Liver Int ; 31(1): 66-74, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20840397

RESUMEN

OBJECTIVES: To investigate the independent association between the homeostasis model assessment of the insulin resistance (HOMA-IR) score and rapid virological response (RVR) and sustained virological response (SVR) in chronic hepatitis C (CHC). METHODS: Observational prospective cohort study of 412 CHC patients [59% males; mean age 45 years; genotype 1 (44%), 2 (32%), 3 (19%) and 4 (5%)] treated with pegylated interferon α plus ribavirin. RESULTS: A HOMA-IR ≥2.0 was present in 49% and a metabolic syndrome in 4% of patients. By multivariate analysis, independent predictors of SVR were the lack of advanced fibrosis (≥F3) in genotype 1 and a lower body mass index in genotype 3 patients. In the subgroup of patients in whom HCV-RNA was evaluated at week 4 (n = 281), independent predictors of RVR were HCV-RNA <700,000 IU/ml, age <40 years and lower aspartate aminotransferase:alanine aminotransferase ratio in genotype 1 and baseline HOMA-IR ≤2 in genotype 3 patients. No predictive factor of RVR was identified among genotype 2 patients. RVR was the strongest predictor of SVR among genotype 1 or 3 patients. CONCLUSIONS: In this series of treatment-naïve, Caucasian CHC patients at a low risk for the metabolic syndrome, HOMA-IR is not a predictor of SVR, irrespective of the HCV genotype, although it may predict RVR in genotype 3 infection.


Asunto(s)
Antivirales/uso terapéutico , Indicadores de Salud , Hepacivirus/efectos de los fármacos , Hepatitis C Crónica/tratamiento farmacológico , Resistencia a la Insulina , Interferón-alfa/uso terapéutico , Polietilenglicoles/uso terapéutico , Ribavirina/uso terapéutico , Adulto , Distribución de Chi-Cuadrado , Quimioterapia Combinada , Femenino , Genotipo , Hepacivirus/genética , Hepatitis C Crónica/diagnóstico , Hepatitis C Crónica/etnología , Hepatitis C Crónica/fisiopatología , Humanos , Interferón alfa-2 , Italia , Modelos Logísticos , Masculino , Persona de Mediana Edad , Modelos Biológicos , Valor Predictivo de las Pruebas , Estudios Prospectivos , ARN Viral/sangre , Proteínas Recombinantes , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Carga Viral , Población Blanca
2.
Clin Chem Lab Med ; 43(3): 319-25, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15843239

RESUMEN

The predominant technique used to draw blood for laboratory testing is a conventional straight needle attached to an evacuated tube system. However, alternative tools might be advantageous in exceptional circumstances. The use of butterfly devices has been traditionally discouraged for reasons of costs and due to the high risk of obtaining unsuitable samples, but there is no convincing evidence to support the latter indication. The purpose of this study was to compare results of hematological and clinical chemistry testing, after drawing blood into evacuated tubes, employing either a traditional 21-gauge straight needle or a 21-gauge butterfly device with 300-mm-grade polyvinyl chloride tubing. Blood samples and complete sets of data were successfully obtained for 30 consecutive outpatients. Of the 43 hematological and clinical chemistry parameters measured, means for paired samples collected by the two alternative drawing techniques did not differ significantly, except for serum sodium, white blood cells and platelets counts. Bland-Altman plots and limits-of-agreement analysis showed mean bias of between -7.2% and 1.7% and relative coefficients of variation ranging from 0.2% to 21.2%. The 95% agreement interval in the set of differences was acceptable and was mostly within the current analytical quality specifications for desirable bias. The rate of hemolysis in plasma was not statistically different between the two collection techniques. Taken together, the results of the present investigation suggest that, when a proper technique is used and within certain limitations, the butterfly device may be a reliable alternative to the conventional straight needle to draw blood for laboratory testing.


Asunto(s)
Recolección de Muestras de Sangre/métodos , Pruebas de Química Clínica/métodos , Técnicas de Laboratorio Clínico/métodos , Femenino , Hemólisis , Humanos , Masculino , Persona de Mediana Edad , Agujas , Cloruro de Polivinilo