Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Environ Sci Technol ; 51(8): 4585-4595, 2017 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-28318247

RESUMEN

Herein, we study the feasibility of using nanocellulose (NC)-based composites with silver and platinum nanoparticles as additive materials to fabricate the support layer of thin film composite (TFC) membranes for water purification applications. In brief, the NC surface was chemically modified and then was decorated with silver and platinum nanoparticles, respectively, by chemical reduction. These metalized nanocellulose composites (MNC) were characterized by several techniques including: FTIR, XPS, TGA, XRD, and XANES to probe their integrity. Thereafter, we fabricated the MNC-TFC membranes and the support layer was modified to improve the membrane properties. The membranes were thoroughly characterized, and the performance was evaluated in forward osmosis (FO) mode with various feed solutions: nanopure water, urea, and wastewater samples. The fabricated membranes exhibited finger-like pore morphologies and varying pore sizes. Interestingly, higher water fluxes and solute rejection was obtained with the MNC-TFC membranes with wastewater samples. The overall approach of this work provides an effort to fabricated membranes with high water flux and enhanced selectivity.


Asunto(s)
Membranas Artificiales , Purificación del Agua , Ósmosis , Soluciones , Aguas Residuales/química
2.
J Digit Imaging ; 28(1): 41-52, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25005868

RESUMEN

This article summarizes the consensus reached at the Summit on Color in Medical Imaging held at the Food and Drug Administration (FDA) on May 8-9, 2013, co-sponsored by the FDA and ICC (International Color Consortium). The purpose of the meeting was to gather information on how color is currently handled by medical imaging systems to identify areas where there is a need for improvement, to define objective requirements, and to facilitate consensus development of best practices. Participants were asked to identify areas of concern and unmet needs. This summary documents the topics that were discussed at the meeting and recommendations that were made by the participants. Key areas identified where improvements in color would provide immediate tangible benefits were those of digital microscopy, telemedicine, medical photography (particularly ophthalmic and dental photography), and display calibration. Work in these and other related areas has been started within several professional groups, including the creation of the ICC Medical Imaging Working Group.


Asunto(s)
Color/normas , Diagnóstico por Imagen/normas , Humanos , Estándares de Referencia , Estados Unidos , United States Food and Drug Administration
3.
J Occup Environ Hyg ; 7(11): 607-15, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20845207

RESUMEN

Studies of exposure to the lung carcinogen hexavalent chromium (CrVI) from welding tasks are limited, especially within the construction industry where overexposure may be common. In addition, despite the OSHA requirement that the use of engineering controls such as local exhaust ventilation (LEV) first be considered before relying on other strategies to reduce worker exposure to CrVI, data on the effectiveness of LEV to reduce CrVI exposures from welding are lacking. The goal of the present study was to characterize breathing zone air concentrations of CrVI during welding tasks and primary contributing factors in four datasets: (1) OSHA compliance data; (2) a publicly available database from The Welding Institute (TWI); (3) field survey data of construction welders collected by the Center for Construction Research and Training (CPWR); and (4) controlled welding trials conducted by CPWR to assess the effectiveness of a portable LEV unit to reduce CrVI exposure. In the OSHA (n = 181) and TWI (n = 124) datasets, which included very few samples from the construction industry, the OSHA permissible exposure level (PEL) for CrVI (5 µg/m(3)) was exceeded in 9% and 13% of samples, respectively. CrVI concentrations measured in the CPWR field surveys (n = 43) were considerably higher, and 25% of samples exceeded the PEL. In the TWI and CPWR datasets, base metal, welding process, and LEV use were important predictors of CrVI concentrations. Only weak-to-moderate correlations were found between total particulate matter and CrVI, suggesting that total particulate matter concentrations are not a good surrogate for CrVI exposure in retrospective studies. Finally, in the controlled welding trials, LEV reduced median CrVI concentrations by 68% (p = 0.02). In conclusion, overexposure to CrVI in stainless steel welding is likely widespread, especially in certain operations such as shielded metal arc welding, which is commonly used in construction. However, exposure could be substantially reduced with proper use of LEV.


Asunto(s)
Contaminantes Ocupacionales del Aire , Cromo , Exposición Profesional/prevención & control , Exposición Profesional/estadística & datos numéricos , Soldadura/estadística & datos numéricos , Materiales de Construcción , Bases de Datos Factuales , Humanos , Exposición Profesional/normas , Material Particulado , Acero Inoxidable , Soldadura/métodos
4.
Med Phys ; 36(7): 2898-914, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19673189

RESUMEN

Digital radiographic imaging systems, such as those using photostimulable storage phosphor, amorphous selenium, amorphous silicon, CCD, and MOSFET technology, can produce adequate image quality over a much broader range of exposure levels than that of screen/film imaging systems. In screen/film imaging, the final image brightness and contrast are indicative of over- and underexposure. In digital imaging, brightness and contrast are often determined entirely by digital postprocessing of the acquired image data. Overexposure and underexposures are not readily recognizable. As a result, patient dose has a tendency to gradually increase over time after a department converts from screen/film-based imaging to digital radiographic imaging. The purpose of this report is to recommend a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The intent is to facilitate the production of consistent, high quality digital radiographic images at acceptable patient doses. This should be based not on image optical density or brightness but on feedback regarding the detector exposure provided and actively monitored by the imaging system. A standard beam calibration condition is recommended that is based on RQA5 but uses filtration materials that are commonly available and simple to use. Recommendations on clinical implementation of the indices to control image quality and patient dose are derived from historical tolerance limits and presented as guidelines.


Asunto(s)
Monitoreo de Radiación , Intensificación de Imagen Radiográfica , Aluminio , Animales , Automatización , Calibración , Simulación por Computador , Cobre , Retroalimentación , Humanos , Mamografía/instrumentación , Mamografía/métodos , Mamografía/veterinaria , Fotones , Dosis de Radiación , Monitoreo de Radiación/instrumentación , Monitoreo de Radiación/métodos , Intensificación de Imagen Radiográfica/instrumentación , Intensificación de Imagen Radiográfica/métodos , Radiografía Dental/instrumentación , Radiografía Dental/métodos , Radiografía Dental/veterinaria , Radiografía Torácica/instrumentación , Radiografía Torácica/métodos , Radiografía Torácica/veterinaria , Análisis Espectral , Rayos X
10.
Environ Sci Technol ; 40(23): 7381-6, 2006 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-17180992

RESUMEN

Growing demands for potable water have strained water resources and increased interest in wastewater reclamation for potable reuse. This interest has brought increased attention to endocrine-disrupting chemicals (EDCs) as emerging water contaminants. The effect of EDCs, and in particular natural steroid hormones, on humans is of heightened interest in the study of wastewater reuse in advanced life support systems (e.g., space missions) because they are excreted in urine and have high endocrine-disrupting potencies. Direct contact membrane distillation (DCMD) and forward osmosis (FO) are being investigated for wastewater treatment in space. Retention of two natural steroid hormones, estrone and 17beta-estradiol, by these two processes was evaluated in the current investigation. DCMD provided greater than 99.5% hormone rejection; DCMD also provided constant flux, greater than 99.9% urea and ammonia rejection, and high water recovery. FO provided from 77 to 99% hormone rejection depending on experiment duration and feed solution chemistry.


Asunto(s)
Disruptores Endocrinos/análisis , Hormonas Esteroides Gonadales/análisis , Membranas Artificiales , Eliminación de Residuos Líquidos/métodos , Contaminantes Químicos del Agua/análisis , Purificación del Agua/métodos , Ósmosis
11.
Ann Occup Hyg ; 49(2): 179-93, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15734830

RESUMEN

Computational fluid dynamics (CFD) and numerical investigations of particle inhalability and contaminant exposure have used simple geometrical surrogates for a breathing human form, but the effect of eliminating facial features has not been investigated. In this work, the velocity field and particle aspiration associated with two differently shaped mannequins were investigated to determine if an elliptical form was sufficient to represent the complexity of fluid flow associated with an inhaling human. Laser Doppler anemometry was used to measure velocity, and both optical sizing and gravimetric analysis were used to measure particle aspiration from an aerosol source. All tests were performed with continuous inhalation through the mouth, with the mannequin facing the 0.3 m s(-1) freestream. Although limitations in the laser Doppler optics prevented velocity measurements at distances <11 mm in front of the mannequin mouth opening, significant velocity differences were identified up to 20 mm in front of the mouth opening. This indicated that facial features affected the flow field near the face only. Owing to these differences, particle aspiration was compared between mannequins for three different velocity ratio conditions using an aerosol source. Even with relatively large variability in the aspirated concentration in this study, the aspirated mass concentration was significantly less for the anatomical mannequin relative to the elliptical form. Thus, the simplified elliptical cylinder does not sufficiently characterize the fluid dynamics near the mouth of an inhaling human form at these limited test conditions. Future CFD and numerical simulations to investigate human aspiration of particles should incorporate the complex features of the human face to investigate adequately particle aspiration in low velocity environments.


Asunto(s)
Simulación por Computador , Cara/anatomía & histología , Exposición por Inhalación , Exposición Profesional , Movimientos del Aire , Contaminantes Ocupacionales del Aire , Humanos , Maniquíes , Modelos Biológicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA