Resultados 1 - 8 de 8
Filtrar
1.
Sleep Breath ; 19(2): 637-44, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25335642

RESUMEN

PURPOSE: The objective of this randomized controlled trial was to assess the additional effect of a chest-worn sleep position trainer (SPT) in patients with residual supine-dependent obstructive sleep apnea (sdOSA) under mandibular advancement device (MAD) therapy. METHODS: Baseline and follow-up polysomnography with MAD were performed. Twenty patients with sdOSA under MAD therapy underwent two consecutive randomized polysomnographies: one with SPT and one with combination of SPT + MAD. Data are presented as median (quartile 1, quartile 3). RESULTS: The SPT reduced the time spent in supine sleeping position compared to baseline and MAD therapy. Both MAD and SPT were individually effective in reducing the overall apnea/hypopnea index (AHI) significantly when compared to baseline from 20.8 (15.1; 33.6)/h at baseline to 11.0 (6.7; 13.8)/h and to 11.1 (3.5; 17.7)/h with MAD or SPT, respectively. The combination of SPT + MAD further reduced the overall AHI to 5.7 (3.6; 7.4), which was significantly lower than with MAD alone (p < 0.001) and SPT alone (p < 0.008), respectively. CONCLUSIONS: The results of this study indicate that combination of SPT + MAD leads to a higher therapeutic efficacy in patients with sdOSA under MAD therapy when compared to one of the treatment modalities alone.


Asunto(s)
Terapia Combinada , Avance Mandibular/instrumentación , Ferulas Oclusales , Posicionamiento del Paciente/instrumentación , Modalidades de Fisioterapia/instrumentación , Apnea Obstructiva del Sueño/fisiopatología , Apnea Obstructiva del Sueño/terapia , Posición Supina/fisiología , Adulto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Polisomnografía
2.
Thorax ; 68(1): 91-6, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22993169

RESUMEN

BACKGROUND: Oral appliance (OA) therapy is increasingly prescribed as a non-continuous positive airway pressure treatment modality for sleep-disordered breathing (SDB). Although OA therapy is reported to be efficacious for the treatment of SDB, data on compliance remain limited to self-report. METHODS: In this 3-month prospective clinical trial, the main outcome was to assess the safety and feasibility of an objective measurement of compliance during OA therapy using an embedded microsensor thermometer with on-chip integrated readout electronics in 51 consecutive patients with an established diagnosis of SDB (AHI 18.0 ± 11.9/h; age 47 ± 10 y; BMI 26.6 ± 4.0 kg/m(2); men/women: 31/20). Patients were unaware of the purpose of the study. RESULTS: No microsensor-related adverse events were recorded. In addition, no problems were encountered during the readout of the compliance data. Out of 51 microsensors, one had a technical defect and was lost to follow-up. In this study, the overall objective mean rate of OA use was 6.6 ± 1.3 h per day with a regular OA users' rate of 82% at the 3-month follow-up. Statistical analysis revealed no significant differences between objective and self-reported OA compliance data in this study. Measurement of the objective OA compliance allowed us to calculate the mean disease alleviation (MDA) as the product of objective compliance and therapeutic efficacy. MDA serves as a measure of the overall therapeutic effectiveness, and turned out to be 51.1%. CONCLUSIONS: The results illustrate the safety and feasibility of objective measurement of OA compliance. The objective measurement of OA compliance allows for calculation of the MDA.


Asunto(s)
Sistemas Microelectromecánicos , Aparatos Ortodóncicos , Cooperación del Paciente/estadística & datos numéricos , Síndromes de la Apnea del Sueño/terapia , Adulto , Presión de las Vías Aéreas Positiva Contínua/métodos , Diseño de Equipo , Seguridad de Equipos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Polisomnografía/métodos , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Síndromes de la Apnea del Sueño/diagnóstico , Termómetros
3.
J Clin Sleep Med ; 18(3): 739-750, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-34608859

RESUMEN

STUDY OBJECTIVES: Mandibular advancement devices (MADs) are a noninvasive treatment option for patients with obstructive sleep apnea (OSA) and act by increasing the upper airway volume. However, the exact therapeutic mechanism of action remains unclear. The aim of this study was to assess MAD mechanisms using functional imaging that combines imaging techniques and computational fluid dynamics and assess associations with treatment outcome. METHODS: One hundred patients with OSA were prospectively included and treated with a custom-made MAD at a fixed 75% protrusion. A low-dose computed tomography scan was made with and without MADs for computational fluid dynamics analysis. Patients underwent a baseline and 3-month follow-up polysomnography to evaluate treatment efficacy. A reduction in apnea-hypopnea index ≥ 50% defined treatment response. RESULTS: Overall, 71 patients completed both 3-month follow-up polysomnography and low-dose computed tomography scan with computational fluid dynamics analysis. MAD treatment significantly reduced the apnea-hypopnea index (16.5 [10.4-23.6] events/h to 9.1 [3.9-16.4] events/h; P < .001, median [quartile 1-quartile 3]) and significantly increased the total upper airway volume (8.6 [5.4-12.8] cm3 vs 10.7 [6.4-15.4] cm3; P = .003), especially the velopharyngeal volume (2.1 [0.5-4.1] cm3 vs 3.3 [1.8-6.0] cm3; P < .001). However, subanalyses in responders and nonresponders only showed a significant increase in the total upper airway volume in responders, not in nonresponders. CONCLUSIONS: MAD acts by increasing the total upper airway volume, predominantly due to an increase in the velopharyngeal volume. Responders showed a significant increase in the total upper airway volume with MAD treatment, while there was no significant increase in nonresponders. Findings add evidence to implement functional imaging using computational fluid dynamics in routine MAD outcome prediction. CLINICAL TRIAL REGISTRATION: Registry: ClinicalTrials.gov; Name: Predicting Therapeutic Outcome of Mandibular Advancement Device Treatment in Obstructive Sleep Apnea; URL: https://clinicaltrials.gov/ct2/show/NCT01532050; Identifier: NCT01532050. CITATION: Van Gaver H, Op de Beeck S, Dieltjens M, et al. Functional imaging improves patient selection for mandibular advancement device treatment outcome in sleep-disordered breathing: a prospective study. J Clin Sleep Med. 2022;18(3):739-750.


Asunto(s)
Avance Mandibular , Apnea Obstructiva del Sueño , Humanos , Ferulas Oclusales , Selección de Paciente , Estudios Prospectivos , Apnea Obstructiva del Sueño/diagnóstico por imagen , Apnea Obstructiva del Sueño/terapia , Resultado del Tratamiento
5.
Am J Respir Crit Care Med ; 178(2): 197-202, 2008 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-17673699

RESUMEN

RATIONALE: The efficacy of immediate adaptation of mandibular advancement devices made of thermoplastic material as a treatment option for sleep-disordered breathing (SDB) has been demonstrated in clinical studies. To date, there have been no studies comparing the efficacy of such prefabricated devices with custom-made devices. OBJECTIVES: Our purpose was to compare the efficacy of both types of devices in patients with SDB. METHODS: A randomized controlled cross-over trial, comprising 4 months of treatment with a thermoplastic and a custom-made device, with a 1-month washout interval. MEASUREMENTS AND MAIN RESULTS: A total of 35 patients (29 males; age, 49 +/- 9 yr; apnea-hypopnea index [AHI], 13 +/- 11 events/h; body mass index, 28 +/- 4 kg/m(2)) completed the protocol. AHI was only reduced with the custom-made device (P = 0.005). In addition, this device reduced snoring to a greater extent than the thermoplastic device. The success rate was higher with the custom-made device (60 vs. 31%; P = 0.02). One-third of the patients demonstrated compliance failure with the thermoplastic device, mainly because of insufficient overnight retention. Total failure rate with the thermoplastic device was 69%, whereas the majority (63%) of these were successfully treated with the custom-made device. At the end of the study, 82% of the patients preferred the custom-made device, and 9% had no preference (P < 0.0001). CONCLUSIONS: In this study, a custom-made device turned out to be more effective than a thermoplastic device in the treatment of SDB. Our results suggest that the thermoplastic device cannot be recommended as a therapeutic option nor can it be used as a screening tool to find good candidates for mandibular advancement therapy.


Asunto(s)
Avance Mandibular/instrumentación , Aparatos Ortodóncicos Removibles , Apnea Obstructiva del Sueño/terapia , Ronquido/terapia , Análisis de Varianza , Estudios Cruzados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polisomnografía
6.
J Clin Sleep Med ; 15(8): 1089-1099, 2019 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-31482830

RESUMEN

STUDY OBJECTIVES: Mandibular advancement device (MAD) outcome varies between patients. We hypothesized that upper airway collapse sites, patterns, and degrees assessed during baseline drug-induced sleep endoscopy (DISE) affect MAD outcome. METHODS: One hundred patients with obstructive sleep apnea (OSA) were included and underwent baseline type 1 polysomnography. MAD was fitted intraorally at fixed 75% maximal protrusion. A total of 72 patients completed 3-month follow-up polysomnography and baseline DISE. Response was defined as apnea-hypopnea index (AHI) reduction ≥ 50%, deterioration as AHI increases during MAD treatment compared to baseline. RESULTS: Adjusting for baseline AHI and body mass index, patients with tongue base collapse showed 3.69 higher odds (1.27-10.73; P = .0128) for response. Complete concentric collapse at the level of the palate (5.32 [1.21-23.28]; P = .0234) and complete laterolateral oropharyngeal collapse (6.62 [1.14-38.34]; P = .0330) related to deterioration. Results for tongue base collapse and complete concentric collapse at the level of the palate were confirmed in the moderate to severe OSA subgroup. Applying these results to this selected subgroup increased response rate with 54% and decreased deterioration rate with 53%. These results were confirmed using other response and deterioration definitions. CONCLUSIONS: Three baseline DISE phenotypes identified during drug-induced sleep were significantly related to MAD treatment outcome: one beneficial, tongue base collapse, and two adverse, complete concentric collapse at the level of the palate and complete laterolateral oropharyngeal collapse. If confirmed in future prospective studies, these results could guide patient selection for MAD outcome. CLINICAL TRIAL REGISTRATION: This prospective clinical trial (PROMAD) was registered on Clinicaltrials.gov with identifier: NCT01532050. CITATION: Op de Beeck S, Dieltjens M, Verbruggen AE, Vroegop AV, Wouters K, Hamans E, Willemen M, Verbraecken J, De Backer WA, Van de Heyning PH, Braem MJ, Vanderveken OM. Phenotypic labelling using drug-induced sleep endoscopy improves patient selection for mandibular advancement device outcome: a prospective study. J Clin Sleep Med. 2019;15(8):1089-1099.


Asunto(s)
Endoscopía/métodos , Ferulas Oclusales , Apnea Obstructiva del Sueño/terapia , Femenino , Humanos , Hipnóticos y Sedantes/uso terapéutico , Masculino , Persona de Mediana Edad , Polisomnografía , Estudios Prospectivos , Apnea Obstructiva del Sueño/etiología , Apnea Obstructiva del Sueño/fisiopatología , Lengua/fisiopatología , Resultado del Tratamiento
7.
JAMA Otolaryngol Head Neck Surg ; 141(10): 894-900, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26402736

RESUMEN

IMPORTANCE: The main reported reasons for discontinuation of oral appliance therapy for sleep-disordered breathing (SDB) are the presence of self-perceived adverse effects and self-appreciated lack of efficacy. However, these conclusions rely only on subjective compliance data. OBJECTIVE: To determine which parameters are correlated with objectively measured data on compliance with oral appliance therapy. DESIGN, SETTING, AND PARTICIPANTS: For 51 outpatients with SDB, a prospective clinical trial using oral appliance therapy was conducted at Antwerp University Hospital from February 7, 2011, to October 8, 2013 (38 [75%] males; mean [SD] age, 49.3 [9.0] years; mean [SD] apnea-hypopnea index, 14.9 [9.3] events per hour of sleep; mean [SD] body mass index [calculated as weight in kilograms divided by height in meters squared], 26.3 [2.8]). Analysis was performed November 5, 2014. INTERVENTION: Oral appliance therapy with a custom-made, titratrable mandibular advancement device (OAm). MAIN OUTCOMES AND MEASURES: Possible correlations were assessed between objective compliance and patients' anthropometric characteristics, polysomnographic parameters, and answers to 3 subjective questionnaires (the visual analog scale for snoring, the Epworth Sleepiness Scale, and an adverse effects questionnaire). RESULTS: Median oral appliance use was 6.4 hours per night (range, 4.7-7.2 hours per night) at the 3-month follow-up. None of the anthropometric and polysomnographic parameters were correlated with compliance. No correlation was found between objective compliance and reports of excessive daytime sleepiness. However, a significant inverse correlation was found between objective compliance and posttreatment visual analog scale values for snoring (P = .006; ρ = ­.40). In addition, objective compliance was correlated significantly with a more pronounced decrease in socially disturbing snoring (P = .005; ρ = 0.39). The presence of dry mouth was the only adverse effect that was negatively correlated with objective compliance at the 3-month follow-up (P < .05; ρ = ­.31). CONCLUSIONS AND RELEVANCE: Neither the anthropometric and polysomnographic parameters nor reports of excessive daytime sleepiness correlated with compliance during oral appliance therapy. The 2 parameters that were correlated with higher objective compliance during oral appliance therapy were a more pronounced decrease in snoring and the presence of dry mouth during treatment. TRIAL REGISTRATION: clinicaltrials.gov Identifiers: NCT01284881 and NCT01532050.


Asunto(s)
Avance Mandibular/instrumentación , Cooperación del Paciente , Síndromes de la Apnea del Sueño/psicología , Síndromes de la Apnea del Sueño/terapia , Adulto , Femenino , Humanos , Masculino , Avance Mandibular/efectos adversos , Persona de Mediana Edad , Polisomnografía , Estudios Prospectivos , Encuestas y Cuestionarios , Factores de Tiempo , Resultado del Tratamiento
8.
Acta Otolaryngol ; 124(5): 628-33, 2004 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15267184

RESUMEN

OBJECTIVE: Mandibular advancement devices (MADs) have been introduced as a conservative, non-invasive treatment for socially disturbing snoring and mild obstructive sleep apnea (OSA). A prospective, non-randomized pilot study was conducted to investigate the efficacy, feasibility, side-effects and compliance of Somnoguard, an immediately intraorally adaptable MAD made from thermoplastic material. MATERIAL AND METHODS: Twenty consecutive heavy snorers with a respiratory disturbance index of <20 events/h were prospectively selected. Prior to the adaptation of the appliance, ambulatory polygraphy was carried out without a MAD. After a 1-month habituation period, a polygraphic evaluation was carried out with the device. Treatment success was defined as a reduction in the apnea-hypopnea index (AHI) of at least 50%. RESULTS: The results indicated a success rate of 65%. The AHI decreased from 8.4 +/- 2.9 events/h at baseline to 3.9 +/- 1.8 events/h with the device (p = 0.001). At 1-month follow-up, significant reductions in the snoring index (p < 0.001) and the Epworth Sleepiness Scale (ESS) score (p = 0.036) were noted. At 6-month follow-up, similar results were achieved, with significant drops in the snoring index (p = 0.025) and ESS score (p = 0.033). CONCLUSION: We conclude that immediate intraoral adaptation of a low-cost fabricated "one-size-only" MAD is a feasible and well-tolerated treatment for snoring and mild OSA. Further research is needed to evaluate this thermoplastic appliance as a strategy to "screen" the efficacy of MAD treatment in the individual patient with a less expensive appliance before constructing a more expensive custom-made MAD.


Asunto(s)
Avance Mandibular/instrumentación , Ronquido/terapia , Adulto , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Cooperación del Paciente , Satisfacción del Paciente , Proyectos Piloto , Plásticos , Polisomnografía , Estudios Prospectivos , Resultado del Tratamiento