect any intraluminal mass. Target lesion failure occurred in four (3%) patients: one (<1%) patient died from cardiac death, one (<1%) patient had periprocedural myocardial infarction, and two (2%) patients needed clinically driven target lesion revascularisation. No definite or probable scaffold thrombosis was observed. INTERPRETATION: Our findings show that implantation of the DREAMS 2G device in de-novo coronary lesions is feasible, with favourable safety and performance outcomes at 6 months. This novel absorbable metal scaffold could be an alternative to absorbable polymeric scaffolds for treatment of obstructive coronary disease. FUNDING: Biotronik AG.


Asunto(s)
Implantes Absorbibles , Antibióticos Antineoplásicos/uso terapéutico , Reestenosis Coronaria/patología , Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Sirolimus/uso terapéutico , Andamios del Tejido , Anciano , Aleaciones , Estudios de Cohortes , Reestenosis Coronaria/diagnóstico por imagen , Endosonografía , Femenino , Humanos , Magnesio , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea , Estudios Prospectivos , Tomografía de Coherencia Óptica , Resultado del Tratamiento
9.
Catheter Cardiovasc Interv ; 88(1): 51-9, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26331782

RESUMEN

BACKGROUND: Scoring balloons produce excellent acute results in the treatment of in-stent restenosis (ISR), fibro-calcific and bifurcation lesions but have not been shown to affect the restenosis rate. A novel paclitaxel-coated scoring balloon (SB) was developed and tested to overcome this limitation. METHODS AND RESULTS: SB were coated with paclitaxel admixed with a specific excipient. Patients at four clinical sites in Germany and one in Brazil with ISR of coronary bare metal stent (BMS) were randomized 1:1 to treatment with either a drug-coated or uncoated SB. Baseline and 6-month follow-up quantitative coronary angiography was performed by an independent blinded core lab and all patients will be evaluated clinically for up to one year. The primary endpoint was angiographic in-segment late lumen loss (LLL). Secondary endpoints included the rate of clinically driven target lesion revascularization (TLR), composite of major adverse cardiovascular events (MACE), stent thrombosis and other variables. Sixty-one patients were randomized (28 uncoated and 33 drug-coated SB); mean age 65 years, males 72%, and presence of diabetes 39%. At 6-month angiography, in-segment LLL was 0.48 ± 0.51 mm in the uncoated SB group versus 0.17 ± 0.40 mm in the drug-coated SB group (P = 0.01; ITT analysis). The rate of binary restenosis was 41% in the uncoated SB group versus 7% in the drug-coated SB group (P = 0.004). The MACE rate was 32% with the uncoated SB vs. 6% in the drug-coated SB group (P = 0.016). This difference was primarily due to the reduced need for clinically driven TLR in the coated SB group (3% vs. 32% P = 0.004). CONCLUSIONS: A novel paclitaxel-coated coronary SB has been developed and successfully used in a first-in-human randomized controlled trial [ClinicalTrials.gov Identifier: NCT01495533]. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/terapia , Paclitaxel/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Stents , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Brasil , Fármacos Cardiovasculares/efectos adversos , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Femenino , Alemania , Humanos , Masculino , Metales , Persona de Mediana Edad , Paclitaxel/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Retratamiento , Factores de Tiempo , Tomografía de Coherencia Óptica , Resultado del Tratamiento
10.
Catheter Cardiovasc Interv ; 83(1): 19-24, 2014 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-23413202

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the Sparrow sirolimus-eluting stent (Sparrow-SES) against the Sparrow bare-metal stent (Sparrow-BMS) and conventional balloon-expandable bare-metal stent (BMS: Driver/Micro-Driver stent, Medtronic Vascular, Santa Rosa, CA). BACKGROUND: The Sparrow stent (Biosensors International, Singapore) consists of a guide wire-based, self-expandable, ultra-thin nitinol stent. The performance of this device with sirolimus in a fully biodegradable polymer has not been determined. METHODS: A total of 74 patients were included in this intravascular ultrasound (IVUS) sub-study of the CARE II trial, which was a prospective, randomized, multicenter trial in the treatment of single de novo native coronary artery lesions in vessels ranging from 2.0 mm to 2.75 mm in diameter (Sparrow-SES: n = 31, Sparrow-BMS: n = 22, BMS: n = 21). RESULTS: Stent volume index (VI) was significantly increased 8-month later in Sparrow-SES and Sparrow-BMS, but not in BMS (4.0 ± 1.0 to 4.6 ± 1.0 mm(3) /mm, p<0.0001, 4.0 ± 0.6 to 4.4 ± 0.8 mm(3) /mm, p<0.05, and 5.2 ± 1.0 to 5.1 ± 0.9 mm(3) /mm, p=0.421, respectively). % neointimal obstruction in Sparrow-SES was significantly smaller than those in Sparrow-BMS and BMS at follow-up (17.6 ± 9.4 vs. 36.2 ± 13.8 and 39.9 ± 11.1%, p<0.001). Sparrow-SES showed a mean 15% stent expansion and good suppression of neointimal proliferation, resulting in a significantly lower percentage of change in lumen VI during follow-up period (Sparrow-SES: -6.2 ± 16.2%, Sparrow-BMS: -30.4 ± 11.6%, BMS: -40.4 ± 10.0%, p<0.001). CONCLUSIONS: The self-expanding Sparrow-SES demonstrated chronic stent expansion, good suppression of neointimal proliferation and resulted in a more preserved lumen in stented small vessels compared with the Sparrow-BMS and conventional balloon expandable BMS.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Sirolimus/administración & dosificación , Stents , Ultrasonografía Intervencional , Anciano , Aleaciones , Angioplastia Coronaria con Balón/efectos adversos , Proliferación Celular , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/prevención & control , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neointima , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento
11.
Catheter Cardiovasc Interv ; 84(7): 1073-9, 2014 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-23460415

RESUMEN

AIM: We sought to assess the long term efficacy of the novel VESTAsync™ Eluting Stent (VES) combining a Cro-Co platform with a nanothin-microporous hydroxyapatite surface coating impregnated with a polymer-free low-dose of Sirolimus (55 µg). METHODS: The Vestasync II trial was a randomized (2:1), double-blinded, multicenter comparison of the VES to its platform, the Gen X stent, with microporous hydroxyapatite surface coating without sirolimus. Patients were eligible if they presented de novo lesions in native coronary arteries with 3.0-3.5 mm diameter and ≤ 14 mm in length. Primary endpoint was 8-month in-stent late loss and % of stent obstruction. Lifelong aspirin and 6-month clopidogrel were prescribed to all patients. RESULTS: Seventy-five patients were enrolled (VES = 50 pts). Baseline characteristics included mean age of 58 years and 29% of diabetics. Reference vessel diameter and lesion length were 2.8 ± 0.4 mm and 13.0 ± 2.0 mm, respectively. In-stent late loss (0.39 ± 0.20 vs. 0.74 ± 0.52, P = 0.03) and % of neointima hyperplasia (9.3 ± 6.6% vs. 17.6 ± 9.4%, P = 0.0016) were significantly reduced in the VES cohort. Up to 1 year, there was a single case of myocardial infarction and one target lesion revascularization (TLR) (2%) in the VES group while in the control cohort there were one TLR (4%) and one cardiac death (4%). CONCLUSION: The VestSync II trial is a proof-of-concept study and demonstrates the sustained efficacy of this novel polymer-free sirolimus drug-eluting stents. A larger trial, with more complex lesions, clinical endpoints and longer FU period is warranted. © 2013 Wiley Periodicals, Inc.


Asunto(s)
Materiales Biocompatibles Revestidos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Stents , Ultrasonografía Intervencional/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Método Doble Ciego , Stents Liberadores de Fármacos , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento
12.
JACC Cardiovasc Interv ; 15(11): 1153-1163, 2022 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-35680195

RESUMEN

BACKGROUND: Resolute Onyx polymer-based zotarolimus-eluting stents (ZES) were noninferior in safety and effectiveness to BioFreedom polymer-free biolimus A9-coated stents (DCS) in high-bleeding-risk (HBR) patients treated with 1-month dual antiplatelet therapy (DAPT) followed by single antiplatelet therapy (SAPT) at 1 year. OBJECTIVES: This study reports the final 2-year results of the randomized Onyx ONE trial. METHODS: The Onyx ONE (A Randomized Controlled Trial With Resolute Onyx in One Month Dual Antiplatelet Therapy (DAPT) for High-Bleeding Risk Patients) trial randomly assigned HBR patients to treatment with ZES or DCS. Following 1-month DAPT, event-free patients received SAPT (either aspirin or a P2Y12 inhibitor at physician discretion). The primary safety endpoint, a composite of cardiac death, myocardial infarction, or stent thrombosis at 1 year, was determined at 1 year. Rates of primary and secondary endpoints were calculated after final follow-up at 2 years. RESULTS: A total of 1,003 patients were randomly allocated to ZES and 993 patients to DCS. Follow-up was complete in 980 (97.7%) ZES patients and 962 (96.9%) DCS patients at 2 years. The primary safety endpoint occurred in 208 (21.2%) patients in the ZES group and 199 (20.7%) patients in the DCS group (risk difference: 0.5%; 95% CI: -3.1% to 4.2%; P = 0.78) at 2 years without significant differences in individual components of the composite endpoint. The secondary effectiveness endpoint occurred in 217 (22.1%) patients in the ZES group and 202 (21.0%) patients in the DCS group (risk difference: 1.1%; 95% CI: -2.5% to 4.8%; P = 0.54). CONCLUSIONS: Among patients at HBR treated with 1-month DAPT followed by SAPT, the Resolute Onyx polymer-based ZES had similar 2-year outcomes for the primary safety and secondary effectiveness endpoint compared with the BioFreedom polymer-free DCS. (A Randomized Controlled Trial With Resolute Onyx in One Month Dual Antiplatelet Therapy [DAPT] for High-Bleeding Risk Patients [Onyx ONE]; NCT03344653).


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Stents Liberadores de Fármacos/efectos adversos , Hemorragia/inducido químicamente , Humanos , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Polímeros , Diseño de Prótesis , Stents/efectos adversos , Resultado del Tratamiento
13.
Catheter Cardiovasc Interv ; 77(1): 49-51, 2011 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-20506126

RESUMEN

At present, percutaneous coronary intervention with drug-eluting stent (DES) implantation represents the default strategy to treat coronary artery disease in many institutions around the world. However, concerns regarding long-term safety of first-generation DES have prompted the development of novel DES systems such as the NEVO (Cordis Corporation, Johnson & Johnson, Warren, NJ) sirolimus-eluting stent with biodegradable polymer and reservoir technology. In the current report, we present, for the first time, a complete midterm invasive assessment of a patient treated with this novel device in the Res-Elution I study.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Materiales Biocompatibles , Fármacos Cardiovasculares/administración & dosificación , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Sirolimus/administración & dosificación , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional , Angioplastia Coronaria con Balón/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/etiología , Reestenosis Coronaria/prevención & control , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Trombosis/diagnóstico , Trombosis/etiología , Trombosis/prevención & control , Factores de Tiempo , Resultado del Tratamiento
14.
Rev Port Cardiol (Engl Ed) ; 40(2): 71-76, 2021 Feb.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-33402278

RESUMEN

INTRODUCTION AND OBJECTIVES: The Stents Coated With the Biodegradable Polymer on Their Abluminal Faces and Elution of Sirolimus Versus Biolimus Elution for the Treatment of de Novo Coronary Lesions - DESTINY Trial is a non-inferiority randomized study that compared the Inspiron™ sirolimus-eluting stent (SES) with the control Biomatrix™ Flex biolimus-eluting stent (BES). Previous reports in the first year showed similar outcomes for both stents, in clinical, angiographic, optical coherence tomography, and intravascular ultrasound assessments. The present analysis aims to compare the clinical performance of these two biodegradable polymer drug-eluting stents five years after the index procedure. METHODS: A total of 170 patients (194 lesions) were randomized in a 2:1 ratio for treatment with SES or BES, respectively. The primary endpoint for the present study was the five-year rate of combined major adverse cardiac events, defined as cardiac death, myocardial infarction, or target lesion revascularization. RESULTS: At five years, the primary endpoint occurred in 12.5% and 17.9% of the SES and BES groups, respectively (p=0.4). There was no definite or probable stent thrombosis among patients treated with the novel SES stent during the five years of follow-up, and no stent thrombosis after the first year in the BES group. CONCLUSIONS: The novel Inspiron™ stent had similar good clinical performance in long-term follow-up when compared head-to-head with the control latest-generation Biomatrix™ Flex biolimus-eluting stent.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Polímeros , Diseño de Prótesis , Resultado del Tratamiento
15.
Circ Cardiovasc Interv ; 12(6): e007283, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31177821

RESUMEN

Background A novel bioresorbable scaffold, the sirolimus-eluting Fantom, incorporates a radiopaque polymer, struts with a thickness of 125 µm, and a crossing profile of 1.35 mm. The purpose of this study was to evaluate the 9-month angiographic and 12-month clinical outcomes of the FANTOM scaffold in a larger patient population. Methods and Results The FANTOM II study (Safety & Performance Study of the Fantom Sirolimus-Eluting Bioresorbable Coronary Scaffold - First Report on Initial 24 Month Outcomes) was a prospective, multicenter trial which enrolled 240 patients with single de novo coronary stenosis with reference vessel diameter 2.5 to 3.5 mm diameter and lesion length ≤20 mm. Major adverse cardiac events through 12-month follow-up were assessed. Angiographic follow-up was performed in consecutive patient cohorts at 6 months (n=117) and 9 months (n=123). Acute delivery success, acute technical success, acute procedural success, and clinical procedural success rates as defined in the clinical protocol were 97.9% (235/240), 95.8% (230/240), 99.1% (228/230), and 99.6% (227/228), respectively. The mean in-stent late lumen loss at 6 months and 9 months were 0.25±0.40 mm and 0.33±0.36 mm, respectively, and in-segment binary restenosis occurred in 2.0% and 7.6% of patients, respectively. Major adverse cardiac events and target lesion failure through 12 months occurred in 4.2% of 240 patients; scaffold thrombosis developed in only one patient (0.4%). Conclusions The Fantom sirolimus-eluting bioresorbable coronary scaffold demonstrated favorable safety and effectiveness performance at 12-month follow-up. Longer-term follow-up is ongoing to examine the late outcomes with this novel device. Clinical Trial Registration URL: https://www.clinicaltrials.gov . Unique identifier: NCT02539966.


Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Angiografía Coronaria , Estenosis Coronaria/terapia , Sirolimus/administración & dosificación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Estenosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
16.
EuroIntervention ; 14(18): e1836-e1842, 2019 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-29957593

RESUMEN

AIMS: The MASTER study was designed to compare the performance of a new biodegradable polymer sirolimus-eluting stent (BP-SES) with a bare metal stent (BMS) in patients with ST-segment elevation myocardial infarction (STEMI). METHODS AND RESULTS: The study was a prospective, randomised (3:1), controlled, single-blind multicentre trial that enrolled 500 STEMI patients within 24 hours of symptom onset during 2013-2015. Three hundred and seventy-five patients were treated with BP-SES and 125 with BMS. One hundred and four (104) randomised patients underwent angiographic follow-up at six months. The primary clinical endpoint was target vessel failure (TVF), defined as cardiac death, MI not clearly attributable to a non-target vessel, or clinically driven target vessel revascularisation (TVR) at 12 months. The primary angiographic endpoint was in-stent late lumen loss (LLL) at six months in the angiographic cohort. The major secondary endpoint for safety was a composite of all-cause death, recurrent MI, unplanned infarct-related artery revascularisation, stroke, definite stent thrombosis (ST) or major bleeding at one month. At 12 months, TVF had occurred in 6.1% of BP-SES and 14.4% of BMS patients (pnon-inferiority=0.0004), mainly driven by a higher rate of repeat revascularisation in BMS patients. The safety endpoint occurred in 3.5% of BP-SES and 7.2% of BMS patients (p=0.127). In-stent LLL demonstrated the superiority (p=0.0125) of BP-SES (0.09±0.43 mm) over BMS (0.79±0.67 mm). CONCLUSIONS: The study showed clinical non-inferiority and angiographic superiority of BP-SES versus a comparator BMS, suggesting that this novel DES may be a potential treatment option in STEMI.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio con Elevación del ST , Humanos , Polímeros , Estudios Prospectivos , Infarto del Miocardio con Elevación del ST/cirugía , Método Simple Ciego , Sirolimus , Resultado del Tratamiento
17.
EuroIntervention ; 14(11): e1207-e1214, 2018 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-30222120

RESUMEN

AIMS: The aim of this study was to evaluate the safety and efficacy of the BioMime sirolimus-eluting coronary stent (SES) compared to the XIENCE family of everolimus-eluting coronary stents (EES) in the treatment of patients with de novo native coronary artery lesions. METHODS AND RESULTS: The meriT-V is a prospective, multicentre, randomised, open-label, active-controlled, non-inferiority trial. A total of 256 patients with up to two de novo native coronary artery lesions were enrolled and randomly assigned (2:1) to BioMime SES or XIENCE EES. BioMime SES was non-inferior to XIENCE EES for the primary endpoint of in-stent late lumen loss (0.15±0.27 mm vs. 0.15±0.29 mm; difference: -0.006 mm; 95% confidence interval: -0.085 to 0.072; p=0.87; p for non-inferiority <0.0001) at nine-month follow-up. The major adverse cardiac events rate was numerically lower in the BioMime SES group (2.98% vs. 7.14%; p=0.13), driven by a statistically significant lower risk of any myocardial infarction (0.60% vs. 4.76%; p=0.03), when compared with the XIENCE EES group. There was no difference in target vessel myocardial infarction (p=0.62) between the groups. There was no definite or probable stent thrombosis in either group. CONCLUSIONS: In the treatment of de novo native coronary artery lesions, the biodegradable polymer ultra-thin SES (BioMime) was non-inferior to a durable polymer EES (XIENCE) at nine-month follow-up. Further studies powered for clinical endpoints are needed.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Everolimus , Humanos , Polímeros , Estudios Prospectivos , Sirolimus , Resultado del Tratamiento
18.
Vasc Health Risk Manag ; 3(2): 191-201, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17580729

RESUMEN

The sirolimus-eluting coronary stent received CE Mark approval in Europe in April 2002. In the US, FDA approval followed in April 2003. Since the preliminary results from the First-in-Man feasibility study were presented, several randomized, controlled trials have documented the profound antiproliferative effects of sirolimus, a macrolide antibiotic and potent cytostatic inhibitor of smooth muscle cell proliferation. Subsequently, the body of clinical evidence was increased by the second wave of evidence from trials in more complex lesions (such as in-stent restenosis, small vessels, chronic total occlusions) and "high-risk" patients such as those with diabetes. More recently we have had the opportunity to compare the two commercially available drug-eluting stents following the presentation of data from six head-to-head trials. As a result of numerous single and multi-center, national and international studies in which the safety and efficacy of sirolimus-eluting coronary stents have been subjected to close scrutiny, the global interventional cardiology community now has a wealth of evidence in support of the use of this technology resulting in dramatically improved patient outcomes after percutaneous intervention.


Asunto(s)
Implantación de Prótesis Vascular/instrumentación , Materiales Biocompatibles Revestidos , Reestenosis Coronaria/prevención & control , Inmunosupresores/farmacología , Sirolimus/farmacología , Stents , Ensayos Clínicos como Asunto , Humanos , Factores de Riesgo , Resultado del Tratamiento
19.
Int J Cardiovasc Imaging ; 33(2): 161-168, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27714601

RESUMEN

We sought to compare, by means of IVUS and OCT imaging, the performance of a novel sirolimus-eluting drug-eluting stent (DES) with biodegradable polymer (Inspiron™) to the Biomatrix™ DES. From the DESTINY trial, a total of 70 randomized patients (2:1) were enrolled in the IVUS substudy (Inspiron™, n = 46; Biomatrix™: n = 20) while 25 patients were evaluated with OCT (Inspiron™, n = 19; Biomatrix™: n = 06) at 9-month follow-up. The main endpoints were % of neointimal tissue obstruction (IVUS) and neointimal stut coverage (OCT) at 9 months. Patients treated with both DES had very little NIH formation at 9 months either by IVUS (% of NIH obstruction of 4.9 ± 4.1 % with Inspiron™ vs. 2.7 ± 2.9 % with Biomatrix™, p = 0.03) or by OCT (neointimal thickness of 144.2 ± 72.5 µm Inspiron™ vs. 115.0 ± 53.9 µm with Biomatrix™, p = 0.45). Regarding OCT strut-level assessment, again both devices showed excellent 9-month performance, with high rates of strut coverage (99.49 ± 1.01 % with Inspiron™ vs. 97.62 ± 2.21 % with Biomatrix™, p < 0.001) and very rare malapposition (0.29 ± 1.06 % with Inspiron™ vs. 0.53 ± 0.82 % with Biomatrix™, p = 0.44). Patients with any uncovered struts were more frequently identified in the Biomatrix™ group (9.78 ± 7.13 vs. 2.29 ± 3.91 %, p < 0.001). In the present study, midterm IVUS and OCT evaluations showed that both new generation DES with biodegradable polymer were effective in terms of suppressing excessive neointimal response, with very high rates of apposed and covered struts, suggesting a consistent and benign healing pattern.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/efectos de los fármacos , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Metales , Intervención Coronaria Percutánea/instrumentación , Polímeros/química , Sirolimus/análogos & derivados , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional , Fármacos Cardiovasculares/efectos adversos , Humanos , Neointima , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Diseño de Prótesis , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
20.
JACC Cardiovasc Interv ; 10(18): 1832-1838, 2017 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-28935075

RESUMEN

OBJECTIVES: The purpose of this study was to evaluate the outcomes of the novel Fantom coronary bioresorbable scaffold at 6 months. BACKGROUND: The Fantom sirolimus-eluting bioresorbable scaffold incorporates a unique proprietary iodinated, polycarbonate copolymer of tyrosine analogs that is radiopaque, with thin struts (125 µm) that facilitate device delivery and precise target lesion treatment. METHODS: The 6-month outcomes and performance of the Fantom scaffold were evaluated in 117 patients with single de novo native coronary artery lesions of length ≤20 mm and reference vessel diameter 2.5 to 3.5 mm. The primary angiographic endpoint was mean late lumen loss at 6 months measured by quantitative coronary angiography. Procedural outcomes were categorized as short-term technical success, short-term procedural success, and clinical procedural success. The primary clinical endpoint was major adverse cardiac events at 6 months, the composite of cardiac death, myocardial infarction (MI), or clinically driven target lesion revascularization (TLR). RESULTS: Short-term technical success, short-term procedural success, and clinical procedural success were achieved in 96.6%, 99.1%, and 99.1% of patients, respectively. Mean 6-month in-stent late lumen loss was 0.25 ± 0.40 mm (n = 100). Binary restenosis was present in 2 patients (2.0%). Major adverse cardiac events within 6 months occurred in 3 patients (2.6%), including no deaths, 2 MIs, and 2 TLRs (1 patient had both an MI and TLR). Scaffold thrombosis occurred in 1 patient (0.9%). CONCLUSIONS: The clinical results from 117 patients enrolled in cohort A of the multicenter FANTOM II (Safety & Performance Study of the FANTOM Sirolimus-Eluting Bioresorbable Coronary Scaffold) study demonstrate favorable 6-month outcomes of this novel device in the treatment of noncomplex coronary artery disease.


Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Sirolimus/administración & dosificación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/etiología , Valor Predictivo de las Pruebas , Diseño de Prótesis , Factores de Riesgo , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA