Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Ann Vasc Surg ; 93: 275-282, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36796585

RESUMEN

BACKGROUND: The purpose of this trial was to assess the safety and effectiveness of a paclitaxel-coated balloon catheter in Chinese patients with de novo or nonstented restenotic femoropopliteal atherosclerotic lesions. METHODS: BIOLUX P-IV China is a prospective, independently adjudicated, multicenter, single-arm trial conducted in China. Patients with Rutherford class 2-4 were eligible, excluded were patients in which predilation resulted in severe (≥ grade D) flow-limiting dissection or residual stenosis > 70%. Follow-up assessments were conducted at 1, 6, and 12 months. The primary safety end point was 30-day major adverse event rate and the primary effectiveness end point was primary patency at 12 months. RESULTS: We enrolled 158 patients with 158 lesions. Mean age was 67.6 ± 9.6 years, diabetes was present in 53.8% (n = 85), and previous peripheral intervention/surgeries in 17.1% (n = 27). Lesions were 4.1 ± 0.9 mm in diameter and 74 ± 50 mm long with a mean diameter stenosis of 91 ± 13%; 58.2% (n = 92) were occluded (core laboratory analysis). Device success was achieved in all patients. The rate of major adverse events was 0.6% (95% confidence interval: 0.0; 3.5) at 30 days, consisting of 1 target lesion revascularization. At 12 months, binary restenosis was present in 18.7% (n = 26) and target lesion revascularization was performed in 1.4% (n = 2, all clinically driven), resulting in a primary patency of 80.0% (95% confidence interval: 72.4, 85.8); no major target limb amputation occurred. Clinical improvement at 12 months, defined as improvement of at least 1 Rutherford class, was 95.3% (n = 130). The median walking distance per 6-minute walk test was 279 m at baseline and improved by 50 m at 30 days and by 60 m at 12 months; the visual analogue scale changed from 76.6 ± 15.6 at baseline to 80.0 ± 15.0 at 30 days and 78.6 ± 14.6 at 12 months. CONCLUSIONS: Our results confirmed the clinical effectiveness and safety of a paclitaxel-coated peripheral balloon dilatation catheter for the treatment of de novo and nonstented restenotic lesion of the superficial femoral and proximal popliteal artery in Chinese patients (NCT02912715).


Asunto(s)
Angioplastia de Balón , Aterosclerosis , Enfermedad Arterial Periférica , Humanos , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Constricción Patológica/etiología , Resultado del Tratamiento , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Recuperación del Miembro , Arteria Femoral/diagnóstico por imagen , Aterosclerosis/etiología , Arteria Poplítea/diagnóstico por imagen , Paclitaxel/efectos adversos , China , Angioplastia de Balón/efectos adversos , Materiales Biocompatibles Revestidos , Catéteres , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA