Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Small ; 18(52): e2205095, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36373681

RESUMEN

High-performance X-ray detectors have immense potential in medical and security inspections. However, the current X-ray detectors are limited in flexible, high-spatial-resolution large-scale detection, and integration for imaging. Here, nuclear track-etched porous polyethylene terephthalate (PET) is developed as the template for preparing uniform, large-area (≥105 cm2 ), and flexible metal halide (MH)-based X-ray detectors. Adjustable high-density vertically oriented porous PET with adjustable thickness can provide proper physical support for flexible thick absorption film, thus improving X-ray absorption ability with excellent bending stability. Moreover, vertical channels can block the ion migration, lateral charge diffusion, and water/oxygen attacks, increasing activation energy for ionic transport, charge collection rate of electrodes, and environmental stability. Hence, the related detectors eventually obtain large sensitivity (6722 µC Gyair -1 cm-2 ), low detection limit (1.87 nGyair s-1 ), and high spatial resolution (5.17 lp mm-1 ) compared to the detectors without porous PET template. Meanwhile, the device shows no degradation after storage or working under various thermal attacks. MH-filled-PET is also monolithically integrated on the bottom circuit with different MHs and it is applied to single-pixel mode and fast linear-array imaging in a broad range of X-rays photon energy (20 to 160 keV).


Asunto(s)
Compuestos Inorgánicos , Tereftalatos Polietilenos , Rayos X , Porosidad , Metales , Tomografía de Emisión de Positrones
2.
Environ Res ; 182: 109150, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32069768

RESUMEN

The gradual updating of the water supply network is one of the crucial ways to ensure the safety of drinking water all over the world. The phenomenon and regularity of the biological risk and chemical risk of biofilms of the new pipes in drinking water distribution system (DWDS) is inadequate researched by now. In order to explore the biochemical risks of biofilms after new pipes are used, this paper studied the growth of biofilms, the content of disinfection by-products (DBPs) and the potential for disinfection by-products (DBPsFP) after 2-year use by establishing a pilot test platform at both ends of the DWDS in City S. The results showed that the total bacterial count in new pipelines was between 1.38 × 108-9.97 × 108/cm2; the DBPsFP at the front end and at the back end was subtly different. The overall DBPsFP of biofilms was the highest, followed by the ductile cast iron pipe and the galvanized pipe whereas the stainless steel pipe was the lowest. The HPC content of the 2-year-old pipe (1.68 × 105-7.09 × 106 CFU/cm2) was remarkably higher than that of the 1-year-old pipe (1.04 × 105-8.76 × 105 CFU/cm2), and the generation DBPsFP was about 50% higher. When a new pipeline was put into use in the urban drinking water distribution system, biofilms with certain biological hazards and risks of DBPs disinfection by-products would form in a short period of time.


Asunto(s)
Biopelículas , Agua Potable , Purificación del Agua , Desinfección , Acero Inoxidable , Microbiología del Agua , Abastecimiento de Agua
3.
Implant Dent ; 26(3): 405-411, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28125517

RESUMEN

PURPOSE: This study examined (1) if cone-beam computed tomography (CBCT) can determine relative differences in bone mineral density distribution using clinical images of patients' mandibular bone and (2) if the relative differences can be used to detect the effects of sex and age on bone mineral density distribution. MATERIALS AND METHODS: Sixty-six clinical CBCT images from patients (36 females and 30 males) of 3 age groups (40, 50, and 60 years) were identified. Alveolar (AB) and basal cortical bone (CB) regions were digitally isolated. A histogram of gray levels, which are proportional to degrees of bone mineralization, was obtained from each region. Mean, variability (SD and coefficient of variation), and percentage differences of gray level parameters between AB and basal CBs were computed. RESULTS: Significant sex differences in gray level variability were observed within the postmenopausal age group (P < 0.042). CONCLUSION: These findings suggest that clinical CBCT images can be a valuable tool in providing information on bone quality, which is an important criterion for optimum planning for dental implant placement.


