Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Mater Sci Eng C Mater Biol Appl ; 109: 110522, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32228976

RESUMEN

Electrochemically reduced graphene oxide (ErGO) films on a biomedical grade CoCr alloy have been generated and characterized in order to study their possible application for use on joint prostheses. The electrodeposition process was performed by cyclic voltammetry. The characterization of the ErGO films on CoCr alloys by XPS revealed sp2 bonding and the presence of CO and CO residual groups in the graphene network. Biocompatibility studies were performed with mouse macrophages J774A.1 cell cultures measured by the ratio between lactate dehydrogenase and mitochondrial activities. An enhancement in the biocompatibility of the CoCr with the ErGO films was obtained, a result that became more evident as exposure time increased. Macrophages on the CoCr with the ErGO were well-distributed and conserved the characteristic cell shape. In addition, vimentin expression was unaltered in comparison with the control, results that indicated an improvement in the CoCr biocompatibility with the ErGO on the material surface. The in vivo response of graphene and graphene oxide was assessed by intraperitoneal injection in wistar rats. Red blood cells are one of the primary interaction sites so hemocompatibility tests were carried out. Rats inoculated with graphene and graphene oxide showed red blood cells of smaller size with a high content in hemoglobin.


Asunto(s)
Aleaciones de Cromo , Materiales Biocompatibles Revestidos , Técnicas Electroquímicas , Grafito , Macrófagos/metabolismo , Ensayo de Materiales , Animales , Aleaciones de Cromo/química , Aleaciones de Cromo/farmacología , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Grafito/química , Grafito/farmacología , Masculino , Ratones , Oxidación-Reducción , Ratas , Ratas Wistar
2.
Bioelectrochemistry ; 115: 1-10, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28126645

RESUMEN

The interaction of the physiological medium and living tissues with the implant surfaces in biological environments is regulated by biopotentials that induce changes in the chemical composition, structure and thickness of the oxide film. In this work, oxide films grown on CoCr alloys at 0.5 V vs Ag/AgCl and 0.7 V vs Ag/AgCl have been characterized through overall and localized electrochemical techniques in a phosphate buffer solution and 0.3% hyaluronic acid. Nanopores of 10-50nm diameter are homogeneously distributed along the surface in the oxide film formed at 0.7 V vs Ag/AgCl. The distribution of the Constant Phase Element studied by local electrochemical impedance spectroscopy showed a three-dimensional (3D) model on the oxide films grown at 0.5 V vs Ag/AgCl and 0.7 V vs Ag/AgCl. This behaviour is especially noticeable in oxide films grown at 0.7 V vs Ag/AgCl, probably due to surface inhomogeneities, and resistive properties generated by the potentiostatic growth of the oxide film.


Asunto(s)
Aleaciones/química , Electroquímica/métodos , Materiales Biocompatibles/química , Aleaciones de Cromo/química , Cobalto/química , Corrosión , Espectroscopía Dieléctrica , Ácido Hialurónico/química , Ensayo de Materiales/métodos , Microscopía Electrónica de Rastreo , Óxidos/química , Prótesis e Implantes , Compuestos de Plata/química , Soluciones/química , Propiedades de Superficie
3.
J Biomed Mater Res A ; 77(2): 220-9, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16392123

RESUMEN

Thermal oxidation treatments of Ti6Al4V, at 500 and 700 degrees C, for 1 h result in the formation of an outer "ceramic" layer of rutile, which enhances osteoblast response. In the present study, we have measured in vitro Ti and Al ion release from Ti64 alloy in the as-received state and after thermal oxidation treatments at 500 or 700 degrees C, to culture medium under standard cell-culture conditions. Concentrations of both Ti and Al released from both thermal oxidation treatments were lower than from polished alloy. Al was released from the treated or untreated surfaces in substantially lower extent than Ti. Titanium and aluminium ions affected primary human osteoblast proliferation, metabolic activity, and differentiation in a dose-dependent manner. Treatments with individual Ti or Al metal ions in similar concentration ranges than released from the surfaces did not alter osteoblast response, which also remained unaffected after treatments with combinations of Ti plus Al applied in the proportional relations than detected in ion-release experiments. We then selected higher concentrations of Ti that impaired osteoblast proliferation and differentiation, while the proportional lower concentrations of Al did not alter osteoblast behavior. In spite of its inert character, it was found that Al significantly enhanced the deleterious effect of Ti on osteoblast differentiation. Therefore, thermal oxidation treatments of Ti6Al4V alloy may improve the biocompatibility of the alloy by reducing both Ti and Al release, and thus attenuating ion-mediated interference with osteoblast differentiation.


Asunto(s)
Aluminio/metabolismo , Osteoblastos/metabolismo , Titanio/metabolismo , Anciano , Aleaciones , Aluminio/química , Animales , Materiales Biocompatibles/química , Materiales Biocompatibles/metabolismo , Biomarcadores/metabolismo , Diferenciación Celular , Proliferación Celular , Células Cultivadas , Humanos , Iones/química , Iones/metabolismo , Ensayo de Materiales , Osteoblastos/citología , Soluciones/química , Titanio/química
4.
Biomed Mater ; 10(4): 045015, 2015 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-26238295

RESUMEN

AZ31 alloy has been tested as a biodegradable material in the form of endomedullary implants in female Wistar rat femurs. In order to evaluate the accumulation of potentially toxic elements from the biodegradation of the implant, magnesium (Mg), aluminium (Al), zinc (Zn), manganese (Mn) and fluorine (F) levels have been measured in different organs such as kidneys, liver, lungs, spleen and brain. Several factors that may influence accumulation have been taken into account: how long the implant has been in place, whether or not the bone is fractured, and the presence of an MgF2 protective coating on the implant. The main conclusions and the clinical relevance of the study have been that AZ31 endomedullary implants have a degradation rate of about 60% after 13 months, which is fully compatible with fracture consolidation. Neither bone fracture nor an MgF2 coating seems to influence the accumulation of trace elements in the studied organs. Aluminium is the only alloying element in this study that requires special attention. The increase in Al recovered from the sampled organs represents 3.95% of the amount contained in the AZ31 implant. Al accumulates in a statistically significant way in all the organs except the brain. All of this suggests that in long-term tests AZ31 may be a suitable material for osteosynthesis.


Asunto(s)
Implantes Absorbibles , Aleaciones/química , Sustitutos de Huesos/química , Fémur/química , Metales/análisis , Prótesis e Implantes , Animales , Corrosión , Difusión , Análisis de Falla de Equipo , Fémur/cirugía , Estudios Longitudinales , Ensayo de Materiales , Especificidad de Órganos , Diseño de Prótesis , Ratas , Ratas Wistar
5.
Biomed Mater ; 10(2): 025008, 2015 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-25886380

RESUMEN

The ideal temporary implant should offer enough mechanical support to allow healing of the fracture and then biodegrade and be resorbed by metabolic mechanisms without causing any toxic effect. The aim of this research has been to simultaneously study in situ bone healing and the biodegradation of AZ31 Mg alloy as an osteosynthesis material. The in vivo study was carried out in AZ31 implants with and without Mg-fluoride coating inserted in un-fractured and fractured femurs of Wistar rats for long experimentation time, from 1 to 13 months, by means of computed tomography, histological and histomorphometric analysis. Tomography analysis showed the bone healing and biodegradation of AZ31 implants. The fracture is healed in 100% of the animals, and AZ31 maintains its mechanical integrity throughout the healing process. Biodegradation was monitored, quantifying the evolution of gas over time by 3D composition of tomography images. In all the studied groups, gas pockets disappear with time as a result of the diffusion process through soft tissues. Histomorphometric studies reveal that after 13 months the 46.32% of AZ31 alloy has been resorbed. The resorption of the coated and uncoated AZ31 implants inserted in fractured femurs after 1, 9 and 13 months does not have statistically significant differences. There is a balance between the biodegradation of AZ31 and bone healing which allows the use of AZ31 to be proposed as an osteosynthesis material.


Asunto(s)
Implantes Absorbibles , Aleaciones , Materiales Biocompatibles , Fracturas del Fémur/cirugía , Curación de Fractura , Aleaciones/química , Animales , Materiales Biocompatibles/química , Fenómenos Biomecánicos , Materiales Biocompatibles Revestidos/química , Corrosión , Femenino , Fracturas del Fémur/diagnóstico por imagen , Fluoruros/química , Fijación Intramedular de Fracturas , Compuestos de Magnesio/química , Ensayo de Materiales , Ratas , Ratas Wistar , Factores de Tiempo , Tomografía Computarizada por Rayos X
6.
Biomaterials ; 15(14): 1175-80, 1994 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-7893921

RESUMEN

The need for appropriated metallic materials for long-term implants is nowadays the driving force for the development of alternative materials with improved corrosion resistance in body fluids. In this work the in vitro corrosion behaviour of MA 956 is evaluated by means of electrochemical techniques during long-term tests in simulated human body media. This alloy, after an isothermal treatment at 1100 degrees C, develops on the surface a fine, dense and adherent alpha-alumina scale which considerably enhances the good corrosion resistance of the non-treated alloy.


Asunto(s)
Aleaciones/efectos adversos , Aluminio/efectos adversos , Materiales Biocompatibles/efectos adversos , Cromo/efectos adversos , Hierro/efectos adversos , Titanio/efectos adversos , Itrio/efectos adversos , Aleaciones/química , Aluminio/química , Materiales Biocompatibles/química , Cromo/química , Corrosión , Electroquímica , Microanálisis por Sonda Electrónica , Técnicas In Vitro , Hierro/química , Oxidación-Reducción , Óxidos/química , Prótesis e Implantes/efectos adversos , Titanio/química , Itrio/química
7.
Biomaterials ; 7(3): 197-200, 1986 May.
Artículo en Inglés | MEDLINE | ID: mdl-3719038

RESUMEN

An experimental method has been developed for in vivo measurement of electrical parameters. It is thus possible to evaluate not only the instantaneous corrosion rate of implants but also their susceptibility to pitting corrosion. It has also been shown that when the method is applied to stainless steel/ceramic electrodes, these remain in the passive condition. If an eventual breakdown of the passivating film occurs, it will quickly regenerate itself.


Asunto(s)
Electrodos Implantados , Óxido de Aluminio , Animales , Materiales Biocompatibles , Corrosión , Perros , Electroquímica , Electrónica Médica , Técnicas In Vitro , Acero Inoxidable
8.
Biomaterials ; 16(9): 735-40, 1995 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-7578779

RESUMEN

Preoxidation treatment of MA 956 superalloy at 1100 degrees C produces a fine and tightly adherent alpha-alumina layer at the surface, which provides the alloy with an excellent barrier against a great variety of aggressive environments. In this work the protective capacity of the alumina/alloy system is evaluated in a physiological medium by means of electrochemical impedance spectroscopy. The electrochemical response of the material is modelled by equivalent circuits which provide the most relevant corrosion and protection parameters applicable to MA 956 in both preoxidized and as-received conditions (passivated state). The high protective capacity of preoxidized MA 956 superalloy holds for long-term tests, which indicates that the corrosion phenomena, if any, would be characterized by very slow kinetics. The corrosion resistance of the preoxidized material is at least two orders of magnitude higher than that of the non-treated alloy.


Asunto(s)
Aluminio/química , Materiales Biocompatibles/química , Cromo/química , Hierro/química , Titanio/química , Itrio/química , Aleaciones/química , Óxido de Aluminio/química , Impedancia Eléctrica , Electroquímica/métodos , Calefacción , Oxidación-Reducción , Análisis Espectral/métodos
9.
Biomaterials ; 21(1): 79-87, 2000 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-10619681

RESUMEN

This paper presents the influence of substrate roughness on the corrosion behaviour of the Al2O3/MA 956 system. An alumina layer of thickness 1-5 microm was generated of the MA956 alloy by thermal oxidation at 1100 degrees C using different exposure times. This Al2O3/MA 956 system with a polished substrate has shown excellent corrosion behaviour in a physiological fluid, due to the fact that the alpha-Al2O3 layer formed is dense, continuous and firmly adhered to the substrate, irrespective of the scale thickness. This good adherence allows it to withstand potentials above 1.7 V. Specimens with rough finish substrate and treatment times above 10 h present spallation of the alumina layer at the crests of the roughness profile. In this case a mixed corrosion behaviour between an alumina coated material and one with a passive layer is observed. In both types of specimens, rough and smooth, once the passivation layer is broken the repassivation capacity of the substrate is ensured due to the high chromium content of the alloy, under oxygenation conditions.


Asunto(s)
Aleaciones/química , Óxido de Aluminio/química , Aluminio/química , Materiales Biocompatibles/química , Cromo/química , Materiales Biocompatibles Revestidos/química , Hierro/química , Titanio/química , Itrio/química , Corrosión , Conductividad Eléctrica , Impedancia Eléctrica , Calor , Microscopía Electrónica de Rastreo , Oxidación-Reducción , Propiedades de Superficie
10.
Biomaterials ; 22(8): 755-62, 2001 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11246943

RESUMEN

The influence of two different sizes of polyethylene particles (< 30 and 20-200 microm) on osteoblastic function has been studied in primary human bone cell cultures. Cells were obtained from trabecular bone fragments of patients undergoing knee reconstructive surgery. On reaching confluency, cells were subcultured in three flasks: < 30 microm polyethylene particles were added to the first flask, 20-200 microm particles to the second flask and none to the third flask, which was the control. The resulting subcultures were incubated until confluence. Osteoblastic function was evaluated by assaying the secretion of osteocalcin, alkaline phosphatase, and C-terminal type I procollagen (PICP), with or without 1.25(OH)2D3 stimulation in the cell-conditioned medium. Adding < 30 microm polyethylene particles to these osteoblastic cell cultures increased the levels of osteocalcin secreted after 1,25(OH)2D3 stimulation. Treating stimulated or basal osteoblastic cultures with either polyethylene particle size did not affect alkaline phosphatase secretion. However, the addition of <30 microm polyethylene particles decreased PICP levels in the basal and stimulated cultures. A parallel series of osteoblastic cultures was treated with < 30 microm polyethylene particles and stimulated or not with 1,25(OH)2D3 to determine the effect on osteocalcin mRNA expression using RT-PCR amplification. Polyethylene particle-treated cultures had higher osteocalcin mRNA expression regardless of whether they had been stimulated with 1,25(OH)2D3 or not. We conclude that particle size affects the influence of polyethylene on osteoblastic function markers. Particles with a diameter of less than 30 microm increase osteocalcin expression and secretion.


Asunto(s)
Materiales Biocompatibles/toxicidad , Osteoblastos/efectos de los fármacos , Osteoblastos/fisiología , Polietileno/toxicidad , Fosfatasa Alcalina/metabolismo , Materiales Biocompatibles/química , Calcitriol/farmacología , Células Cultivadas , Medios de Cultivo Condicionados , Reacción a Cuerpo Extraño/etiología , Expresión Génica/efectos de los fármacos , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Osteoblastos/citología , Osteocalcina/genética , Osteocalcina/metabolismo , Tamaño de la Partícula , Fragmentos de Péptidos/metabolismo , Polietileno/química , Procolágeno/metabolismo , Falla de Prótesis , ARN Mensajero/genética , ARN Mensajero/metabolismo
11.
Mater Sci Eng C Mater Biol Appl ; 41: 127-33, 2014 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-24907745

RESUMEN

In this paper, two complementary approaches, mathematical modeling and experimental results are combined to identify variables that affect the in vivo biodegradation of magnesium implants. The in vivo corrosion behavior of AZ31 alloy proposed for temporary applications as fixation of bone fractures has been modeled solving the Laplace equation by finite element method (FEM). Bar-shaped AZ31 implants of 1mm diameter and 20mm length were inserted in Wistar rat femurs with and without a fracture. The presence of gas around AZ31 implants inside the femurs has been detected in situ at the epiphysis and in fractured areas by computerized tomography (CT). Examining some in vivo conditions, the model confirms that magnesium-alloy devices have different biodegradation behavior, depending on the thickness of electrolyte at the implantation site and can be used for predicting the biodegradation behavior.


Asunto(s)
Implantes Absorbibles/veterinaria , Aleaciones/química , Modelos Teóricos , Aleaciones/uso terapéutico , Animales , Corrosión , Electrólitos/química , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/terapia , Fémur/diagnóstico por imagen , Ratas , Ratas Wistar , Tomografía Computarizada por Rayos X
12.
Acta Biomater ; 7(6): 2716-25, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21382529

RESUMEN

The long-term interfacial bond between an implant and bone may be improved by creating a rough surface on the implant in order to increase the surface area available for bone/implant apposition. A natural consequence of surface roughening is an increase in metal ion release, which is itself a surface dominated process. Based on this fact, the aim of this work is to study the influence of the microstructure and topography on the barrier properties of oxide scales thermally generated at 700 °C for 1h on Ti6Al4V surfaces after blasting with Al(2)O(3) particles (coarse) or SiO(2) and ZrO(2) particles (fine). The microstructural and topographical characterization of the thermally treated blasted surfaces has been studied by means of scanning electron microscopy coupled with energy dispersive X-ray analysis, contact profilometry and X-ray diffraction. The barrier properties and corrosion behaviour of the oxide layers have been studied by means of electrochemical impedance spectroscopy (EIS) in Hank's solution. Thermal treatment at 700 °C for 1h promotes the formation of oxide scales with different morphologies and crystalline structures depending on the degree of deformation of the blasted surface. The oxide scale grown on the finely blasted sample has a pine needle-like morphology which is mainly formed of anatase TiO(2). In contrast, the oxide scale grown on the coarsely blasted sample has a globular morphology formed mainly of rutile TiO(2). The differences in morphology, i.e. fine or coarse, of the oxide scales influence the corrosion response of the blasted thermally treated samples in Hank's solution. The EIS results permit evaluation of the different oxide scales from the capacitance and resistance values obtained in the high-frequency region and show a good correlation between the morphology and barrier properties. Oxidation treatment at 700 °C for 1h of Ti6Al4V samples coarsely blasted with Al(2)O(3) improves the corrosion behaviour due to an increase in the thickness of a compact, ordered and more structurally stable oxide scale. This is due to the globular morphology of the rutile (TiO(2)) structure maintaining an average surface roughness suitable for optimal osseo-integration with long-term interfacial bonding between the implant and bone.


Asunto(s)
Óxidos/química , Titanio/química , Aleaciones , Microscopía Electrónica de Rastreo , Análisis Espectral/métodos , Propiedades de Superficie , Difracción de Rayos X
13.
Acta Biomater ; 6(5): 1763-71, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-19446048

RESUMEN

The corrosion behaviour of AZ31 magnesium alloy with different grain sizes immersed in simulated body fluids was compared in chloride solution (8 gl(-1)) and in phosphate-buffer solution (PBS). The influence of immersion time was also analyzed. Electrochemical techniques such as open circuit potential, polarization curves, transient currents and electrochemical impedance spectroscopy, complemented with scanning electron microscopy and energy dispersive spectroscopy, were used. Immediately after the immersion in the corrosive media the corrosion resistance was similar for both grain sizes of the AZ31 alloy and higher in NaCl solutions than in PBS. However, this corrosion behaviour was reversed after longer periods of immersion due to the stabilizing of the corrosion products of MgO by P-containing compounds. These P-compounds contribute to a higher level of protection by hindering the aggressive action of chloride ions. The best corrosion behaviour of the AZ31 alloy was obtained for the finest grain alloy associated with the highest transfer resistance value, after long periods of immersion in PBS.


Asunto(s)
Aleaciones/química , Líquidos Corporales/química , Magnesio/química , Tamaño de la Partícula , Corrosión , Impedancia Eléctrica , Electricidad , Cinética , Potenciometría , Soluciones , Espectroscopía Infrarroja por Transformada de Fourier , Factores de Tiempo
14.
J Biomed Mater Res ; 31(3): 313-7, 1996 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-8806056

RESUMEN

In this work the corrosion behavior of a new biomaterial, the MA-956 superalloy, immersed in Hank's solution is evaluated. A comparison with conventional metallic alloys used as articular implants is established. To determine the corrosion behavior we employed electrochemical methods: evaluation of corrosion potential Ecorr, electrochemical impedance spectroscopy (EIS), and anodic polarization curves. The corrosion resistance of the MA-956 superalloy preoxidized at 1100 degrees C during 100 h is at least two orders of magnitude higher than for the other alloys. This satisfactory behavior is stationary with time. Also the probability of the appearance of the pitting corrosion process is very low. When cracking is generated in the alpha-alumina layer the repassivation process is assured because of the high Cr content in the superalloy. This study is the first step in proposing this new alloy as a biomaterial. The low toxicity of these metallic alloys in the physiological environment suggests that in vivo their biocompatibility could be satisfactory.


Asunto(s)
Aleaciones/química , Aluminio/química , Materiales Biocompatibles/química , Cromo/química , Hierro/química , Titanio/química , Itrio/química , Corrosión , Electroquímica , Concentración de Iones de Hidrógeno , Oxidación-Reducción , Propiedades de Superficie , Factores de Tiempo
15.
J Biomed Mater Res ; 46(2): 179-85, 1999 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-10379995

RESUMEN

An experimental study of the oxidation treatment at high temperature of the ODS MA956 superalloy was conducted in an attempt to achieve a protective alumina scale for biomedical applications. A quadratic response-surface model was developed in order to study the effects of treatment time and temperature (in the range of 1000 degrees C to 1250 degrees C) on scale thickness. The obtained model adequately represents the experimental response and shows that the thickness gradients of the layer increase with the temperature for each exposure time and decrease steadily to zero as the treatment time increases. The microstructural characterization reveals that the alumina scale formed at or above 1000 degrees C consists of an alpha-alumina phase. Treatments at temperatures above 1150 degrees C give rise to an alumina scale with some defect probability. An increase in the temperature up to 1200 degrees C gives rise to the appearance of some blistering of the superficial scale. An oxidation treatment of 100 h at 1100 degrees C was found to be the best for guaranteeing the formation of a defect-free, compact, adherent, and continuous alpha-alumina scale thick enough to support satisfactory wear and biological conditions.


Asunto(s)
Aleaciones , Óxido de Aluminio , Aluminio , Cromo , Materiales Biocompatibles Revestidos , Hierro , Titanio , Itrio , Corrosión , Microanálisis por Sonda Electrónica , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Temperatura , Factores de Tiempo , Difracción de Rayos X
16.
J Biomed Mater Res ; 54(1): 30-6, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11077400

RESUMEN

One of the problems associated with the modern biomaterials used in prostheses is osteolysis, which, although its exact origin is unknown, has been associated with wear particles. Osteoblasts seem to participate directly in this phenomenon. This paper investigates in vitro cellular response to the wear particles from the metal substrate and ceramic covering (alpha-alumina) of a new titanium yttrium aluminum alloy, MA 956, that has been proposed as a biomaterial because of its exceptional mechanical and electrochemical properties. The effect of different sizes (10 and 80 microm) of MA 956 and alpha-alumina particles on osteoblast function was studied in primary human bone cell cultures. Cells were harvested from trabecular bone fragments obtained during knee arthroplasty. Osteoblastic cell response to the particles was measured by assaying C-terminal type I procollagen (PICP), alkaline phosphatase, and osteocalcin secretion, with and without 1.25(OH)(2)D(3) stimulation, in the cell-conditioned medium. Both sizes of MA 956 and alpha-alumina particles decreased PICP secretion in nonstimulated osteoblastic cells, but this secretion was not affected in the cultures stimulated with 1.25(OH)(2)D(3). Only the 10 microm alpha-alumina particles inhibited alkaline phosphatase activity in 1.25(OH)(2)D(3)-stimulated and nonstimulated cultures. The rise in osteocalcin levels after 1.25(OH)(2)D(3) stimulation was lower in the presence of the 10 microm MA 956 particles than in the presence of alpha-alumina particles. Although both materials seem to have directly affected in vitro osteoblastic cell function, the increase in osteocalcin levels after 1.25(OH)(2)D(3) stimulation was lower after exposure to MA 956 particles than the increase observed after exposure to alpha-alumina particles. Therefore, it does not seem that osteocalcin stimulated bone resorption, suggesting that MA 956 would be less likely to provoke osteolysis.


Asunto(s)
Aleaciones/farmacología , Óxido de Aluminio/farmacología , Aluminio/farmacología , Materiales Biocompatibles , Cromo/farmacología , Hierro/farmacología , Osteoblastos/efectos de los fármacos , Titanio/farmacología , Itrio/farmacología , Anciano , Fosfatasa Alcalina/metabolismo , Células Cultivadas , Cerámica/farmacología , Medios de Cultivo Condicionados , Humanos , Ensayo de Materiales , Osteocalcina/metabolismo , Tamaño de la Partícula , Procolágeno/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA