Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Acta Orthop ; 91(6): 782-788, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32691656

RESUMEN

Background and purpose - Biological patches can be used to augment rotator cuff tendon repair in an attempt to improve healing and reduce rates of re-rupture. However, little is known about the in vivo tissue response to these patches. We assessed native rotator cuff tissue response after surgical repair and augmentation with 2 commercially available extracellular matrix (ECM) patches. Patients and methods - Patients underwent a rotator cuff repair augmented with either GraftJacket (Wright Medical), Permacol (Zimmer Biomet), or no patch (Control), applied using an onlay technique. A sample of supraspinatus tendon was collected intraoperatively and 4 weeks post-surgery, using ultrasound-guided biopsy. Histology and immunohistochemistry were performed on all samples. Results - The Permacol group (n = 3) and GraftJacket group (n = 4) demonstrated some changes in native tendon ECM compared with the control group (n = 3). Significant disruption of the extracellular matrix of the repaired native supraspinatus, underlying both patches, was observed. The patches did not generally increase cellularity, foreign body giant cell count, or vascularity compared to the control group. 1 patient in the Permacol group had an adverse tissue immune response characterized by extensive infiltration of IRF5+, CD68+, and CD206+ cells, suggesting involvement of macrophages with a pro-inflammatory phenotype. No significant differences in protein expression of CD4, CD45, CD68, CD206, BMP7, IRF5, TGFß, and PDPN were observed among the groups. Interpretation - Histological and immunohistochemical analysis of native tendon tissue after patch augmentation in rotator cuff repair raises some concerns about a lack of benefit and potential for harm from these materials.


Asunto(s)
Artroplastia , Colágeno , Biopsia Guiada por Imagen/métodos , Inflamación , Ensayo de Materiales/métodos , Lesiones del Manguito de los Rotadores/cirugía , Manguito de los Rotadores , Artroplastia/efectos adversos , Artroplastia/instrumentación , Artroplastia/métodos , Materiales Biocompatibles/efectos adversos , Materiales Biocompatibles/uso terapéutico , Colágeno/efectos adversos , Colágeno/uso terapéutico , Femenino , Reacción a Cuerpo Extraño/etiología , Reacción a Cuerpo Extraño/inmunología , Reacción a Cuerpo Extraño/patología , Humanos , Inflamación/etiología , Inflamación/inmunología , Inflamación/patología , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , Manguito de los Rotadores/irrigación sanguínea , Manguito de los Rotadores/inmunología , Ultrasonografía/métodos , Reino Unido , Cicatrización de Heridas/inmunología
2.
J Cell Physiol ; 231(1): 36-49, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26058815

RESUMEN

Globally health care spending is increasing unsustainably. This is especially true of the treatment of musculoskeletal (MSK) disease where in the United States the MSK disease burden has doubled over the last 15 years. With an aging and increasingly obese population, the surge in MSK related spending is only set to worsen. Despite increased funding, research and attention to this pressing health need, little progress has been made toward novel therapies. Tissue engineering and regenerative medicine (TERM) strategies could provide the solutions required to mitigate this mounting burden. Biomaterial-based treatments in particular present a promising field of potentially cost-effective therapies. However, the translation of a scientific development to a successful treatment is fraught with difficulties. These barriers have so far limited translation of TERM science into clinical treatments. It is crucial for primary researchers to be aware of the barriers currently restricting the progression of science to treatments. Researchers need to act prospectively to ensure the clinical, financial, and regulatory hurdles which seem so far removed from laboratory science do not stall or prevent the subsequent translation of their idea into a treatment. The aim of this review is to explore the development and translation of new treatments. Increasing the understanding of these complexities and barriers among primary researchers could enhance the efficiency of biomaterial translation.


Asunto(s)
Materiales Biocompatibles , Tratamiento Basado en Trasplante de Células y Tejidos , Medicina Regenerativa/tendencias , Investigación/tendencias , Ingeniería de Tejidos , Envejecimiento/fisiología , Animales , Humanos
3.
Tissue Eng Part A ; 30(5-6): 214-224, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38126344

RESUMEN

Many surgical tendon repairs fail despite advances in surgical materials and techniques. Tendon repair failure can be partially attributed to the tendon's poor intrinsic healing capacity and the repurposing of sutures from other clinical applications. Electrospun materials show promise as a biological scaffold to support endogenous tendon repair, but their relatively low tensile strength has limited their clinical translation. It is hypothesized that combining electrospun fibers with a material with increased tensile strength may improve the suture's mechanical properties while retaining biophysical cues necessary to encourage cell-mediated repair. This article describes the production of a hybrid electrospun-extruded suture with a sheath of submicron electrospun fibers and a core of melt-extruded fibers. The porosity and tensile strength of this hybrid suture is compared with an electrospun-only braided suture and clinically used sutures Vicryl and polydioxanone (PDS). Bioactivity is assessed by measuring the adsorbed serum proteins on electrospun and melt-extruded filaments using mass spectrometry. Human hamstring tendon fibroblast attachment and proliferation were quantified and compared between the hybrid and control sutures. Combining an electrospun sheath with melt-extruded cores created a hybrid braid with increased tensile strength (70.1 ± 0.3N) compared with an electrospun only suture (12.9 ± 1 N, p < 0.0001). The hybrid suture had a similar force at break to clinical sutures, but lower stiffness and stress. The Young's modulus was 772.6 ± 32 MPa for the hybrid suture, 1693.0 ± 69 MPa for PDS, and 3838.0 ± 132 MPa for Vicryl, p < 0.0001. Hybrid sutures had lower overall porosity than electrospun-only sutures (40 ± 4% and 60 ± 7%, respectively, p = 0.0018) but had a significantly larger overall porosity and average pore diameter compared with surgical sutures. There were similar clusters of adsorbed proteins on electrospun and melt-extruded filaments, which were distinct from PDS. Tendon fibroblast attachment and cell proliferation on hybrid and electrospun sutures were significantly higher than on clinical sutures. This study demonstrated that a bioactive suture with increased tensile strength and lower stiffness could be produced by adding a core of 10 µm melt-extruded fibers to a sheath of electrospun fibers. In contrast to currently used sutures, the hybrid sutures promoted a bioactive response: serum proteins adsorbed, and fibroblasts attached, survived, grew along the sutures, and adopted appropriate morphologies.


Asunto(s)
Polidioxanona , Poliglactina 910 , Humanos , Técnicas de Sutura , Tendones/cirugía , Suturas , Resistencia a la Tracción , Proteínas Sanguíneas
4.
J Shoulder Elbow Surg ; 21(9): 1168-76, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22079767

RESUMEN

BACKGROUND: Augmentation of rotator cuff tears aims to strengthen the repair and reduce rerupture, yet studies still report high failure rates. This study determines key mechanical properties of rotator cuff repair patches, including establishing values for toughness and measuring the shear properties of repair patches and human rotator cuff tendons. We hypothesized that different repair grafts would (1) have varying material parameters, and (2) not all have mechanical properties similar to human rotator cuff tendons. MATERIALS AND METHODS: Eight specimens each from the Restore, GraftJacket, Zimmer Collagen Repair, and SportsMesh repair patches were tested to failure in tension and for suture pullout. We assessed ultimate tensile strength, tensile (Young's) modulus, and failure strain. This study also established toughness values and shear data. Storage modulus was calculated using dynamic shear analysis for the patches and 18 samples of normal rotator cuff tendon. RESULTS: We report significant variability in important mechanical properties of repair patches, with the mechanical parameters of the patches diverting variously-and often significantly-from values for human rotator cuff tendon. CONCLUSIONS: The repair grafts tested all displayed significant variation in their mechanical properties and had at least some reduced parameters compared with human rotator cuff tendons. This study offers experimentally derived information of value to surgeons when selecting rotator cuff repair grafts. A better understanding of the mechanical suitability of repair grafts for supporting human rotator cuffs is needed if repair patches are to provide a solution for the clinical problem of failure of rotator cuff repairs.


Asunto(s)
Materiales Biocompatibles , Prótesis e Implantes , Lesiones del Manguito de los Rotadores , Manguito de los Rotadores/cirugía , Fenómenos Biomecánicos , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Resistencia a la Tracción
5.
Sci Rep ; 10(1): 4754, 2020 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-32179829

RESUMEN

We investigated endogenous tissue response to a woven and electrospun polydioxanone (PDO) and polycaprolactone (PCL) patch intended for tendon repair. A sheep tendon injury model characterised by a natural history of consistent failure of healing was chosen to assess the biological potential of woven and aligned electrospun fibres to induce a reparative response. Patches were implanted into 8 female adult English Mule sheep. Significant infiltration of tendon fibroblasts was observed within the electrospun component of the patch but not within the woven component. The cellular infiltrate into the electrospun fibres was accompanied by an extensive network of new blood vessel formation. Tendon fibroblasts were the most abundant scaffold-populating cell type. CD45+, CD4+ and CD14+ cells were also present, with few foreign body giant cells. There were no local or systemic signs of excessive inflammation with normal hematology and serology for inflammatory markers three months after scaffold implantation. In conclusion, we demonstrate that an endogenous healing response can be safely induced in tendon by means of biophysical cues using a woven and electrospun patch.


Asunto(s)
Fibroblastos/fisiología , Procedimientos de Cirugía Plástica/métodos , Polidioxanona , Poliésteres , Traumatismos de los Tendones/cirugía , Tendones/cirugía , Andamios del Tejido , Animales , Modelos Animales de Enfermedad , Femenino , Ovinos , Traumatismos de los Tendones/fisiopatología , Tendones/citología , Cicatrización de Heridas
6.
PLoS One ; 15(6): e0234982, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32589672

RESUMEN

BACKGROUND: Rotator cuff tendon repair in humans is a commonly performed procedure aimed at restoring the tendon-bone interface. Despite significant innovation of surgical techniques and suture anchor implants, only 60% of repairs heal successfully. One strategy to enhance repair is the use of bioactive sutures that provide the native tendon with biophysical cues for healing. We investigated the tissue response to a multifilament electrospun polydioxanone (PDO) suture in a sheep tendon injury model characterised by a natural history of failure of healing. METHODOLOGY AND RESULTS: Eight skeletally mature English Mule sheep underwent repair with electrospun sutures. Monofilament sutures were used as a control. Three months after surgery, all tendon repairs healed, without systemic features of inflammation, signs of tumour or infection at necropsy. A mild local inflammatory reaction was seen. On histology the electrospun sutures were densely infiltrated with predominantly tendon fibroblast-like cells. In comparison, no cellular infiltration was observed in the control suture. Neovascularisation was observed within the electrospun suture, whilst none was seen in the control. Foreign body giant cells were rarely seen with either sutures. CONCLUSION: This study demonstrates that a tissue response can be induced in tendon with a multifilament electrospun suture with no safety concerns.


Asunto(s)
Polidioxanona/efectos adversos , Complicaciones Posoperatorias/patología , Lesiones del Manguito de los Rotadores/cirugía , Técnicas de Sutura/instrumentación , Suturas/efectos adversos , Animales , Modelos Animales de Enfermedad , Femenino , Humanos , Complicaciones Posoperatorias/etiología , Manguito de los Rotadores/patología , Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/patología , Ovinos , Técnicas de Sutura/efectos adversos , Resistencia a la Tracción
7.
PLoS One ; 14(4): e0214419, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31022203

RESUMEN

Electrospun filaments are leading to a new generation of medical yarns that have the ability to enhance tissue healing through their biophysical cues. We have recently developed a technology to fabricate continuous electrospun filaments by depositing the submicron fibres onto a thin wire. Here we investigate the influence of pyridine on the fibre deposition. We have added pyridine to polydioxanone solutions at concentrations ranging from 0 to 100 ppm, increasing the conductivity of the solutions almost linearly from 0.04 uS/cm to 7 uS/cm. Following electrospinning, this led to deposition length increasing from 1 cm to 14 cm. The samples containing pyridine easily underwent cold drawing. The strength of drawn filaments increased from 0.8 N to 1.5 N and this corresponded to a decrease in fibre diameter, with values dropping from 2.7 µm to 1 µm. Overall, these findings are useful to increase the reliability of the manufacturing process of continuous electrospun filaments and to vary their biophysical properties required for their application as medical yarns such as surgical sutures.


Asunto(s)
Fenómenos Biofísicos , Nanofibras/química , Piridinas/química , Resistencia a la Tracción , Conductividad Eléctrica , Humanos , Polidioxanona/química , Poliésteres/química , Soluciones/química , Suturas , Andamios del Tejido/química
8.
Int J Nanomedicine ; 12: 3977-3991, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28579781

RESUMEN

Electrospun filaments represent a new generation of medical textiles with promising applications in soft tissue repair. A potential strategy to improve their design is to combine them with bioactive molecules. Curcumin, a natural compound found in turmeric, is particularly attractive for its antioxidant, anti-inflammatory, and antimicrobial properties. However, investigating the range of relevant doses of curcumin in materials designed for tissue regeneration has remained limited. In this paper, a wide range of curcumin concentrations was explored and the potential of the resulting materials for soft tissue repair applications was assessed. Polydioxanone (PDO) filaments were prepared with various amounts of curcumin: 0%, 0.001%, 0.01%, 0.1%, 1%, and 10% (weight to weight ratio). The results from the present study showed that, at low doses (≤0.1%), the addition of curcumin has no influence on the spinning process or on the physicochemical properties of the filaments, whereas higher doses lead to smaller fiber diameters and improved mechanical properties. Moreover, filaments with 0.001% and 0.01% curcumin stimulate the metabolic activity and proliferation of normal human dermal fibroblasts (NHDFs) compared with the no-filament control. However, this stimulation is not significant when compared to the control filaments (0%). Highly dosed filaments induce either the inhibition of proliferation (with 1%) or cell apoptosis (with 10%) as a result of the concentrations of curcumin found in the medium (9 and 32 µM, respectively), which are near or above the known toxicity threshold of curcumin (~10 µM). Moreover, filaments with 10% curcumin increase the catalase activity and glutathione content in NHDFs, indicating an increased production of reactive oxygen species resulting from the large concentration of curcumin. Overall, this study suggested that PDO electrospun filaments loaded with low amounts of curcumin are more promising compared with higher concentrations for stimulating tissue repair. This study also highlighted the need to explore lower concentrations when using polymers as PDO, such as those with polycaprolactone and other degradable polyesters.


Asunto(s)
Curcumina/química , Polidioxanona/química , Andamios del Tejido/química , Adhesión Celular , Proliferación Celular , Células Cultivadas , Curcumina/farmacología , Liberación de Fármacos , Fibroblastos/citología , Fibroblastos/efectos de los fármacos , Fibroblastos/metabolismo , Glutatión/metabolismo , Humanos , Fenómenos Mecánicos , Microscopía Electrónica de Rastreo , Textiles
9.
J Biomed Mater Res A ; 104(11): 2843-53, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27399850

RESUMEN

Bioengineered tissue scaffolds in combination with cells hold great promise for tissue regeneration. The aim of this study was to determine how the chemistry and fiber orientation of engineered scaffolds affect the differentiation of mesenchymal stem cells (MSCs). Adipogenic, chondrogenic, and osteogenic differentiation on aligned and randomly orientated electrospun scaffolds of Poly (lactic-co-glycolic) acid (PLGA) and Polydioxanone (PDO) were compared. MSCs were seeded onto scaffolds and cultured for 14 days under adipogenic-, chondrogenic-, or osteogenic-inducing conditions. Cell viability was assessed by alamarBlue metabolic activity assays and gene expression was determined by qRT-PCR. Cell-scaffold interactions were visualized using fluorescence and scanning electron microscopy. Cells grew in response to scaffold fiber orientation and cell viability, cell coverage, and gene expression analysis showed that PDO supports greater multilineage differentiation of MSCs. An aligned PDO scaffold supports highest adipogenic and osteogenic differentiation whereas fiber orientation did not have a consistent effect on chondrogenesis. Electrospun scaffolds, selected on the basis of fiber chemistry and alignment parameters could provide great therapeutic potential for restoration of fat, cartilage, and bone tissue. This study supports the continued investigation of an electrospun PDO scaffold for tissue repair and regeneration and highlights the potential of optimizing fiber orientation for improved utility. © 2016 The Authors Journal of Biomedical Materials Research Part A Published by Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 2843-2853, 2016.


Asunto(s)
Materiales Biocompatibles/química , Diferenciación Celular , Ácido Láctico/química , Células Madre Mesenquimatosas/citología , Polidioxanona/química , Ácido Poliglicólico/química , Andamios del Tejido/química , Materiales Biocompatibles/metabolismo , Supervivencia Celular , Células Cultivadas , Expresión Génica , Humanos , Ácido Láctico/metabolismo , Células Madre Mesenquimatosas/metabolismo , Polidioxanona/metabolismo , Ácido Poliglicólico/metabolismo , Copolímero de Ácido Poliláctico-Ácido Poliglicólico
10.
Biomaterials ; 109: 55-68, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27669498

RESUMEN

Oxidative stress occurs when the production of oxidants surpasses the antioxidant capacity in living cells. Oxidative stress is implicated in a number of pathological conditions such as cardiovascular and neurodegenerative diseases but it also has crucial roles in the regulation of cellular activities. Over the last few decades, many studies have identified significant connections between oxidative stress, inflammation and healing. In particular, increasing evidence indicates that the production of oxidants and the cellular response to oxidative stress are intricately connected to the fate of implanted biomaterials. This review article provides an overview of the major mechanisms underlying the link between oxidative stress and the biocompatibility of biomaterials. ROS, RNS and lipid peroxidation products act as chemo-attractants, signalling molecules and agents of degradation during the inflammation and healing phases. As chemo-attractants and signalling molecules, they contribute to the recruitment and activation of inflammatory and healing cells, which in turn produce more oxidants. As agents of degradation, they contribute to the maturation of the extracellular matrix at the healing site and to the degradation of the implanted material. Oxidative stress is itself influenced by the material properties, such as by their composition, their surface properties and their degradation products. Because both cells and materials produce and react with oxidants, oxidative stress may be the most direct route mediating the communication between cells and materials. Improved understanding of the oxidative stress mechanisms following biomaterial implantation may therefore help the development of new biomaterials with enhanced biocompatibility.


Asunto(s)
Antioxidantes/metabolismo , Materiales Biocompatibles/uso terapéutico , Estrés Oxidativo , Prótesis e Implantes , Animales , Materiales Biocompatibles/efectos adversos , Materiales Biocompatibles/química , Humanos , Inflamación/inducido químicamente , Inflamación/metabolismo , Peroxidación de Lípido , Oxidantes/metabolismo , Especies de Nitrógeno Reactivo/metabolismo , Especies Reactivas de Oxígeno/metabolismo , Ingeniería de Tejidos , Cicatrización de Heridas/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA