Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Dent Traumatol ; 37(5): 725-731, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33638228

RESUMEN

Traumatic dental injuries in elderly patients are a rising trend due to demographic and social changes of the population. Older dentulous patients in good health have become increasingly common. The development of a post-traumatic malocclusion is a common sequela resulting from mandibular condyle fracture, as in the case reported in this paper. The decision-making process led the authors to rule out conservative treatment options and to perform orthognathic surgery on an 81-year-old patient, an unprecedented report in the literature. At one-year follow-up, prophylactic therapy, a specific surgical technique, and osteotomy fixation have restored the occlusion to the pre-traumatic condition.


Asunto(s)
Maloclusión , Fracturas Mandibulares , Anciano , Anciano de 80 o más Años , Oclusión Dental , Humanos , Maloclusión/etiología , Mandíbula , Cóndilo Mandibular , Fracturas Mandibulares/diagnóstico por imagen , Fracturas Mandibulares/cirugía , Osteotomía
2.
BMC Oral Health ; 21(1): 100, 2021 03 06.
Artículo en Inglés | MEDLINE | ID: mdl-33676469

RESUMEN

BACKGROUND: To introduce a theoretical solution to a posteriori describe the pose of a cylindrical dental fixture as appearing on radiographs; to experimentally validate the method described. METHODS: The pose of a conventional dental implant was described by a triplet of angles (phi-pitch, theta-roll, and psi-yaw) which was calculated throughout vector analysis. Radiographic- and simulated-image obtained with an algorithm were compared to test effectiveness, reproducibility, and accuracy of the method. The length of the dental implant as appearing on the simulated image was calculated by the trigonometric function and then compared with real length as it appeared on a two-dimensional radiograph. RESULTS: Twenty radiographs were analyzed for the present in silico and retrospective study. Among 40 fittings, 37 resulted as resolved with residuals ≤ 1 mm. Similar results were obtained for radiographic and simulated implants with absolute errors of - 1.1° ± 3.9° for phi; - 0.9° ± 4.1° for theta; 0° ± 1.1° for psi. The real and simulated length of the implants appeared to be heavily correlated. Linear dependence was verified by the results of the robust linear regression: 0.9757 (slope), + 0.1344 mm (intercept), and an adjusted coefficient of determination of 0.9054. CONCLUSIONS: The method allowed clinicians to calculate, a posteriori, a single real triplet of angles (phi, theta, psi) by analyzing a two-dimensional radiograph and to identify cases where standardization of repeated intraoral radiographies was not achieved. The a posteriori standardization of two-dimensional radiographs could allowed the clinicians to minimize the patient's exposure to ionizing radiations for the measurement of marginal bone levels around dental implants.


Asunto(s)
Implantes Dentales , Humanos , Imagenología Tridimensional , Radiografía , Estándares de Referencia , Reproducibilidad de los Resultados , Estudios Retrospectivos
3.
J Craniofac Surg ; 29(8): 2131-2134, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29944551

RESUMEN

PURPOSE: To investigate morbidity related to harversting of bilateral fibula free flap for head and neck reconstruction using subjective and functional tests. METHODS: Patients were retrospectively evaluated using point evaluation system (PES) and balance evaluation systems test (BESTest) questionnaires to assess morbidity related to surgery. RESULTS: Five patients were enrolled in the study. Mean PES scores was 22.2 over 24. Mean overall function assessed with BESTest was 77.6%, and the results were poorest for section I. Sections V and VI had scores of 88% and 83%, respectively, indicating that the sensory balance and gait stability of the patients were compromised only minimally. CONCLUSION: Bilateral harvesting of the fibula free flap is not associated with an increase in long-term morbidity and does not lead to significant functional impairments. Therefore, this procedure should be considered safe, and can be performed without concern regarding morbidity, when bone reconstruction with a fibula free flap is indicated.


Asunto(s)
Peroné/cirugía , Colgajos Tisulares Libres/efectos adversos , Reconstrucción Mandibular/efectos adversos , Complicaciones Posoperatorias/etiología , Recolección de Tejidos y Órganos/efectos adversos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Morbilidad , Estudios Retrospectivos , Sitio Donante de Trasplante , Adulto Joven
4.
J Craniofac Surg ; 26(1): e44-8, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25569412

RESUMEN

The purpose of this study was to analyze a case of mandibular distraction in a case of Treacher Collins syndrome. Mandibular distraction is an adequate surgical treatment of patients with Pierre Robin sequence and represents an alternative to tracheostomy. In severe hypoplastic cases or when three-dimensional vector control or gonial angle control is necessary, extraoral bidirectional or multidirectional devices have an advantage over intraoral devices. The anchorage obtained with transfixing Kirschner wires fixed in the mandibular distal segment and symphysis is crucial in neonates for the stability of the devices. Moreover, with the use of a second pin for each bone segment, the extraoral devices allow to modify the vector orientation and consequently the shape of the newly formed mandible.


Asunto(s)
Mandíbula/cirugía , Disostosis Mandibulofacial/cirugía , Osteogénesis por Distracción/métodos , Clavos Ortopédicos , Hilos Ortopédicos , Diseño de Equipo , Fijadores Externos , Estudios de Seguimiento , Humanos , Recién Nacido , Masculino , Mandíbula/anomalías , Avance Mandibular/métodos , Cóndilo Mandibular/anomalías , Cóndilo Mandibular/cirugía , Reconstrucción Mandibular/métodos , Osteogénesis/fisiología , Osteogénesis por Distracción/instrumentación
5.
Int J Periodontics Restorative Dent ; 43(4): e165-e172, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37552194

RESUMEN

Adequate implant primary stability is a key factor to obtain osseointegration and can be measured at insertion by insertion torque (IT) and at different timepoints with resonance frequency analysis (RFA), expressed as an implant stability quotient (ISQ). This retrospective study investigated the correlation between ISQ and IT at implant insertion. All patients who were eligible for this single-cohort retrospective clinical trial were treated with an immediate implant. IT parameters were recorded at implant insertion, and ISQ values were recorded at insertion and at 2-, 4-, and 12-month follow-ups. The study comprised 23 patients who received 32 implants. The mean IT value was 46.87 ± 9.66 Ncm (range: 25 to 65 Ncm), and the mean ISQ value at implant insertion was 71.45 ± 4.24 (range: 63 to 78); these values showed a statistically significant correlation (P < .0001). According to the present data and considering the implant design used in this trial, there is a statistically significant and positive correlation between IT and ISQ values. Thus, ISQ can be used as a reliable method to measure implant stability over time.


Asunto(s)
Implantación Dental Endoósea , Implantes Dentales , Humanos , Implantación Dental Endoósea/métodos , Retención de Prótesis Dentales , Oseointegración , Análisis de Frecuencia de Resonancia , Estudios Retrospectivos , Torque
6.
J Stomatol Oral Maxillofac Surg ; 124(6S): 101500, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37187242

RESUMEN

INTRODUCTION: The present study aimed to examine the middle-term effects of transcrestal double-sinus elevation (TSFE) versus alveolar/palatal split expansion technique (APS) and simultaneous implant placement in the augmented sinus. NULL HYPOTHESIS: there were no differences between groups. MATERIAL & METHODS: Magnetoelectric device was used for bone augmentation and expansion techniques in long-standing edentulous patients with a deficiency in vertical height in the posterior maxilla (3mm to 4mm residual bone height): TSFE group, or two-stage process with a first transcrestal sinus floor augmentation and a second sinus floor elevation with immediate implant placement; APS group, or "dual split and dislocation" of the two cortical bony plates towards the sinus and palatal side. Volumetric and linear analyses were performed on the superimposed preoperative and postoperative 3-year computed tomography scans. The level of significance was set at 0.05. RESULTS: Thirty patients were selected for the present analysis. For both groups significant differences were found in the volume outcomes between baseline and 3-year follow-up, showing a gain of about +0.28±0.06cm3 for the TSFE group, and +0.43±0.12cm3 for the APS group, with p-values < 0.0001. However, an effective increase of the volume of the alveolar crest was registered just in the APS group (+0.22±0.09cm3). A significant increase in bone width was found in the APS group (+1.45±0.56mm with p-value < 0.0001); on the contrary, a slight width reduction of the alveolar crest was observed in the TSFE group (-0.63±0.21mm). DISCUSSION: TSFE procedure seemed to not affect the shape of the alveolar crest. APS procedures led to a higher increase of the volume available for dental implant placement and could be used in horizontal bone defects too.


Asunto(s)
Implantes Dentales , Elevación del Piso del Seno Maxilar , Humanos , Implantación Dental Endoósea/métodos , Elevación del Piso del Seno Maxilar/métodos , Estudios Retrospectivos , Seno Maxilar/diagnóstico por imagen , Seno Maxilar/cirugía , Proceso Alveolar/diagnóstico por imagen , Proceso Alveolar/cirugía
7.
Int J Oral Maxillofac Implants ; 37(5): 920-928, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36170306

RESUMEN

PURPOSE: To examine the short-term outcomes of maxillary sinus augmentations consisting of laterally and apically displacing the palatal wall through a transcrestal approach. MATERIALS AND METHODS: The maxillary sinus floor was fractured in its palatal aspect by allowing a displacement in the buccal and apical direction with a magnetoelectric system. A medial displacement of the alveolar crest in its palatal bony plate was performed at the same time. Crestal bone change was investigated using superimposed preoperative and postsurgical computed tomography scans. Clinical and radiologic outcomes over 1 year were evaluated. RESULTS: A total of 18 implants were selected for retrospective volumetric and linear analyses. Sinus floor and alveolar bone augmentation surgery led to a significant increase in the bone volume (P = .0002) from 0.134 ± 0.060 cm3 to 0.639 ± 0.166 cm3, with an overall gain of +0.504 ± 0.139 cm3. No part of the implant apices appeared to protrude into the maxillary sinus at the 1-year follow-up. The width of the alveolar crest changed from 5.1 ± 0.5 mm to 6.5 ± 0.7 mm, with a significant increase of +1.4 ± 0.6 mm registered at 1 year. However, a marginal bone loss of 1.0 ± 0.8 mm was observed. When tooth positions were investigated, no significant differences between the two groups (premolars versus molars) were found. CONCLUSION: Significant and effective bone gains allowed proper placement of the dental implants but with a minimal loss of peri-implant bone volume.


Asunto(s)
Implantes Dentales , Elevación del Piso del Seno Maxilar , Implantación Dental Endoósea/métodos , Maxilar/cirugía , Seno Maxilar/diagnóstico por imagen , Seno Maxilar/cirugía , Estudios Retrospectivos , Elevación del Piso del Seno Maxilar/métodos , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA