1.
J Periodontal Res ; 56(2): 415-422, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33368278

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the sterilization effectiveness against biofilms on retrieved healing abutments used in implant dentistry. BACKGROUND: A large number of clinicians reuse healing abutments to decrease treatment costs although it can promote infection due to the presence of remnant biofilm biomass. METHODS: One hundred and eighty-five titanium healing abutments previously used for 3 months in oral cavity were assessed in this study. Abutments were submitted to cleaning, chemical disinfection, and autoclave sterilization according to clinical guidelines. The abutments were aseptically placed into glass tubes containing specific bacterial growth medium and then incubated for 10 days. From glass tubes with bacterial growth, 100 µl medium was transferred to Schaedler's agar for morphological identification and counting of strict anaerobes and to Columbia blood agar for presumptive identification of facultative anaerobes after incubation. Isolated strains were then identified at species level by enzymatic and biochemical tests within API microorganism detection platform. Also, polymerase chain reaction (PCR) was performed for identification of undefined strains. RESULTS: After the standard cleaning and sterilization procedures, fifty-six (approximately 30%) retrieved abutments showed the presence of remnant biofilm biomass. The bacteria identified into the remnant biofilms covering the abutments were representative of the commensal oral microbiota including Aggregatibacter actinomycetemcomitans, Prevotella intermedia, and Enterococcus faecalis. CONCLUSION: Although some healing abutments did not reveal the existence of bacteria, organic components from biofilm biomass are still strongly adhered on the retentive micro-regions and surfaces of abutments and therefore that would support the accumulation of biofilm including pathogenic species leading to patients' cross-infections. Further studies should be performed on the assessment of different materials, design, and connections of the healing abutments associated with clinical disinfection procedures in implant dentistry.


Asunto(s)
Pilares Dentales , Implantes Dentales , Biopelículas , Humanos , Esterilización , Propiedades de Superficie , Titanio
2.
Biomedicines ; 11(6)2023 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-37371776

RESUMEN

Dental-implant-supported reconstructions provide comfort and improvements in prosthetic function, adaptation, and stability over conventional treatment options. The objective of this study was to evaluate the effect of different denture cleansing solutions and their influence on the deterioration and loss of retention of overdenture attachments in a 12-month clinical-use simulation. In this way, ten specimens each of different brands of retentive caps made of Teflon (OT Equator® (Rhein83, Bologna, Italy), Locator® (Zest Anchors, Escondido, CA, USA), Kerator® (KJ Meditech, Gwangiu, Republic of Korea), and Locator R-Tx® (Zest Anchors, Escondido, CA, USA)) were immersed in five different cleaning solutions (Kukident® (P&G Tech, Oxford Parkway, UK), Benfix® (Laboratorios URGO S.L., Guipúzcoa, Spain), Corega® (Stafford Miller, Waterford, Ireland), and Protefix® (Neuhofer Weiche, Parchim, Germany)), and tap water was used as the control group, in a simulation that lasted 12 months. Data were analyzed using two-way ANOVA and a Tukey HSD. Furthermore, a Levene Test and Shapiro-Wilk tests were performed to assess the validation of the ANOVA assumptions. The statistical analysis was performed using R version 4.2.2 software with the significance level set to p < 0.05. There were significant statistical differences between the different manufacturers regarding the retention forces of the attachment's retentive caps (F = 322.066, p < 0.001). For the cleaning solution groups, different statistical results between Kukident® (P&G Tech, Oxford Parkway, UK) (p < 0.05) and Benfix® (Laboratorios URGO S.L., Guipúzcoa, Spain) (p < 0.05) were observed. There were no significant statistical differences between Corega® (Stafford Miller, Ireland), Protefix® (Neuhofer Weiche, Parchim, Germany), and tap water, even though the retention forces decreased in all of them.

3.
Polymers (Basel) ; 14(9)2022 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-35566919

RESUMEN

(1) Introduction: Denture adhesives (DAs) promote stability, chewing ability, and quality of life. The objective of this study was to compare the effectiveness of original brand DAs and white brands in their retention of conventional complete dentures. (2) Methods: This study followed the recommendations of the international standard ISO 10873. Three original brands of DA (Corega® Fixação 3D, GlaxoSmithKline®, Stafford Miller Ltd., Dungarvan Co. Waterford, Ireland), KuKident® Pro Procter & Gamble Technical Centres®, Ltd., Whitehal Lane, Germany and Elgydium® Fix, Laboratórios URGO® SL, Florida, Spain) were compared to three white brands (Fixação Extra Forte Pingo Doce®, Laboratórios Cosmodent®, Cantabria, Spain), Fixador de Próteses (Continente®, Propack®,Gmbh, Ladenburg, Germany) and Creme Fixador de Próteses (Auchan®, Ellipse®, Roubaix, France). Their retention capacities were analyzed using a mechanical test device. (3) Results: The mean retentive ability of original brand adhesives (M = 11.16, SD = 5.27) was significantly higher (t(298) = 11.88; p < 0.001) than that of the white brands (M = 5.92, SD = 1.18). When comparing all brands, statistically significant differences were also observed, F(5.294) = 707.68 (p < 0.001). The generic adhesive results were more homogeneous. The generic brands from Continente® (M = 5.24, SD = 0.94) and Auchan® (M = 5.80, SD = 0.79) were not significantly different, while the Pingo Doce® brand obtained significantly higher mean retention results (M = 6.71, SD = 1.28). (4) Conclusions: The original brands of DA have a significantly higher retentive ability than the white brands. Elygidim® Fix had the worst result of the three original brands, and the product from Pingo Doce® had the best result among the three white brands.

4.
Dent J (Basel) ; 10(6)2022 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-35735654

RESUMEN

With continuing technological developments, there have been advances in the field of fixed prosthetics, particularly in impression-taking techniques. These technological advances mean that a wide variety of diagnostic and/or rehabilitation possibilities can be explored without the need for physical models. The aim of this study was to evaluate the accuracy of three intraoral scanners used in oral implant rehabilitation using an extraoral scanner as a reference and varying the scanning area. Three models representing different clinical scenarios were scanned 15 times by each intraoral scanner and three times by the extraoral scanner. The readings were analyzed and overlaid using engineering software (Geomagic® Control X software (Artec Europe, Luxembourg)). Statistically significant differences in accuracy were found between the three intraoral scanners, iTero® (Align Technology Inc., San Jose, CA, USA), Medit® (Medit®: Seoul, Korea), and Planmeca® (Planmeca®: Helsinki, Finland). In all clinical scenarios, the iTero® scanner had the best trueness (24.4 µm), followed by the Medit® (26.4 µm) and Planmeca® (42.1 µm). The Medit® showed the best precision (18.00 µm) followed by the iTero® (19.20 µm) and Planmeca® (34.30 µm). We concluded that the iTero® scanner had the highest reproducibility and accuracy in the clinical setting.

5.
Materials (Basel) ; 15(19)2022 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-36233980

RESUMEN

(1) Introduction: Implant-supported fixed complete dentures are mostly composed of cantilevers. The purpose of this work was to evaluate the fracture resistance of zirconia (Prettau®, second generation, or Ice Zirkon Translucent, first generation) with cantilever lengths of 6 and 10 mm, and zirconia's fracture resistance in relation to an average bite force of 250 N. (2) Materials and methods: Forty structures were created in CAD/CAM and divided into four groups: group A (6 mm cantilever in IZT), group B (10 mm cantilever in IZT), group C (6 mm cantilever in Pz), and group D (10 mm cantilever in pz). The study consisted of a traditional "load-to-failure" test. (3) Results: A statistically significant result was found for the effect of cantilever length, t(38) = 16.23 (p < 0.001), with this having a large effect size, d = 4.68. The 6 mm cantilever length (M = 442.30, sd = 47.49) was associated with a higher mean force at break than the 10 mm length (M = 215.18, sd = 40.74). No significant effect was found for the type of zirconia: t(38) = 0.31 (p = 0.757), and d = 0.10. (4) Conclusions: All the components with cantilever lengths of 6 mm broke under forces higher than 250 N. Cantilevers larger than 10 mm should be avoided.

6.
Int J Dent ; 2021: 5133556, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34899914

RESUMEN

Micromovements of the implant-abutment connection influence peri-implant bone preservation. The maximal torque after a cycle of implant prosthetic screw tightening using original components of different manufacturers and replicas produced by other companies is evaluated and quantified in this study. A total of 30 Mis Seven® standard platform implants and 30 interfaces were used, and 30 standard platform screws were tested, 10 Mis®, 10 Iconekt®, and 10 Exaktus®. The screws were tightened with an MIS® torquemeter until their respective fracture, and the fracture point was measured through the equipment's load cell, CS-Dental Testing Machine®. The screws were analyzed under an Olympus® SZ61 microscope. The fracture points were recorded and compared among all samples. To compare the mean values of the fracture torques, t-tests were performed using the reference values associated with each brand and the sample results. The variable "Place of Fracture" between the original Mis® brand and the Exaktus® replica compared to the Iconekt® replica presented a statistically significant difference (p < 0.001). When analyzing the variable "Fracture Torque," although it was verified that the replica screws (Iconekt® and Exaktus®) had a lower maximum torque, 65.11 Nm and 62.89 Nm, respectively, compared to the original Mis® brand (70 Nm and 69 Nm), there were no statistically significant differences p > 0.05. Nonoriginal screws did not present different fracture resistances compared to the original Mis® brand screws. The fracture site of Iconekt® screws showed a different pattern compared to the other brands.

7.
Polymers (Basel) ; 13(8)2021 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-33920377

RESUMEN

Thermal and self-curing acrylic resins are frequently and versatilely used in dental medicine since they are biocompatible, have no flavor or odor, have satisfactory thermal qualities and polishing capacity, and are easy and fast. Thus, given their widespread use, their fracture resistance behavior is especially important. In this research work, we comparatively analyzed the fracture resistance capacity of thermo and self-curing acrylic resins in vitro. Materials and Methods: Five prosthesis bases were created for each of the following acrylic resins: Lucitone®, ProBase®, and Megacryl®, which were submitted to different forces through the use of the CS® Dental Testing Machine, usually mobilized in the context of fatigue tests. To this end, a point was defined in the center of the anterior edge of the aforementioned acrylic resin bases, for which the peak tended until a fracture occurred. Thermosetting resins were, on average, more resistant to fracture than self-curable resins, although the difference was not statistically significant. The thermosetting resins of the Lucitone® and Probase® brands demonstrated behavior that was more resistant to fracture than the self-curing homologues, although the difference was not statistically significant. Thermosetting resins tended to be, on average, more resistant to fracture and exhibited the maximum values for impact strength, compressive strength, tensile strength, hardness, and dimensional accuracy than self-curing resins, regardless of brand.