Asunto(s)
Proceso Alveolar/diagnóstico por imagen , Densidad Ósea , Tomografía Computarizada de Haz Cónico/métodos , Implantación Dental Endoósea , Mandíbula/diagnóstico por imagen , Planificación de Atención al Paciente , Adulto , Calcificación Fisiológica , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
4.
ACS Sens ; 9(8): 3848-3863, 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39046083

RESUMEN

Flexible piezoresistive sensors are in high demand in areas such as wearable devices, electronic skin, and human-machine interfaces due to their advantageous features, including low power consumption, excellent bending stability, broad testing pressure range, and simple manufacturing technology. With the advancement of intelligent technology, higher requirements for the sensitivity, accuracy, response time, measurement range, and weather resistance of piezoresistive sensors are emerging. Due to the designability of polymer porous materials and conductive phases, and with more multivariate combinations, it is possible to achieve higher sensitivity and lower detection limits, which are more promising than traditional flexible sensor materials. Based on this, this work reviews recent advancements in research on flexible pressure sensors utilizing polymer porous materials. Furthermore, this review examines sensor performance optimization and development from the perspectives of three-dimensional porous flexible substrate regulation, sensing material selection and composite technology, and substrate and sensing material structure design.


Asunto(s)
Polímeros , Dispositivos Electrónicos Vestibles , Porosidad , Polímeros/química , Humanos , Presión
5.
J Clin Oncol ; 42(19): 2317-2326, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38648575

RESUMEN

PURPOSE: The phase III RESILIENT trial compared second-line liposomal irinotecan with topotecan in patients with small cell lung cancer (SCLC). PATIENTS AND METHODS: Patients with SCLC and progression on or after first-line platinum-based chemotherapy were randomly assigned (1:1) to intravenous (IV) liposomal irinotecan (70 mg/m2 every 2 weeks in a 6-week cycle) or IV topotecan (1.5 mg/m2 daily for 5 consecutive days, every 3 weeks in a 6-week cycle). The primary end point was overall survival (OS). Key secondary end points included progression-free survival (PFS) and objective response rate (ORR). RESULTS: Among 461 randomly assigned patients, 229 received liposomal irinotecan and 232 received topotecan. The median follow-up was 18.4 months. The median OS was 7.9 months with liposomal irinotecan versus 8.3 months with topotecan (hazard ratio [HR], 1.11 [95% CI, 0.90 to 1.37]; P = .31). The median PFS per blinded independent central review (BICR) was 4.0 months with liposomal irinotecan and 3.3 months with topotecan (HR, 0.96 [95% CI, 0.77 to 1.20]; nominal P = .71); ORR per BICR was 44.1% (95% CI, 37.6 to 50.8) and 21.6% (16.4 to 27.4), respectively. Overall, 42.0% and 83.4% of patients receiving liposomal irinotecan and topotecan, respectively, experienced grade ≥3 related treatment-emergent adverse events (TEAEs). The most common grade ≥3 related TEAEs were diarrhea (13.7%), neutropenia (8.0%), and decreased neutrophil count (4.4%) with liposomal irinotecan and neutropenia (51.6%), anemia (30.9%), and leukopenia (29.1%) with topotecan. CONCLUSION: Liposomal irinotecan and topotecan demonstrated similar median OS and PFS in patients with relapsed SCLC. Although the primary end point of OS was not met, liposomal irinotecan demonstrated a higher ORR than topotecan. The safety profile of liposomal irinotecan was consistent with its known safety profile; no new safety concerns emerged.


Asunto(s)
Irinotecán , Liposomas , Neoplasias Pulmonares , Recurrencia Local de Neoplasia , Carcinoma Pulmonar de Células Pequeñas , Topotecan , Humanos , Topotecan/administración & dosificación , Topotecan/efectos adversos , Irinotecán/administración & dosificación , Irinotecán/efectos adversos , Irinotecán/uso terapéutico , Carcinoma Pulmonar de Células Pequeñas/tratamiento farmacológico , Carcinoma Pulmonar de Células Pequeñas/mortalidad , Carcinoma Pulmonar de Células Pequeñas/patología , Masculino , Femenino , Persona de Mediana Edad , Anciano , Neoplasias Pulmonares/tratamiento farmacológico , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/mortalidad , Adulto , Recurrencia Local de Neoplasia/tratamiento farmacológico , Anciano de 80 o más Años , Supervivencia sin Progresión , Inhibidores de Topoisomerasa I/administración & dosificación , Inhibidores de Topoisomerasa I/efectos adversos , Inhibidores de Topoisomerasa I/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA