Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Molecules ; 27(19)2022 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-36234898

RESUMEN

Due to the decreasing self-repairing ability, elder people are easier to form chronic wounds and suffer from slow and difficult wound healing. It is desirable to develop a novel wound dressing that can accelerate chronic wound healing in elderly subjects to decrease the pain of patients and save medical resources. In this work, Heparin and basic fibroblast growth factor(bFGF) were dissolved in the mixing solution of 4-arm acrylated polyethylene glycol and dithiothreitol to form hydrogel dressing in vitro at room temperature without any catalysts, which is convenient and easy to handle in clinic application. In vitro re-lease test shows the bFGF could be continuously released for at least 7 days, whereas the dressing surface integrity maintained for 3 days degradation in PBS solution. Three groups of treatments including bFGF-Gel, bFGF-Sol and control without any treatment were applied on the full-thickness wound on the 22 months old mice back. The wound closure rate and histological and immunohistochemical staining all illustrated that bFGF-Gel displayed a better wound healing effect than the other two groups. Thus, as-prepared hydrogel dressing seems supe-rior to current clinical treatment and more effective in elderly subjects, which shows promising potential to be applied in the clinic.


Asunto(s)
Factor 2 de Crecimiento de Fibroblastos , Hidrogeles , Animales , Vendajes , Modelos Animales de Enfermedad , Ditiotreitol/farmacología , Factor 2 de Crecimiento de Fibroblastos/farmacología , Heparina/farmacología , Hidrogeles/farmacología , Ratones , Polietilenglicoles/farmacología , Cicatrización de Heridas
2.
J Mater Sci Mater Med ; 31(8): 76, 2020 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-32761269

RESUMEN

Vascular grafts prepared from synthetic polymers have serious shortcomings that can be resolved by surface modification, such as by immobilizing heparin. In this study, the mechanical properties, biocompatibility, anticoagulation property, and water contact angle of two heparin-conjugated poly(ε-caprolactone) scaffolds (PCL-hexamethylendiamine-heparin, PCL-HMD-H. PCL-lysine-heparin, PCL-LYS-H) were compared to identify a preferred heparin conjugation method. An evaluation of the subcutaneous tissue biocompatibility of the scaffolds demonstrated that PCL-HMD-H had better endothelial cell proliferation than the PCL-LYS-H and was therefore a promising scaffold candidate for use in vascular tissue-engineering.


Asunto(s)
Heparina/química , Poliésteres/química , Tejido Subcutáneo/efectos de los fármacos , Andamios del Tejido , Animales , Prótesis Vascular/efectos adversos , Adhesión Celular/efectos de los fármacos , Movimiento Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Células Cultivadas , Heparina/farmacología , Células Endoteliales de la Vena Umbilical Humana , Humanos , Masculino , Ensayo de Materiales , Modelos Animales , Poliésteres/farmacología , Polímeros/química , Polímeros/farmacología , Implantación de Prótesis/métodos , Ratas , Ratas Wistar , Ingeniería de Tejidos/métodos , Andamios del Tejido/efectos adversos , Andamios del Tejido/química
3.
J Vasc Res ; 55(6): 338-349, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30485863

RESUMEN

In the field of vascular graft research, poly-ε-caprolactone (PCL) is used owing to its good mechanical strength and biocompatibility. In this study, PCL scaffold was prepared by electrospinning and surface modification with heparin via hexamethylenediamine. Then the scaffolds were implanted into the infrarenal abdominal aorta of Wistar rats and contrast-enhanced micro-ultrasound was used to monitor the patency of grafts after implantation. These grafts were extracted from the rats at 1, 3, and 6 months for histological analysis, immunofluorescence staining, and scanning electron microscopy observation. Although some grafts experienced aneurysmal change, results showed that all implanted grafts were patent during the course of 6 months and these grafts demonstrated well-organized neotissue with endothelium formation, smooth muscle regeneration, and extracellular matrix formation. Such findings confirm feasibility to create heparin-conjugated scaffolds of next-generation vascular grafts.


Asunto(s)
Aorta Abdominal/cirugía , Heparina/química , Poliésteres/química , Andamios del Tejido/química , Remodelación Vascular , Animales , Anticoagulantes , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/ultraestructura , Materiales Biocompatibles , Prótesis Vascular , Endotelio Vascular/fisiología , Matriz Extracelular/fisiología , Microscopía Electrónica de Rastreo , Modelos Animales , Músculo Liso Vascular/fisiología , Ratas , Ratas Wistar , Regeneración , Ultrasonografía , Injerto Vascular/métodos
4.
J Mater Sci Mater Med ; 26(2): 112, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25665848

RESUMEN

Studies on three-dimensional tissue engineered graft (3DTEG) have attracted great interest among researchers as they present a means to meet the pressing clinical demand for tissue engineering scaffolds. To explore the feasibility of 3DTEG, high porosity poly-ε-caprolactone (PCL) was obtained via the co-electrospinning of polyethylene glycol and PCL, and used to construct small-diameter poly-ε-caprolactone-lysine (PCL-LYS-H) scaffolds, whereby heparin was anchored to the scaffold surface by lysine groups. A variety of small-diameter 3DTEG models were constructed with different PCL layers and the mechanical properties of the resulting constructs were evaluated in order to select the best model for 3DTEGs. Bone marrow mononuclear cells were induced and differentiated to endothelial cells (ECs) and smooth muscle cells (SMCs). A 3DTEG (labeled '10-4%') was successfully produced by the dynamic co-culture of ECs on the PCL-LYS-H scaffolds and SMCs on PCL. The fluorescently labeled cells on the 3DTEG were subsequently observed by laser confocal microscopy, which showed that the ECs and SMCs were embedded in the 3DTEG. Nitric oxide and endothelial nitric oxide synthase assays showed that the ECs behaved normally in the 3DTEG. This study consequently provides a new thread to produce small-diameter tissue engineered grafts, with excellent mechanical properties, that are perfusable to vasculature and functional cells.


Asunto(s)
Células Endoteliales/citología , Leucocitos Mononucleares/citología , Miocitos del Músculo Liso/citología , Poliésteres/química , Ingeniería de Tejidos/instrumentación , Andamios del Tejido , Animales , Materiales Biocompatibles/síntesis química , Diferenciación Celular/fisiología , Proliferación Celular/fisiología , Supervivencia Celular/fisiología , Células Cultivadas , Fuerza Compresiva , Perros , Módulo de Elasticidad , Galvanoplastia/métodos , Células Endoteliales/fisiología , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Factibilidad , Leucocitos Mononucleares/fisiología , Ensayo de Materiales , Miocitos del Músculo Liso/fisiología , Estrés Mecánico , Propiedades de Superficie , Resistencia a la Tracción
5.
Int J Biol Macromol ; 277(Pt 3): 134509, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39111508

RESUMEN

Aiming to improve the retrieval rate of retrievable vena cava filters (RVCF) and extend its dwelling time in vivo, a novel hydrogel coating loaded with 10 mg/mL heparin and 30 mg/mL cyclodextrin/paclitaxel (PTX) inclusion complex (IC) was prepared. The drug-release behavior in the phosphate buffer solution demonstrated both heparin and PTX could be sustainably released over approximately two weeks. Furthermore, it was shown that the hydrogel-coated RVCF (HRVCF) with 10 mg/mL heparin and 30 mg/mL PTX IC effectively extended the blood clotting time to above the detection limit and inhibited EA.hy926 and CCC-SMC-1 cells' proliferation in vitro compared to the commercially available bare RVCF. Both the HRVCF and the bare RVCF were implanted into the vena cava of sheep and retrieved at at 2nd and 4th week after implantation, revealing that the HRVCF had a significantly higher retrieval rate of 67 % than the bare RVCF (0 %) at 4th week. Comprehensive analyses, including histological, immunohistological, and immunofluorescent assessments of the explanted veins demonstrated the HRVCF exhibited anti-hyperplasia and anticoagulation properties in vivo, attributable to the hydrogel coating, thereby improving the retrieval rate in sheep. Consequently, the as-prepared HRVCF shows promising potential for clinical application to enhance the retrieval rates of RVCFs.


Asunto(s)
Ciclodextrinas , Heparina , Hidrogeles , Paclitaxel , Filtros de Vena Cava , Ciclodextrinas/química , Ciclodextrinas/farmacología , Paclitaxel/farmacología , Paclitaxel/química , Heparina/química , Heparina/farmacología , Animales , Hidrogeles/química , Hidrogeles/farmacología , Humanos , Ovinos , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Coagulación Sanguínea/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Liberación de Fármacos
6.
Biomater Adv ; 165: 214018, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-39226677

RESUMEN

A high vascular patency was realized in the bulk or surface heparinized small-diameter in situ tissue-engineered vascular grafts (TEVGs) via a rabbit carotid artery replacement model in our previous studies. Those surface heparinized TEVGs could reduce the occurrence of aneurysms, but with a low level of the remodeled elastin, whereas those bulk heparinized TEVGs displayed a faster degradation and an increasing occurrence of aneurysms, but with a high level of the regenerated elastin. To combine the advantages of the bulk and surface graft heparinization to boost the remodeling of elastin and defer the occurrence of aneurysms, a coaxial electro-spinning technique was used to fabricate a kind of small-diameter core/shell fibrous structural in situ TEVGs with a faster degradable poly(lactic-co-glycolic acid) (PLGA) as a core layer and a relatively lower degradable poly(ε-caprolactone) (PCL) as a shell layer followed by the surface heparinization. The in vitro mechanical performance and enzymatic degradation tests revealed the resulting PLGA@PCL-Hep in situ TEVGs possessing not only a faster degradation rate, but also the mechanical properties comparable to those of human saphenous veins. After implanted in the rat abdominal aorta for 12 months, the good endothelialization, low inflammation, and no calcification were evidenced. Furthermore, the neointima layer of regenerated new blood vessels was basically constructed with a well-organized arrangement of elastin and collagen proteins. The results showed the great potential of these in situ TEVGs to be used as a novel type of long-term small-diameter vascular grafts.


Asunto(s)
Prótesis Vascular , Ingeniería de Tejidos , Animales , Ratas , Ingeniería de Tejidos/métodos , Copolímero de Ácido Poliláctico-Ácido Poliglicólico/química , Poliésteres/química , Aorta Abdominal/patología , Implantación de Prótesis Vascular/métodos , Elastina/metabolismo , Masculino , Andamios del Tejido/química , Ratas Sprague-Dawley , Humanos , Conejos , Ensayo de Materiales
7.
Biomed Mater ; 19(3)2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38430567

RESUMEN

In our previous study, the pristine bilayer small-diameterin situtissue engineered vascular grafts (pTEVGs) were electrospun from a heparinized polycaprolactone (PCL45k) as an inner layer and a non-heparinized PCL80k as an outer layer in the thickness of about 131 µm and 202 µm, respectively. However, the hydrophilic enhancement of inner layer stemmed from the heparinization accelerated the degradation of grafts leading to the early formation of arterial aneurysms in a period of 3 months, severely hindering the perennial observation of the neo-tissue regeneration, host cell infiltration and graft remodeling in those implanted pTEVGs. Herein to address this drawback, the thickness of the outer layers was increased with PCL80k to around 268 µm, while the inner layer remained unchangeable. The thickened TEVGs named as tTEVGs were evaluated in six rabbits via a carotid artery interpositional model for a period of 9 months. All the animals kept alive and the grafts remained patent until explantation except for one whose one side of arterial blood vessels was occluded after an aneurysm occurred at 6 months. Although a significant degradation was observed in the implanted grafts at 9 month, the occurrence of aneurysms was obviously delayed compared to pTEVGs. The tissue stainings indicated that the endothelial cell remodeling was substantially completed by 3 months, while the regeneration of elastin and collagen remained smaller and unevenly distributed in comparison to autologous vessels. Additionally, the proliferation of macrophages and smooth muscle cells reached the maximum by 3 months. These tTEVGs possessing a heparinized inner layer and a thickened outer layer exhibited good patency and significantly delayed onset time of aneurysms.


Asunto(s)
Aneurisma , Poliésteres , Ingeniería de Tejidos , Animales , Conejos , Prótesis Vascular , Arterias Carótidas
8.
Int J Biol Macromol ; 267(Pt 2): 131667, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38636761

RESUMEN

A thiolated RGD was incorporated into the threaded allyl-ß-cyclodextrins (Allyl-ß-CDs) of the polyrotaxane (PR) through a thiol-ene click reaction, resulting in the formation of dynamic RGD ligands on the PR surface (dRGD-PR). When maintaining consistent RGD density and other physical properties, endothelial cells (ECs) cultured on dRGD-PR exhibited significantly increased cell proliferation and a larger cell spreading area compared to those on the non-dynamic RGD (nRGD-PCL). Furthermore, ECs on dRGD-PR demonstrated elevated expression levels of FAK, p-FAK, and p-AKT, along with a larger population of cells in the G2/M stage during cell cycle analysis, in contrast to cells on nRGD-PCL. These findings suggest that the movement of the RGD ligands may exert additional beneficial effects in promoting EC spreading and proliferation, beyond their essential adhesion and proliferation-promoting capabilities, possibly mediated by the RGD-integrin-FAK-AKT pathway. Moreover, in vitro vasculogenesis tests were conducted using two methods, revealing that ECs cultured on dRGD-PR exhibited much better vasculogenesis than nRGD-PCL in vitro. In vivo testing further demonstrated an increased presence of CD31-positive tissues on dRGD-PR. In conclusion, the enhanced EC spreading and proliferation resulting from the dynamic RGD ligands may contribute to improved in vitro vasculogenesis and in vivo vascularization.


Asunto(s)
Proliferación Celular , Ciclodextrinas , Oligopéptidos , Humanos , Adhesión Celular/efectos de los fármacos , Movimiento Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Ciclodextrinas/química , Ciclodextrinas/farmacología , Células Endoteliales/metabolismo , Células Endoteliales/efectos de los fármacos , Células Endoteliales/citología , Células Endoteliales de la Vena Umbilical Humana/metabolismo , Células Endoteliales de la Vena Umbilical Humana/efectos de los fármacos , Ligandos , Neovascularización Fisiológica/efectos de los fármacos , Oligopéptidos/farmacología , Oligopéptidos/química , Poloxámero/química , Poloxámero/farmacología , Proteínas Proto-Oncogénicas c-akt/metabolismo , Rotaxanos
9.
ACS Appl Bio Mater ; 6(12): 5252-5263, 2023 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-37955977

RESUMEN

The surface modification of biologically active factors on tissue-engineering vascular scaffold fails to fulfill the mechanical property and bioactive compounds' sustained release in vivo and results in the inhibition of tissue regeneration of small-diameter vascular grafts in vascular replacement therapies. In this study, biodegradable poly(ε-caprolactone) (PCL) was applied for scaffold preparation, and poly(ethylene glycol) (PG) hydrogel was used to load heparin and hepatocyte growth factor (HGF). In vitro analysis demonstrated that the PCL scaffold could inhibit the heparin release from the PG hydrogel, and the PG hydrogel could inhibit heparin release during the process of PCL degradation. Finally, it results in sustained release of HGF and heparin from the PCL-PG-HGF scaffold. The mechanical property of this hybrid scaffold improved after being coated with the PG hydrogel. In addition, the PCL-PG-HGF scaffold illustrated no inflammatory lesions, organ damage, or biological toxicity in all primary organs, with rapid organization of the endothelial cell layer, smooth muscle regeneration, and extracellular matrix formation. These results indicated that the PCL-PG-HGF scaffold is biocompatible and provides a microenvironment in which a tissue-engineered vascular graft with anticoagulant properties allows regeneration of vascular tissue (Scheme 1). Such findings confirm the feasibility of creating hydrogel scaffolds coated with bioactive factors to prepare novel vascular grafts.


Asunto(s)
Materiales Biocompatibles , Factor de Crecimiento de Hepatocito , Factor de Crecimiento de Hepatocito/farmacología , Preparaciones de Acción Retardada/farmacología , Materiales Biocompatibles/farmacología , Polietilenglicoles/farmacología , Hidrogeles/farmacología , Heparina/farmacología
10.
Macromol Rapid Commun ; 33(13): 1143-8, 2012 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-22492506

RESUMEN

A polypseudorotaxane (PPR) comprising γ-cyclodextrin (γ-CD) as host molecules and poly(N-isopropylacrylamide) (PNIPAM) as a guest polymer is prepared via self-assembly in aqueous solution. Due to the bulky pendant isopropylamide group, PNIPAM exhibits size-selectivity toward self-assembly with α-, ß-, and γ-CDs. It can fit into the cavity of γ-CD to give rise to a PPR, but cannot pass through α-CD and ß-CD under the same conditions. The ratio of the number of γ-CD molecules to entrapped NIPAM repeat units is kept at 1:2.2 or 1:2.4, determined by (1) H NMR spectroscopy and TGA analysis, respectively, indicating that there are more than 2 but less than 3 NIPAM repeat units included by one γ-CD molecule. This finding opens new avenues to PPR-based supramolecular polymers to be used as solid, stimuli-responsive materials.


Asunto(s)
Acrilamidas/química , Polímeros/síntesis química , Rotaxanos/química , gamma-Ciclodextrinas/química , Resinas Acrílicas , Estructura Molecular , Polimerizacion , Polímeros/química , beta-Ciclodextrinas/química
11.
Biomater Adv ; 133: 112628, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35527159

RESUMEN

Increasingly growing problems in vascular access for long-term hemodialysis lead to a considerable demand for synthetic small diameter vascular prostheses, which usually suffer from some drawbacks and are associated to high failure rates. Incorporating the concept of in situ tissue engineering (TE) into synthetic small diameter blood vessels, for example, thermoplastic poly(ether urethane) (TPU) ones, could provide an alternative approach for vascular access that profits from the advantages of excellent mechanical properties of synthetic polymer materials (early cannulation) and unique biointegration regeneration of autologous neovascular tissues (long-term fistulae). In this study, a kind of heparinized small diameter (d = 2.5 mm) TPU/poly(ε-caprolactone) (TPU/PCL-Hep) bi-layered blood vessels was electrospun with an inner layer of PCL and an outer layer of TPU. Afterward, the inner surface heparinization was conducted by coupling H2N-PEG-NH2 to the corroded PCL layer and then heparin to the attached H2N-PEG-NH2 via the EDCI/NHS chemistry. Herein a heparinized PCL inner layer could not only inhibit thrombosis, but also provide sufficient space for the neotissue regeneration via biodegradation with time. Meanwhile, a TPU outer layer could confer the vascular access the good mechanical properties, such as flexibility, viability and fitness of elasticity between the grafts and host blood vessels as evidenced by the adequate mechanical properties, such as compliance (4.43 ± 0.07%/ 100 mmHg), burst pressure (1447 ± 127 mmHg) and suture retention strength (1.26 ± 0.07 N) without blood seepage after implantation. Furthermore, a rabbit carotid aortic replacement model for 5 months was demonstrated 100% animal survival and 86% graft patency. Puncture assay also revealed the puncture resistance and self-sealing (hemostatic time < 2 min). Histological analysis highlighted neotissue regeneration, host cell infiltration and graft remodeling in terms of extracellular matrix turnover. Altogether, these results showed promising aspects of small diameter TPU/PCL-Hep bi-layered grafts for hemodialytic vascular access applications.


Asunto(s)
Sustitutos Sanguíneos , Andamios del Tejido , Animales , Arterias Carótidas/cirugía , Poliésteres/química , Conejos , Ingeniería de Tejidos/métodos , Andamios del Tejido/química
12.
Biomater Sci ; 10(15): 4257-4270, 2022 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-35766246

RESUMEN

As thermoplastic polyurethane (TPU) elastomers possess good biocompatibility and mechanical properties similar to those of native vascular tissues, they were intended to be co-electrospun with poly(ε-caprolactone) (PCL) onto the outer surface of PCL electrospun small-diameter single-layer vascular grafts (SLVGs) in this study, combining with surface heparinization. In this work, a kind of structurally reinforced TPU+PCL/PCL small-diameter bilayer vascular graft (BLVG) was fabricated via layer-by-layer electrospinning followed by the heparinization of PCL via EDC/NHS chemistry. The resulting (TPU+PCL/PCL)-Hep BLVGs presented excellent mechanical strength and higher compliance, and sustainably released heparin exhibited enhanced anti-coagulation activity. During 6-month implantation in 18 rat abdominal aortas, these vascular prostheses induced the remodeling and regeneration of neovascular tissues, and promoted ECM deposition. Compared to heparinized PCL (PCL-Hep) SLVGs, the formation of aneurysm was completely inhibited and the onset of calcification was significantly delayed in (TPU+PCL/PCL)-Hep BLVGs. Not only vascular cell makers co-expressed by CD206+ cells were identified, but also a high content of elastin was evidenced due to the improvement of mechanical strength and compliance. These results indicated the feasibility and efficacy of inhibiting the aneurysm formation and boosting the vascular remodeling by incorporating TPU into PCL-Hep small-diameter artificial vascular grafts.


Asunto(s)
Prótesis Vascular , Poliuretanos , Animales , Aorta Abdominal/cirugía , Poliésteres/química , Poliuretanos/química , Ratas , Andamios del Tejido/química
13.
Biomater Adv ; 142: 213138, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36219919

RESUMEN

Tissue engineering is thought to the most promising strategy to develop successful small diameter vascular grafts (SDVG) to meet clinical demand. The introduction of natural substances into the SDVG made from synthetic biomaterials can improve the biocompatibility to promote the regeneration of SDVG in vivo. Due to that natural materials from different sources may have property deviation, it is vital to determine the source of natural materials to optimize SDVG fabrication for tissue engineering applications. In this study, bioactive SDVGs were prepared via coating of heparin-modified poly-(ε-caprolactone) scaffolds with a precursor solution containing vascular extracellular matrix (VECM) components and subsequent in situ gelation. The mechanical properties, degradation behaviors, and morphologies of the SDVGs were thoroughly characterized and evaluated. Cell experiments demonstrated the in vitro tissue specificity of the VECM that could promote the proliferation of endothelial cells better than skin-derived collagen. Furthermore, three types of SDVGs, SDVGs with blank hydrogel, SDVGs with skin-derived collagen, and SDVGs with vascular extracellular matrix (VECM-SDVGs), were implanted into the abdominal aorta of rats for one month. The explanted SDVGs were then comprehensively evaluated using hematoxylin and eosin, Masson, von Kossa staining, and immunohistochemical staining for CD31, α-SMA, and MHC. The results showed that the VECM-SDVGs showed the best endothelium regeneration, appropriate intima regeneration, and no calcification, indicating the in vivo specificity of the fabricated VECM-SDVGs. Thus, long-term implantation of VECM-SDVGs was performed. The results showed that a complete endothelial layer formed after 6 months of implantation, and the amount of contractile SMCs in the regenerative smooth muscle layer approached the amount of native aorta at the 12th month. Consequently, relying on vascular tissue specificity, VECM-SDVGs can modulate the regenerative behavior of the implanted SDVGs in vivo to achieve satisfactory vascular regeneration both in short- and long-term implantation.


Asunto(s)
Hidrogeles , Ingeniería de Tejidos , Ratas , Animales , Ingeniería de Tejidos/métodos , Células Endoteliales , Poliésteres/química , Matriz Extracelular , Colágeno
14.
J Biomed Mater Res A ; 109(12): 2493-2505, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34096176

RESUMEN

Long-term in vivo observation in large animal model is critical for evaluating the potential of small diameter tissue engineering vascular graft (SDTEVG) in clinical application, but is rarely reported. In this study, a SDTEVG is fabricated by the electrospinning of poly(ε-caprolactone) and subsequent heparin modification. SDTEVG is implanted into canine's abdominal aorta for 511 days in order to investigate its clinical feasibility. An active and robust remodeling process was characterized by a confluent endothelium, macrophage infiltrate, extracellular matrix deposition and remodeling on the explanted graft. The immunohistochemical and immunofluorescence analysis further exhibit the regeneration of endothelium and smooth muscle layer on tunica intima and tunica media, respectively. Thus, long-term follow-up reveals viable neovessel formation beyond graft degradation. Furthermore, the von Kossa staining exhibits no occurrence of calcification. However, although no TEVG failure or rupture happens during the follow-up, the aneurysm is found by both Doppler ultrasonic and gross observation. Consequently, as-prepared TEVG shows promising potential in vascular tissue engineering if it can be appropriately strengthened to prevent the occurrence of aneurysm.


Asunto(s)
Prótesis Vascular , Vasos Sanguíneos/trasplante , Heparina/química , Poliésteres/química , Aneurisma/prevención & control , Animales , Aorta Abdominal/trasplante , Perros , Endotelio Vascular/crecimiento & desarrollo , Matriz Extracelular/ultraestructura , Humanos , Macrófagos , Músculo Liso Vascular/crecimiento & desarrollo , Proyectos Piloto , Andamios del Tejido , Túnica Íntima , Túnica Media
15.
J Biomater Sci Polym Ed ; 32(9): 1161-1181, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33830866

RESUMEN

Rapid endothelialization is crucial for in situ tissue engineering vascular grafts to prevent graft failure in the long-term. Gelatin is a promising nature material that can promote endothelial cells (ECs) adhesion, proliferation, and migration. In this study, the internal surface of electrospun polycaprolactone (PCL) vascular grafts was coated with gelatin. Endothelialization and vascular wall remolding were investigated by imaging and histological studies in the rat abdominal aorta replacement model. The endothelialization of heparinized gelatin-coated PCL (GP-H) vascular grafts was more rapid and complete than heparinized PCL (P-H) grafts. Intimal hyperplasia was milder in the GP-H vascular grafts than the P-H vascular grafts in the long-term. Meanwhile, smooth muscle cells (SMCs) and extracellular matrix (ECM) regeneration were better in the GP-H vascular grafts. By comparison, an aneurysm was observed in the P-H group in 6 months. Calcification was observed in both groups. All vascular grafts were patient after implantation in both groups. Our results showed that gelatin coating on the internal surface of PCL grafts is a simple and effective way to promote endothelialization. A more rapid endothelialization and complete endothelium can inhibit intimal hyperplasia in the long-term.


Asunto(s)
Células Endoteliales , Gelatina , Animales , Prótesis Vascular , Humanos , Poliésteres , Ratas
16.
Bioengineered ; 12(1): 5769-5788, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34519254

RESUMEN

Substitution or bypass is the most effective treatment for vascular occlusive diseases.The demand for artificial blood vessels has seen an unprecedented rise due to the limited supply of autologous blood vessels. Tissue engineering is the best approach to provide artificial blood vessels. In this study, a new type of small-diameter artificial blood vessel with good mechanical and biological properties was designed by using electrospinning coaxial fibers. Four groups of coaxial fibers vascular membranes having polyurethane/gelatin core-shell structure were cross-linked by the EDC-NHS system and characterized. The core-shell structure of the coaxial vascular fibers was observed by transmission electron microscope. After the crosslinking, the stress and elastic modulus increased and the elongation decreased, burst pressure of 0.11 group reached the maximum (2844.55 ± 272.65 mmHg) after cross-linking, which acted as the experimental group. Masson staining identified blue-stained ring or elliptical gelatin ingredients in the vascular wall. The cell number in the vascular wall of the coaxial group was found in muscle embedding experiment significantly higher than that of the non-coaxial group at all time points(p < 0.001). Our results showed that the coaxial vascular graft with the ratio of 0.2:0.11 had better mechanical properties (burst pressure reached 2844.55 ± 272.65 mmHg); Meanwhile its biological properties were also outstanding, which was beneficial to cell entry and offered good vascular remodeling performance.Polyurethane (PU); Gelatin (Gel); Polycaprolactone (PCL); polylactic acid (PLA);1-(3-Dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC); N-Hydroxy succinimide (NHS); 4-Morpholine-ethane-sulfonic (MES); phosphate buffered saline (PBS); fetal calf serum (FCS); Minimum Essential Medium (MEM); Dimethyl sulfoxide (DMSO); hematoxylin-eosin (HE).


Asunto(s)
Prótesis Vascular , Gelatina/química , Poliuretanos/química , Remodelación Vascular/fisiología , Animales , Línea Celular , Técnicas Electroquímicas , Ensayo de Materiales , Fenómenos Mecánicos , Ratones , Ratas , Ratas Wistar
17.
ACS Appl Bio Mater ; 4(3): 2373-2384, 2021 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-35014358

RESUMEN

Hydrogel complex scaffolds (hydrogel scaffolds) are prepared by coating precursor solutions onto heparin-modified poly(ε-caprolactone) (PCLH) scaffolds followed by subsequent in situ gelation. Here, we show that hydrogel complexation can significantly strengthen the scaffold and slow its degradation. The hydrogel scaffold was implanted into the abdominal aorta of a rat model, and the aneurysm incidence rate of the hydrogel scaffolds sharply decreased compared with that of the hydrogel-free scaffolds. Histological and immunohistological analyses showed that the implanted grafts had good vascular regeneration. The absence of calcification and occurrence of contractile smooth muscle cells (SMCs) at the first month was found in the hydrogel-free PCLH scaffold due to the presence of surface-modified heparin, whereas the hydrogel scaffold exhibited mild calcification and later occurrence of contractile SMCs as the complexed hydrogel covered the fibers and blocked the interaction between heparin and cells. Heparin was further physically encapsulated into the hydrogel before gelation, and its sustainable release was demonstrated by an in vitro release test. A pilot implantation in a rabbit carotid model showed that the encapsulated heparin modulated the scaffold characteristics including anticoagulation, anticalcification, and the early occurrence of contractile SMCs in vivo. Consequently, hydrogel complexation can significantly improve the in vivo regeneration property of the scaffold due to its multiple beneficial characteristics.


Asunto(s)
Aorta Abdominal/efectos de los fármacos , Materiales Biocompatibles/farmacología , Hidrogeles/farmacología , Miocitos del Músculo Liso/efectos de los fármacos , Ingeniería de Tejidos , Animales , Aorta Abdominal/patología , Materiales Biocompatibles/síntesis química , Materiales Biocompatibles/química , Femenino , Hidrogeles/síntesis química , Hidrogeles/química , Masculino , Ensayo de Materiales , Miocitos del Músculo Liso/patología , Tamaño de la Partícula , Ratas , Ratas Wistar , Andamios del Tejido/química
18.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 27(6): 1274-9, 2010 Dec.
Artículo en Zh | MEDLINE | ID: mdl-21374978

RESUMEN

A novel diisocyanate, i. e. lysine ethyl ester diisocyanate (LDI), was prepared by the present authors. Poly (epsilon-caprolactone) (PCL) (M(n) = 2000) was used for reacting with LDI to form prepolymer, and then the chain was extended with butanediol (BDO) to form polyurethane (PU). PU was characterized by gel permeation chromatography, FTIR and 1H-NMR. Mechanical properties test revealed that PU possesses excellent tensile strength. Hydrolytic degradation and enzymatic degradation of PU films showed that PU is biodegradable. Finally, vascular scaffold of PU was fabricated by electrospinning. Morphological and biomechanical properties of scaffold were examined. The tensile strength was 8MPa, suture retention strength 12N, porosity 75% and burst pressure strength 150-170 kPa. Cytotoxicity and cell adhesion showed that PU scaffolds are biocompatible. These results demonstrate that PU vascular scaffolds possess excellent physical strength and biocompatibility and can be developed as substitutes for native blood vessels.


Asunto(s)
Materiales Biocompatibles , Isocianatos/química , Lisina/análogos & derivados , Poliésteres/química , Poliuretanos/síntesis química , Andamios del Tejido , Materiales Biocompatibles/síntesis química , Materiales Biocompatibles/química , Prótesis Vascular , Lisina/química , Poliuretanos/química , Ingeniería de Tejidos/métodos
19.
J Biomater Sci Polym Ed ; 31(8): 999-1023, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32138617

RESUMEN

Decellularization is a promising approach in tissue engineering to generate small-diameter blood vessels. However, some challenges still exist. We performed two decellularization phases to develop an optimal decellularized scaffold and analyze the relationship between the extracellular matrix (ECM) composition and mechanical properties. In decellularization phase I, we tested sodium dodecylsulfate (SDS), Triton X-100 (TX100) and trypsin at different concentrations and exposure times. In decellularization phase II, we systematically compared five combined decellularization protocols based on the results of phase I to identify the optimal method. These protocols tested cell removal, ECM preservation, mechanical properties, and residual cytotoxicity. We further immobilized heparin to optimal decellularized scaffolds and determined its anticoagulant activity and mechanical properties. The combined decellularization protocol comprising treatment with 0.5% SDS followed by 1% TX100 could completely remove the cellular contents and preserve the mechanical properties and ECM architecture better. In addition, the heparinized decellularized scaffolds not only had sustained anticoagulant activity, but also similar mechanical properties to native vessels. In conclusion, heparinized decellularized scaffolds represent a promising direction for small-diameter vascular grafts, although further in vivo studies are needed.


Asunto(s)
Heparina/metabolismo , Fenómenos Mecánicos , Andamios del Tejido/química , Animales , Matriz Extracelular/metabolismo , Octoxinol/química , Dodecil Sulfato de Sodio/química , Tripsina/química
20.
Macromol Biosci ; 19(8): e1900114, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31222914

RESUMEN

Aiming to construct small diameter (ID <6 mm) off-the-shelf tissue-engineered vascular grafts, the end-group heparinizd poly(ε-caprolactone) (PCL) is synthesized by a three-step process and then electrospun into an inner layer of double-layer vascular scaffolds (DLVSs) showing a hierarchical double distribution of nano- and microfibers. Afterward, PCL without the end-group heparinization is electrospun into an outer layer. A steady release of grafted heparin and the existence of a glycocalyx structure give the grafts anticoagulation activity and the conjugation of heparin also improves hydrophilicity and accelerates degradation of the scaffolds. The DLVSs are evaluated in six rabbits via a carotid artery interpositional model for a period of three months. All the grafts are patent until explantation, and meanwhile smooth endothelialization and fine revascularization are observed in the grafts. The composition of the outer layer of scaffolds exhibits a significant effect on the aneurysm dilation after implantation. Only one aneurysm dilation is detected at two months and no calcification is formed in the follow-up term. How to prevent aneurysms remains a challenging topic.


Asunto(s)
Implantes Absorbibles , Prótesis Vascular , Heparina/farmacología , Neovascularización Fisiológica , Poliésteres/química , Ingeniería de Tejidos/métodos , Animales , Arterias Carótidas/cirugía , Proliferación Celular/efectos de los fármacos , Técnicas Electroquímicas , Células Endoteliales/citología , Células Endoteliales/efectos de los fármacos , Células Endoteliales/fisiología , Heparina/química , Nanofibras/química , Conejos , Andamios del Tejido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA