Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
ACS Appl Mater Interfaces ; 12(13): 14876-14883, 2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-32155045

RESUMEN

Protein-supported nanoparticles have a great significance in scientific and nanotechnology research because of their "green" process, low cost-in-use, good biocompatibility, and some interesting properties. Ruthenium oxide nanoparticles (RuO2NPs) have been considered to be an important member in nanotechnology research. However, the biosynthetic approach of RuO2NPs is relatively few compared to those of other nanoparticles. To address this challenge, this work presented a new way for RuO2NP synthesis (BSA-RuO2NPs) supported by bovine serum albumin (BSA). BSA-RuO2NPs are confirmed to exert peroxidase-like activity, electrocatalytic activity, in vitro salt resistance (2 M NaCl), and biocompatibility. Results indicate that BSA-RuO2NPs have higher affinity binding for 3,3',5,5'-tetramethylbenzidine or H2O2 than bare RuO2NPs. Moreover, BSA turns out to be a crucial factor in promoting the stability of RuO2NPs. Taking the advantages of these improved properties, we established colorimetric (linear range from 2 to 800 µM, a limit of detection of 1.8 µM) and electrochemical (linear range from 0.4 to 3850 µM, a limit of detection of 0.18 µM) biosensors for monitoring in situ H2O2 secretion from living MCF-7 cells. Herein, this work offers a new biosynthesis strategy to obtain BSA-RuO2NPs and sheds light on the sensitive biosensors to monitor the H2O2 secreted from living cells for promising applications in the fields of nanotechnology, biology, biosensors, and medicine.


Asunto(s)
Materiales Biocompatibles/química , Técnicas Biosensibles/métodos , Peróxido de Hidrógeno/análisis , Nanopartículas del Metal/química , Compuestos de Rutenio/química , Albúmina Sérica Bovina/química , Cloruro de Sodio/química , Animales , Bencidinas/química , Catálisis , Bovinos , Colorimetría , Técnicas Electroquímicas , Electrodos , Humanos , Límite de Detección , Células MCF-7
2.
Clin Rheumatol ; 35(1): 165-73, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24924603

RESUMEN

This study is aimed at comparing the efficacy and safety of loxoprofen sodium hydrogel patch (LX-P) with loxoprofen sodium tablet (LX-T) in patients with knee osteoarthritis (OA). One hundred sixty-nine patients were enrolled in a randomized, controlled, double-blind, double-dummy, multicenter, non-inferiority trial of LX-P. Patients were randomly assigned to either LX-P or LX-T groups for a 4-week treatment. The primary efficacy endpoint was the proportion of patients with an overall improvement of ≥50%, and the secondary efficacy endpoint was the proportion of patients with an improvement of ≥25% from baseline in each of the seven main symptoms. The non-inferiority trial was based on a power of 80% and significance level of 2.5% with a non-inferiority margin of -10%. In both intention-to-treat (ITT) and per-protocol (PP) analyses, LX-P was as effective as LX-T in regard to the primary endpoint. In the ITT analysis, the difference between the two groups was 12.6% [95% confidence interval, -1.7 to 26.9%]. No significant differences were found between the two groups in any of the secondary efficacy outcomes. A lower incidence of adverse events was observed in LX-P group; however, the difference was not statistically significant. No serious adverse events were reported in the LX-P group, whereas one case was reported in LX-T group. Based on the present study, topical loxoprofen patch was non-inferior to oral loxoprofen in patients with knee osteoarthritis.


Asunto(s)
Antiinflamatorios no Esteroideos/administración & dosificación , Osteoartritis de la Rodilla/tratamiento farmacológico , Fenilpropionatos/administración & dosificación , Comprimidos , Parche Transdérmico , Anciano , Antiinflamatorios no Esteroideos/efectos adversos , China , Comorbilidad , Método Doble Ciego , Femenino , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato/efectos adversos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Fenilpropionatos/efectos adversos , Comprimidos/efectos adversos , Parche Transdérmico/efectos adversos , Resultado del Tratamiento
3.
Radiat Prot Dosimetry ; 151(1): 89-94, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22262816

RESUMEN

A new type of water phantom which would be specialised for the absorbed dose measurement in total body irradiation (TBI) treatment is developed. Ten millimetres of thick Plexiglas plates were arranged to form a square cube with 300 mm of edge length. An appropriate sleeve-type piston was installed on the side wall, and a tabular Plexiglas piston was positioned inside the sleeve. By pushing and pulling the piston, the length of the self-made water phantom could be varied to meet the required patients' physical sizes. To compare the international standard water phantom with the length-adjustable and the Plexiglas phantoms, absorbed dose for 6-MV X ray was measured by an ionisation chamber at different depths in three kinds of phantoms. In 70 cases with TBI, midplane doses were metered using the length-adjustable and the Plexiglas phantoms for simulating human dimensions, and dose validation was synchronously carried out. There were no significant statistical differences, p > 0.05, through statistical processing of data from the international standard water phantom and the self-designed one. There were significant statistical differences, p < 0.05, between the two sets of data from the standard and the Plexiglas one. In addition, the absolute difference had a positive correlation with the varied depth of the detector in the Plexiglas phantom. Comparing the data of clinical treatment, the differences were all <1 % among the prescription doses and the validation data collected from the self-design water phantom. However, the differences collected from the Plexiglas phantom were increasing gradually from +0.77 to +2.30 % along with increasing body width. Obviously, the difference had a positive correlation with the body width. The results proved that the new length-adjustable water phantom is more accurate for simulating human dimensions than Plexiglas phantom.


Asunto(s)
Fantasmas de Imagen , Agua/química , Irradiación Corporal Total , Humanos , Método de Montecarlo , Polimetil Metacrilato/química , Dosificación Radioterapéutica
4.
Bioelectrochemistry ; 75(1): 13-8, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19168399

RESUMEN

The amplified electrochemical sensing of DNA was accomplished by electrodeposited PEDOT on the electrode surface and incorporation of Nile blue (NB) as redox active intercalator into DNA. Herein, above modified electrode called as PEDOT/DNA/NB composite electrode. PEDOT/DNA/NB composite electrode exhibited well defined redox peak at -0.35 V (Ag/AgCl) corresponding to NB. The composite electrode surface coverage (Gamma) and DeltaEp were compared with PEDOT/NB and DNA/NB modified electrode. Atomic Force microscopy (AFM), and cyclic voltammetry (CV) were used to characterize the PEDOT/DNA/NB composite electrode. The composite electrode was exhibited as surface confined redox process in neutral pH. The composite electrode was found to be pH dependent. The composite electrode exhibited catalytic property towards reduction of hydrogen peroxide (H(2)O(2)). The composite electrode was utilized to amperometric study and its response towards H(2)O(2) detection was less than 6 s and the detection limit was 0.1 microM. Moreover, we tested PEDOT/DNA/NB composite electrode to electrocatalytic reduction of cytochrome c (Cyt c).


Asunto(s)
Técnicas de Química Analítica/métodos , ADN/análisis , ADN/química , Oxazinas/análisis , Oxazinas/química , Compuestos Bicíclicos Heterocíclicos con Puentes/química , Catálisis , Citocromos c/química , Citocromos c/metabolismo , ADN/ultraestructura , Técnicas Electroquímicas , Electrodos , Peróxido de Hidrógeno/química , Microscopía de Fuerza Atómica , Oxidación-Reducción , Polímeros/química , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA