Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Acta Neurochir (Wien) ; 165(4): 897-904, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36820888

RESUMEN

PURPOSE: Radiolucent anterior and posterior implants by carbon fiber-reinforced polyetheretherketone (CFR PEEK) aim to improve treatment of primary and secondary tumors of the spine during the last years. The aim of this study was to evaluate clinical and radiological outcomes after dorsoventral instrumentation using a CFR PEEK implant in a cohort of patients representing clinical reality. METHODS: A total of 25 patients with tumor manifestation of the thoracic and lumbar spine underwent vertebral body replacement (VBR) using an expandable CFR PEEK implant between January 2021 and January 2022. Patient outcome, complications, and radiographic follow-up were analyzed. RESULTS: A consecutive series aged 65.8 ± 14.7 (27.6-91.2) years were treated at 37 vertebrae of tumor manifestation, including two cases (8.0%) of primary tumor as well as 23 cases (92.0%) of spinal metastases. Overall, 26 cages covering a median of 1 level (1-4) were implanted. Duration of surgery was 134 ± 104 (65-576) min, with a blood loss of 792 ± 785 (100-4000) ml. No intraoperative cage revision was required. Surgical complications were reported in three (12.0%) cases including hemothorax in two cases (one intraoperative, one postoperative) and atrophic wound healing disorder in one case. In two cases (8.0%), revision surgery was performed (fracture of the adjacent tumorous vertebrae, progressive construct failure regarding cage subsidence). No implant failure was observed. CONCLUSION: VBR using CFR PEEK cages represents a legitimate surgical strategy which opens a variety of improvements-especially in patients in need of postoperative radiotherapy of the spine and MRI-based follow-up examinations.


Asunto(s)
Neoplasias , Fusión Vertebral , Humanos , Fibra de Carbono , Cuerpo Vertebral , Resultado del Tratamiento , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Polietilenglicoles , Cetonas , Estudios Retrospectivos
2.
J Appl Clin Med Phys ; 21(8): 6-14, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32476247

RESUMEN

BACKGROUND: Throughout the last years, carbon-fibre-reinforced PEEK (CFP) pedicle screw systems were introduced to replace standard titanium alloy (Ti) implants for spinal instrumentation, promising improved radiotherapy (RT) treatment planning accuracy. We compared the dosimetric impact of both implants for intensity modulated proton (IMPT) and volumetric arc photon therapy (VMAT), with the focus on uncertainties in Hounsfield unit assignment of titanium alloy. METHODS: Retrospective planning was performed on CT data of five patients with Ti and five with CFP implants. Carbon-fibre-reinforced PEEK systems comprised radiolucent pedicle screws with thin titanium-coated regions and titanium tulips. For each patient, one IMPT and one VMAT plan were generated with a nominal relative stopping power (SP) (IMPT) and electron density (ρ) (VMAT) and recalculated onto the identical CT with increased and decreased SP or ρ by ±6% for the titanium components. RESULTS: Recalculated VMAT dose distributions hardly deviated from the nominal plans for both screw types. IMPT plans resulted in more heterogeneous target coverage, measured by the standard deviation σ inside the target, which increased on average by 7.6 ± 2.3% (Ti) vs 3.4 ± 1.2% (CFP). Larger SPs lead to lower target minimum doses, lower SPs to higher dose maxima, with a more pronounced effect for Ti screws. CONCLUSIONS: While VMAT plans showed no relevant difference in dosimetric quality between both screw types, IMPT plans demonstrated the benefit of CFP screws through a smaller dosimetric impact of CT-value uncertainties compared to Ti. Reducing metal components in implants will therefore improve dose calculation accuracy and lower the risk for tumor underdosage.


Asunto(s)
Terapia de Protones , Radioterapia de Intensidad Modulada , Aleaciones , Benzofenonas , Fibra de Carbono , Humanos , Cetonas , Fotones , Polietilenglicoles , Polímeros , Protones , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos , Titanio
3.
Strahlenther Onkol ; 195(6): 475-481, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30523417

RESUMEN

BACKGROUND: The goal of this study was to investigate if daily dose recalculations are necessary or if less time-consuming approaches can be used to identify dose differences to the planned dose in patients with head and neck cancers (H&N). METHODS: For 12 H&N patients treated with helical tomotherapy, daily dose calculations were performed retrospectively. Four different summation doses (SuDo) were calculated: DayDo (daily dose calculation), MVCTx2, MVCTx5, and MVCTx10 (dose calculations every second, fifth, and tenth fraction). Dose recalculations were depicted on the last contoured mega voltage CT (MVCT). The DayDo was compared to the planned dose and to the less time-consuming SuDo scenarios. The doses were assessed for the planning target volume (PTV) and the organs at risk (OARs): mandible (mand), spinal cord (SC), spinal cord +5 mm (SC+5 mm), parotid glands (PG). RESULTS: The ipsilateral PG, contralateral PG, and PTV volume decreased by -22.5% (range: -34.8 to 5.2%), -19.5% (-31.5 to 15.8%), and -2.6% (-16.7 to 0.2%), respectively. There was a significant median mean dose (Dmean) dose difference for DayDo compared to the planned dose for PG total of 1.9 Gy (-3.3 to 7.3 Gy). But less time-consuming SuDo compared to DayDo showed statistically significant but not clinically relevant (<2%) dose differences for several organs. Hence the small dose difference to the gold standard (DayDo), we recommend dose recalculations every fifth MVCT in order to identify the occurrence of dose differences compared to the planned dose. CONCLUSION: Daily dose calculations are the most precise to assess dose differences between actual and planned dose. Dose recalculations on every fifth MVCT (i. e., weekly control CTs) are an applicable and time-saving way of identifying patients with significant dose differences compared to the planned dose.


Asunto(s)
Neoplasias de Oído, Nariz y Garganta/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Radioterapia de Intensidad Modulada/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Órganos en Riesgo/efectos de la radiación , Factores de Tiempo
4.
Radiat Oncol ; 14(1): 66, 2019 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-30992022

RESUMEN

BACKGROUND: Multimodal treatment with neoadjuvant chemoradiation followed by surgery (nCRT + S) is the treatment of choice for patients with locally advanced or node-positive esophageal squamous cell carcinoma (E-SCC). Those who are unsuitable or who decline surgery can be treated with definitive chemoradiation (dCRT). This study compares the oncologic outcome of nCRT + S and dCRT in E-SCC patients. METHODS: Between 2011 and 2017, 95 patients with E-SCC were scheduled for dCRT or nCRT+ S with IMRT at our department. Patients undergoing dCRT received at least 50 Gy and those undergoing nCRT + S received at least 41.4 Gy. All patients received simultaneous chemotherapy with either carboplatin and paclitaxel or cisplatin and 5-fluoruracil. We retrospectively compared baseline characteristics and oncologic outcome including overall survival (OS), progression-free survival (PFS) and site of failure between both treatment groups. RESULTS: Patients undergoing dCRT were less likely to have clinically suspected lymph node metastases (85% vs. 100%, p = 0.019) than patients undergoing nCRT + S and had more proximally located tumors (median distance from dental arch to cranial tumor border 20 cm vs. 26 cm, p < 0.001). After a median follow up of 25.6 months for surviving patients, no significant differences for OS and PFS were noticed comparing nCRT + S and dCRT. However, the rate of local tumor recurrence was significantly higher in patients treated with dCRT than in those treated with nCRT + S (38% vs. 10%, p = 0.002). Within a multivariate Cox regression model, age, tumor location, and tumor grading were the only independent parameters affecting OS and PFS. In addition to that, proximal tumor location was the only parameter independently associated with an increased risk for local treatment failure. CONCLUSION: In E-SCC patients treated with either dCRT or nCRT + S, a higher rate of local tumor recurrence was seen in patients treated with dCRT than in patients treated with nCRT + S. There was at least a trend towards an improved OS and PFS in patients undergoing nCRT + S. However, this should be interpreted with caution, because proximal tumor location was the only parameter independently affecting the risk of local tumor recurrence.


Asunto(s)
Carcinoma de Células Escamosas/terapia , Quimioradioterapia/mortalidad , Neoplasias Esofágicas/terapia , Terapia Neoadyuvante/mortalidad , Anciano , Carcinoma de Células Escamosas/patología , Neoplasias Esofágicas/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Tasa de Supervivencia
5.
World Neurosurg ; 105: 294-301, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28478252

RESUMEN

OBJECTIVE: Surgical treatment of spinal tumors regularly includes spinal instrumentation with pedicle screws. Most modern pedicle screws are made of titanium alloy, which is associated with artifacts on postoperative imaging such as computed tomography and/or magnetic resonance imaging. These artifacts hamper radiation treatment planning and execution and follow-up imaging. Recently, carbon fiber-reinforced polyetheretherketone (CFRP) implants became available for posterior instrumentation with the aim to reduce imaging artifacts by implants. METHODS: Patients harboring spinal tumors underwent posterior stabilization using CFRP pedicle screws. Postoperative imaging was evaluated for implant artifacts. Radiation planning was assessed. RESULTS: Thirty-five patients with spinal tumors were assessed (metastases n = 30; lymphoma n = 2, myeloma n = 1, chordoma n = 1, fibrous dysplasia n = 1). Implantation of CFRP implants was feasible in all but 1 case. Postoperative images show reduced artifacts in comparison with standard titanium alloy implants. Implant position and integrity is sufficiently assessable despite reduced image contrast. Radiation planning is improved. CONCLUSIONS: Carbon fiber-reinforced PEEK pedicle screws reduce image artifacts on computed tomography and magnetic resonance imaging. Thereby, they are a valuable and feasible option for spinal instrumentations in patients harboring spinal tumors where postoperative imaging and radiation therapy planning are necessary and might be crucial for long-term outcome and overall survival.


Asunto(s)
Carbono/uso terapéutico , Tornillos Pediculares , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Neoplasias de la Columna Vertebral/diagnóstico por imagen , Neoplasias de la Columna Vertebral/terapia , Anciano , Anciano de 80 o más Años , Benzofenonas , Fibra de Carbono , Femenino , Estudios de Seguimiento , Humanos , Cetonas/uso terapéutico , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Polietilenglicoles/uso terapéutico , Polímeros , Cuidados Posoperatorios/métodos , Radioterapia/métodos , Estudios Retrospectivos , Tomógrafos Computarizados por Rayos X , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA