Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Arch Toxicol ; 89(2): 201-10, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24792325

RESUMEN

8-Oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodGuo) is the most investigated product of oxidatively damaged DNA lesion that has been associated with the development of aging, cancer and some degenerative diseases. Here, we present the first liquid chromatography-tandem mass spectrometry method that enables the simultaneous measurement of its repair products in plasma and saliva, namely 8-oxo-7,8-dihydroguanine (8-oxoGua) and 8-oxodGuo. Using this method, we investigated the underlying transport mechanism of the repair products of oxidatively damaged DNA between cellular compartments and biological matrices. Plasma, saliva and urine samples were collected concurrently from 57 healthy subjects. Various deproteinization methods were evaluated, and the precipitants acetonitrile and sodium hydroxide-methanol were, respectively, selected for plasma and saliva samples due to their effect on recovery efficiencies and chromatography. The mean baseline concentrations of 8-oxoGua and 8-oxodGuo in plasma were demonstrated to be 0.21 and 0.016 ng/mL, respectively, while in saliva they were 0.85 and 0.010 ng/mL, respectively. A relatively high concentration of 8-oxoGua was found in saliva with a concentration factor (CF, concentration ratio of saliva to plasma) of 4 as compared to that of 8-oxodGuo (CF: 0.6), implying that 8-oxoGua in plasma may be actively transported to saliva, whereas 8-oxodGuo was most dependent on a passive diffusion. Good correlations between urine and plasma concentrations were observed for 8-oxoGua and 8-oxodGuo, suggesting that blood was a suitable matrix in addition to urine. Significant correlation between 8-oxoGua and 8-oxodGuo in urine was only observed when the concentrations were not corrected for urinary creatinine, raising the issue of applicability of urinary creatinine to adjust 8-oxoGua concentrations.


Asunto(s)
Desoxiadenosinas/análisis , Guanina/análogos & derivados , Adulto , Cromatografía Liquida , Desoxiadenosinas/sangre , Desoxiadenosinas/orina , Guanina/análisis , Guanina/sangre , Guanina/orina , Humanos , Saliva/química , Extracción en Fase Sólida , Espectrometría de Masas en Tándem
2.
Photochem Photobiol ; 98(3): 609-616, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34706095

RESUMEN

Some early reports demonstrate that levels of cyclobutane pyrimidine dimers (CPD) may increase after UVR exposure had ended, although these observations were treated as artifacts. More recently, it has been shown unequivocally that CPD formation does occur post-irradiation, with maximal levels occurring after about 2-3 h. These lesions have been termed "dark CPD" (dCPD). Subsequent studies have confirmed their presence in vitro, in mouse models and in human skin in vivo. Melanin carbonyls have a role in the formation of dCPD, but they have also been observed in amelanotic systems, indicating other, unknown process(es) exist. In both cases, the formation of dCPD can be prevented by the presence of certain antioxidants. We lack data on the spectral dependence of dCPD, but it is unlikely to be the same as for incident CPD (iCPD), which are formed only during irradiation. There is evidence that iCPD and dCPD may have different repair kinetics, although this remains to be elucidated. It is also unknown whether iCPD and dCPD have different biological properties. The formation of dCPD in human skin in vivo has implications for post solar exposure photoprotection, and skin carcinogenesis, with a need for this to be investigated further.


Asunto(s)
Daño del ADN , Dímeros de Pirimidina , Animales , Reparación del ADN , Melaninas , Ratones , Polímeros , Dímeros de Pirimidina/efectos de la radiación , Piel/efectos de la radiación , Rayos Ultravioleta
3.
Free Radic Biol Med ; 41(12): 1829-36, 2006 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-17157185

RESUMEN

While ELISA is a frequently used means of assessing 8-oxo-7,8-dihydro-2-deoxyguanosine (8-oxodG) in biological fluids, differences in baseline urinary 8-oxodG levels, compared to chromatographic techniques, have raised questions regarding the specificity of immunoassays. Recently, ELISA of salivary 8-oxodG has been used to report on periodontal disease. We compared salivary 8-oxodG levels, determined by two commercial ELISA kits, to liquid chromatography-tandem mass spectrometry (LC-MS/MS) with prior purification using solid-phase extraction. While values were obtained with both ELISA kits, salivary 8-oxodG values were below or around the limit of detection of our LC-MS/MS assay. As the limit of detection for the LC-MS/MS procedure is much lower than ELISA, we concluded that the assessment of salivary 8-oxodG by ELISA is not accurate. In contrast to previous studies, ELISA levels of urinary 8-oxodG (1.67 +/- 0.53 pmol/mumol creatinine) were within the range reported previously only for chromatographic assays, although still significantly different than LC-MS/MS (0.41 +/- 0.39 pmol/mumol creatinine; p = 0.002). Furthermore, no correlation with LC-MS/MS was seen. These results question the ability of ELISA approaches, at present, to specifically determine absolute levels of 8-oxodG in saliva and urine. Ongoing investigation in our laboratories aims to identify the basis of the discrepancy between ELISA and LC-MS/MS.


Asunto(s)
Cromatografía Liquida/métodos , Desoxiguanosina/análogos & derivados , Ensayo de Inmunoadsorción Enzimática/métodos , Espectrometría de Masas/métodos , Saliva/química , 8-Hidroxi-2'-Desoxicoguanosina , Adulto , Desoxiguanosina/análisis , Desoxiguanosina/orina , Femenino , Humanos , Masculino , Persona de Mediana Edad
4.
Free Radic Biol Med ; 52(10): 2057-63, 2012 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-22542794

RESUMEN

Interaction of reactive oxygen species with DNA results in a variety of modifications, including 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG), which has been extensively studied as a biomarker of oxidative stress. Oxidative stress is implicated in a number of pathophysiological processes relevant to obstetrics and gynecology; however, there is a lack of understanding as to the precise role of oxidative stress in these processes. We aimed to develop a rapid, validated assay for the accurate quantification of 8-oxodG in human urine using solid-phase extraction and ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) and then investigate the levels of 8-oxodG in several fluids of interest to obstetrics and gynecology. Using UHPLC-MS/MS, 8-oxodG eluted after 3.94 min with an RSD for 15 injections of 0.07%. The method was linear between 0.95 and 95 nmol/L with LOD and LOQ of 5 and 25 fmol on-column, respectively. Accuracy and precision were 98.7-101.0 and <10%, respectively, over three concentrations of 8-oxodG. Recovery from urine was 88% with intra- and interday variations of 4.0 and 10.2%, respectively. LOQ from urine was 0.9 pmol/ml. Rank order from the greatest to lowest 8-oxodG concentration was urine>seminal plasma>amniotic fluid>plasma>serum>peritoneal fluid, and it was not detected in saliva. Urine concentrations normalized to creatinine (n=15) ranged between 0.55 and 1.95 pmol/µmol creatinine. We describe, for the first time, 8-oxodG concentrations in human seminal plasma, peritoneal fluid, amniotic fluid, and breast milk, as well as in urine, plasma, and serum, using a rapid UHPLC-MS/MS method that will further facilitate biomonitoring of oxidative stress.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Desoxiguanosina/análogos & derivados , Espectrometría de Masas en Tándem/métodos , 8-Hidroxi-2'-Desoxicoguanosina , Adulto , Líquido Amniótico/química , Líquido Ascítico/química , Biomarcadores/orina , ADN/química , ADN/metabolismo , Desoxiguanosina/análisis , Desoxiguanosina/sangre , Desoxiguanosina/orina , Femenino , Humanos , Masculino , Persona de Mediana Edad , Leche Humana/química , Estrés Oxidativo , Especies Reactivas de Oxígeno/metabolismo , Saliva/química , Semen/química , Sensibilidad y Especificidad , Extracción en Fase Sólida , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA