Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Dent ; 145: 104939, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38521237

RESUMEN

OBJECTIVES: To measure the impact of superimposition methods and the designated comparison area on accuracy analyses of dentate models using an ISO-recommended 3-dimensional (3D) metrology-grade inspection software (Geomagic Control X; 3D Systems; Rock Hill, South Carolina; USA). MATERIALS AND METHODS: A dentate maxillary typodont scanned with a desktop scanner (E4; 3 Shape; Copenhagen; Denmark) and an intraoral scanner (Trios 4; 3 Shape; Copenhagen; Denmark) was used as reference. Eight groups were created based on the core features of each superimposition method: landmark-based alignment (G1); partial area-based alignment (G2); entire tooth area-based alignment (G3); double alignment combining landmark-based alignment with entire tooth area-based alignment (G4); double alignment combining partial area-based alignment with entire tooth area-based alignment (G5); initial automated quick pre-alignment (G6); initial automated precise pre-alignment (G7); and entire model area-based alignment (G8). Diverse variations of each alignment and two regions for accuracy analyses (teeth surface or full model surface) were tested, resulting in a total of thirty-two subgroups (n = 18). The alignment accuracy between experimental and reference meshes was quantified using root mean square (RMS) error as trueness and its repeatability as precision. The descriptive statistics, a factorial repeated measures analysis of variance (ANOVA) and a post hoc Tuckey multiple comparison tests were used to analyze the trueness, and precision (α = 0.05). RESULTS: A total of 576 superimpositions were performed. The unique partial area-based superimposition method demonstrated the least precise alignment and was the sole group to exhibit a significant difference (p<.001). Automated initial pre-alignments demonstrated similar accuracy to other superimposition methods (p>.05). Double alignments did not result in accuracy improvement (p>.05). The designated comparison area displayed differences in both trueness (p<.001) and precision (p<.001), leading to an overall discrepancy of 8 ± 4 µm between selecting the teeth surface or full model surface. CONCLUSIONS: The superimposition method choice within the tested software did not impact accuracy analyses, except when the alignment relies on a unique and reduced area, such as the palatal rugae, a single tooth, or three adjacent teeth on one side. CLINICAL SIGNIFICANCE: The superimposition method choice within the tested ISO-recommended 3D inspection software did not impact accuracy analyses.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Modelos Dentales , Programas Informáticos , Humanos , Imagenología Tridimensional/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Puntos Anatómicos de Referencia , Reproducibilidad de los Resultados , Maxilar/anatomía & histología , Diente/anatomía & histología , Diente/diagnóstico por imagen
2.
J Gastrointest Oncol ; 6(2): E16-20, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25830044

RESUMEN

Numb chin syndrome (NCS) can be a sign of malignancy. Its association with gastric adenocarcinoma is rare. We report a case of a 27-year-old Hispanic female that presented with complaint of left sided headache associated with numbness of the left side of chin and lower gingiva. Initial brain MRI, whole body gallium scan, high resolution CT of chest and elevated protein in the CSF were suggestive of sarcoidosis. She was treated with IV steroids with transient clinical improvement. Two weeks later, her symptoms worsened and further evaluation revealed the diagnosis of a poorly differentiated metastatic gastric adenocarcinoma with leptomeningeal involvement. This case report aims to emphasize the importance of identifying NCS as a possible indication of an underlying malignant condition. Reported cases of NCS associated with metastatic gastric adenocarcinoma are very rare.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA